Ccw 413kVA China Factory Price Generator Set Diesel with Long Life, Find details about China Diesel Generator, Power Generator Set from Ccw 413kVA China Factory Price Generator Set Diesel with Long Life
Diesel Genset Features P.F=0.8 3Phase | ||||||||||
Generating Set Performance | 50Hz | |||||||||
Service | P.R.P | Standby | ||||||||
Rated output | kVA | 413 | 450 | |||||||
Active power output | kW | 330 | 360 | |||||||
Rated Speed | r.p.m | 1500 | ||||||||
Standard Voltage | V | 400/230 | ||||||||
Voltage available | V | 380/220 - 415/240 | ||||||||
Perforemance data refer to Standard Reference Conditions of ISO 8528:+25ºC,100m ALT,relative humidity 30% | ||||||||||
Power reduction acc.to DIN ISO 3046 Standard values:Above 100m ALT approx.1% per 100m.Above 25ºC(77ºF) approx.4% per 10ºC(50ºF). | ||||||||||
Considering cos phi=0.8 | ||||||||||
Prime Mover Performance 1500 r.p.m | ||||||||||
SERVICE | P.R.P | Standby | ||||||||
Rated output | KW | 377 | 407 | |||||||
Manufacturer | Cummins | |||||||||
4 stroke Diesel Engine - Injection type | Direct | |||||||||
Aspiration type | Turbocharged&Air-Air Cooled | |||||||||
Cylinders,number and arrangement | 6 -L | |||||||||
Bore×Stroke | mm | 140X152 | ||||||||
Total Displacement | L | 14 | ||||||||
Cooling system | Water | |||||||||
Emission Certification | N.A | |||||||||
Compression ratio | 14:1 | |||||||||
Specific fuel consumption(P.R.P) | L/h | 90,8 | ||||||||
Specific oil consumption(at full load) | % | <0.1 | ||||||||
Total coolant capacity | L | 60,6 | ||||||||
Fuel System | Type | Direct Injection Cummins PT(E) | ||||||||
1.P.R.P. Prime Power - ISO 8528:PRIME POWER is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals.The permissible average power output during a 24 hours period shall not exceed 80% of the prime power.10% overload available for governing purposes only. | ||||||||||
2.Max Standby power -ISO 3046 Fuel Stop power:Power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100% load 25h per year ,90% load 200h per year. No overload available. Applicable in case of failure of the main in areas of reliable electrical network. | ||||||||||
Synchronous Generator GTL | ||||||||||
Model | K360G4 | |||||||||
Poles | num | 4 | ||||||||
Winding Conections (standard) | Star-serie | |||||||||
Insulation | class | H | ||||||||
Enclosure(according to IEC-34-5) | IP23 | |||||||||
Phases | 3+N | |||||||||
Votage Regulators | A.V.R (SX440) | |||||||||
Steady voltage precision | within±1.0% from no load to full loading with cosΦ=0.8-1.0 | |||||||||
Alternator used by GTL Gensets meet the requirements of following Standard:BS5000,VDE0530,NEMA MG1-32,IEC34,CA C22.2-100,AS1359 | ||||||||||
Generationg Set Installation Data 1500 r.p.m | ||||||||||
EXHAUST SYSTEM | ||||||||||
Exhaust Gas Temperature at full load | ºC | 440 | ||||||||
ºF | 824 | |||||||||
Exhaust gas flow | L/s | 1153 | ||||||||
Maximum allowed back pressure | Kpa | 10 | ||||||||
AIR REQUIREMENT | ||||||||||
Air requirement for combustion at 100% load/rated speed | L/s | 511 | ||||||||
ft3/min(CFM) | 1082,1 | |||||||||
ELECTRIC STARTING SYSTEM | ||||||||||
Standard Battery Charging System | A | 35 | ||||||||
Minimum Recommended Battery Capacity-Cold Soak @ 0 °F (-18 °C) | CCA | 900 | ||||||||
Auxiliary voltage | V | 24 | ||||||||
LUBRICATION SYSTEM | ||||||||||
Lube oil system including sump,filters,etc. | L | 38,6 |