China Ndgl Series 100A Load Isolation Switch, Find details about China Load Isolation Switch, Changeover Switch from Ndgl Series 100A Load Isolation Switch
Operation mode | ||
1 | Direct operation:The handle is installed directly in the middle of the switch. | |
2 | Operation outside the board:The handle is installed outside the door off distributing board. | |
3 | 63A-100A is suitable for the making and breaking of electrical isolation circuit or electric insulation. | |
4 | 63A-100A posseses three poles,and four poles(three poles+on off neutral pole.) | |
5 | Two sets of auxiliary contacts can be assembled according to demand. | |
6 | Side operation,operation outside,the board can be assemble according to demand. | |
Operation load isolation switch behind the HGL-160A~1600A/H board | ||
1 | 160A-1600A is stuitable for the making and breaking of electricl isolation circuit or electric insulation.Those over In 1,000A are only suitable for electric isolation. | |
2 | 160A-1600A possesses three poles, and four poles(three poles+on -off neutral pole). | |
3 | Observation window for products below 630A can be provided according to the demand to observe directly the on and off state of the contact. | |
4 | Two sets of auxiliary contacts can be assembled according to demand. | |
5 | Mechanical property and electric property correspond to the mechanical property and electric property of HGL-160A~1600A. | |
Note | only offer products for operation outside the board. | |
Connection load isolation switch behind HGL-160A~1600A/B board. | ||
1 | 160A-1600A is suitable for the making and breaking of electric isolation.Over In 1,000A are only suitable for electric isolation. | |
2 | 160A-1600A has three poles,and four poles(three poles+on-off neutral pole). | |
3 | Observation window for products below 630A can be provided according to the demand the on and off state of the contact. | |
4 | Two sets of auxiliary contacts can be assembled according to the demand. | |
5 | Mechanical performance and electric performance correspond to the mechanical property and electric property of SGL-160A~1600A. | |
NDGLC-160A~1600A side operation load isolation switch | ||
1 | HGLC-160A~1600A.The load isolation switch is suitable for the making and breaking of circuit or electric isolation.The products have three pole,four pole(three poles+on-off neutral pole)Switches over1000A are only suitable for Electric isolation. | |
2 | Observation window can be provided for products below 630A can be provided according to the demand to observe directly the on and off state of the contact. | |
3 | Mode of operation: Direct operation:handle is installed on the right side of switch. | |
Operation outside the board:handle is installed outside the door of distributing board. | ||
4 | Two sets of auxiliary contacts can be assembled according to the demand. | |
5 | Extended shaft is used for the operation outside the board. | |
6 | Mechanical property and electric performance correspond to the mechanical performance and electric perfomance of HGLC-160A~1600A. | |
7 | The electric cable insulating cover can be assembled. | |
NDGLZ-125A~1600A change over load isolation switch | ||
1 | HGLZ-125A~1600A.The load isolation switch is suitable for the change-over of two sets of low voltage electric circuit or the change-over of 2 set of load devices or safety isolation. | |
2 | Mode of operation: | |
Direct operation: handle is installed on the switch. | ||
Operation outside the board: handle is installed outside the door of power distributing board | ||
3 | Products with observation windows can be provided according to the demand to observe directly the ON and OFF state of contact. | |
4 | The products have three poles,four poles, and(three pole+ON and OFF neural pole). | |
5 | Extended shate is used for there operation outside the board. | |
6 | Two sets of auxiliary contacts can be assembled according to the demand. | |
7 | Mechanical performance and electric property correspond to the mechanical performance and electric property of HGL-125A-1600A. | |
8 | A bridge can provided to connect the inlet or outlet terminal of the switch. | |
9 | the electric cable insulating cover can be assembled | |
Note | The bridge connection is chosen, an explanation is needed to indicate there indicate the inlet or outlet connected with it |