2021 China Manufacture Automatic External Defibrillator Aed7000

2016 China Manufacture Automatic External Defibrillator Aed7000, Find details about China Defibrillator, Defibrillator Price from 2016 China Manufacture Automatic External Defibrillator Aed7000

Model NO.
AED700
Logo Printing
Customizable
Group
Adult
Feature
Reusable
Item Name
Defibrillator
Output
Biphasic Truncated Exponential
Biphasic Truncated Exponential
150, 150, 200j
Analysis Time
9 Sec.
Audible Prompts
22 Audible Prompts
Visual Prompts
Visual Prompts
Controls
Two Buttons-on/off, Shock
Weight
2.0kg
Operating Temperature
0°c to 40°c
Trademark
MSL
Transport Package
Standard Export Packing
Specification
4kg, 43*25*32cm
Origin
China (Mainland)
HS Code
9018199000
Model NO.
AED700
Logo Printing
Customizable
Group
Adult
Feature
Reusable
Item Name
Defibrillator
Output
Biphasic Truncated Exponential
Biphasic Truncated Exponential
150, 150, 200j
Analysis Time
9 Sec.
Audible Prompts
22 Audible Prompts
Visual Prompts
Visual Prompts
Controls
Two Buttons-on/off, Shock
Weight
2.0kg
Operating Temperature
0°c to 40°c
Trademark
MSL
Transport Package
Standard Export Packing
Specification
4kg, 43*25*32cm
Origin
China (Mainland)
HS Code
9018199000
Automatic External Defibrillator AED7000

Specifications
1.AED 
2.Two-button operation, lock-out protection 
3.Biphasic energy output 
4.External voice and visual prompt 
5.CE, ISO13485
 
Automatic External Defibrillator Features:
1. Three-step defibrillation process
2. Two-button operation
3. Extensive voice and visual prompts for the operator
4. Biphasic energy output
5. Lock-out protection to prevent inadvertent defibrillation
6. Continuous event recording for reporting each use to a printer or computer
7. Weekly self-test to ensure readiness
 
AED Specification:
Defibrillator
OutputBiphasic Truncated Exponential
Energy Sequence150, 150, 200J
Charge Time8 sec. to 150J; 10 sec. to 200J (New Battery)
Analysis Time9 sec.
The maximum time from the initiation of rhythm analysis to readiness for discharge with a new battery 
Less than 30 seconds
The maximum time from the initiation of rhythm analysis to readiness for discharge after 6 shocksLess than 35 seconds
The maximum time from initially switching power on to readiness for dischargeLess than 25 seconds
Audible Prompts22 audible prompts
Visual PromptsLED prompts
ControlsTwo buttons-ON/Off, Shock
Output Energy Accuracy±15% into any impedance from 25 to 175Ω
The Maximum Voltage1200±50V
Output disabled when the patient impedance is outside limits20Ωto 200Ω
 
Battery
Part No.CR123A-4*2
Non-rechargeable12V DC, 2.8Ah
CapacityAt 150 Joules
 
Physical
Dimensions303*216*89mm
Weight2.0kg
Operating Temperature0°C to 40°C
 
Operating Humidity
Relative humidity between 30% and 95% (non-condensing)
Storage Temperature (without battery)-20°C to 55°C
Storage Humidity (without battery)Up to 95% (non-condensing)