(MS-380D) Portable Monophasic Defi-Monitor Biophasic Cardiac Aed Defibrillator

China (MS-380D) Portable Monophasic Defi-Monitor Biophasic Cardiac Aed Defibrillator, Find details about China Defibrillator, Biophasic Defibrillator from (MS-380D) Portable Monophasic Defi-Monitor Biophasic Cardiac Aed Defibrillator

Model NO.
MS-380D
Anesthesia
None
Type of Operating Light
None
G.W
1.8 Kg
N.W
1.2 Kg
Trademark
customized
Transport Package
1 Piece in Carton
Specification
390*310*640mm
Origin
China
HS Code
9018193010
Model NO.
MS-380D
Anesthesia
None
Type of Operating Light
None
G.W
1.8 Kg
N.W
1.2 Kg
Trademark
customized
Transport Package
1 Piece in Carton
Specification
390*310*640mm
Origin
China
HS Code
9018193010

(MS-380D) Portable Monophasic Defi-Monitor Biophasic Cardiac Aed Defibrillator


MS-380D Biophasic Defibrillator

 

Physical characteristics:

Main unit: Portable

Dimensions:L320xW205xH410

Weight:9.5kg

 

Technical specifications

Defibrillator

(1)Defibrillator type Manual, Synchronized, Asynchronized,

(2)Out put waveform Biphasic technology

(3)Energy accuracy ∠+1%

(4)Energy selection 0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)

(5)Charging time Maximum 8 seconds to 360 Joules

(6)Standard Adult/Pediatric Paddles Reusable external adult paddles(pediatric paddles integrated)

 

Power requirements.

(a)AC Power supply 110V, 60 Hz /220V,50 Hz

(b)Vehicle Voltage DC 12V

 

Internal Battery Backup

(1)Battery type Rechargeable lead-acid battery

(2)Charging time Time-Minimum of 4 hours for full charging

(3)Battery charging During AC Power Supply operation of the device.

(4)Charging /Low Battery Indication Red LED

(5)Battery Capacity 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.

 

Display

-LED Dimensions 7'diagonal {155mm*88mm} which is easily read from a distance.

-Type High resolution true-color graphic LED

-Resolution 480X234

- Provide cardioversion facilities with waveform annotated on the screen

- Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.

- Display prompts, waveform settings, battery status, event summary and fault codes. Energy selected is displayed by push button under the screen.

 

ECG

ECG lead: I, II, III  AVR, AVL, AVF, V1~V6, GND 
S-T segment analysis: -2.0~2.0mv 
Arrhythmia analysis: yes 
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

 

Respiration

Measurement method: Thoracic impedance

 

Standard parameter & configuration

ECG/ RESP/DEFIBRILLATOR

-Provide audible and visual alarms for heart rate violations, VF and VT. 
-Provide a strip printer which annotates waveforms, events, time code
-Have a 5-lead patient cable as an option to a 3-lead cable. 
-Supplied with external re-usable paddles and packs of paper rolls for the printer.