China Dzl Dzh Horizont Electric Automatic Coal Biomass Wood Pellet Chips Firewood Fired Chain Grate Stoker Industrial Industry Coal /Biomass Fired Hot Water Boiler, Find details about China Hot Water Boiler, Biomass Fired from Dzl Dzh Horizont Electric Automatic Coal Biomass Wood Pellet Chips Firewood Fired Chain Grate Stoker Industrial Industry Coal /Biomass Fired Hot Water Boiler
Boiler Model | DZL1.4-0.7/95/70-AII | DZL2.8-0.7/95/70-AII | DZL4.2-1.0/ 115/70-AII | DZL5.6-1.0/ 115/70-AII | DZL7.0-1.0/ 115/70-AII | DZL14-1.25/ 115/70-AII | |||
Rated Evaporation Capacity | MW | 1.4 | 2.8 | 4.2 | 5.6 | 7.0 | 14 | ||
Operation Pressure | Mpa | 0.7 | 0.7 | 1.0 | 1.0 | 1.0 | 1.25 | ||
Steam Temperature | ºC | 95 | 95 | 115 | 115 | 115 | 115 | ||
Water-inlet Temperature | ºC | 70 | 70 | 70 | 70 | 70 | 70 | ||
Boiler Heating Efficiency | % | ≥76.6 | ≥78.8 | ≥79 | ≥82 | ≥82 | ≥83 | ||
Area of Stoker | M2 | 3.04 | 5.14 | 7.4 | 11.4 | 11.4 | 20.8 | ||
Coal Available | II type bitumite, low heat capability:17700-21000KJ/kg | ||||||||
Water Pump | Model | IS80-65-160 | IS100-80-160 | IS125-100-200 | IS125-100-200 | IS125-100-200 | IS125-100-250 | ||
Motor Power | KW | 7.5 | 15 | 30 | 45 | 55 | 75 | ||
Blast Fan | Model | G6-41-13 NO5.4A | G6-41-13 NO6.4A | G6-41-13 NO7.1A | G6-41-13 NO8.5A | G6-41-13 NO8.5A | TG20-1 | ||
Ventilation | m3/h | 4358-2310 | 7358-3596 | 10354-5394 | 18137-9369 | 18137-9367 | 32079 | ||
Wind Pressure | Pa | 994-1254 | 1181-1436 | 1697-2270 | 2535-3391 | 2535-3391 | 2559 | ||
Motor Power | KW | 3 | 5.5 | 7.5 | 18.5 | 18.5 | 37 | ||
Induced Draft Fan | Model | Y6-41-13 NO5.4C | Y6-41-13 NO7.1C | 1Y6-41-13 NO10C | Y6-41-13 NO11.2D | Y6-41-13 NO11.2D | GY20-15 | ||
Ventilation | m3/h | 8901-4350 | 15219-8171 | 32144-16607 | 41773-21578 | 41773-21578 | 73308 | ||
Wind Pressure | Pa | 2568-3240 | 2454-3283 | 2574-3444 | 2764-3697 | 2764-3697 | 3515 | ||
Motor Power | KW | 11 | 22 | 37 | 45 | 55 | 110 | ||
Dimensions of Biggest Parts for Shipment | M | 5.82×2.26×3.22 | 6.51×2.6×3.52 | 7.5×2.9×3.5 | 7.1×3.2×3.5 | 7.5×3.2×3.5 | 9.1×2.4×3.55 | ||
Weight of Biggest Parts for Shipment | T | 19 | 28 | 35 | 37 | 40 | 30 |
Boiler Model | SZL4.2-1.0/ 95/70-AII | SZL5.6-1.0/ 95/70-AII | SZL7.0-1.0./ 115/70-AII | SZL10.5-1.25/ 115/70-AII | SZL14-1.25/ 130/70-AII | ||
Rated Evaporation Capacity | MW | 4.2 | 5.6 | 7.0 | 10.5 | 14 | |
Operation Pressure | Mpa | 1.0 | 1.0 | 1.0 | 1.25 | 1.25 | |
Steam Temperature | ºC | 95 | 95 | 115 | 115 | 130 | |
Water-inlet Temperature | ºC | 70 | 70 | 70 | 70 | 70 | |
Heating Efficiency | % | ≥80 | ≥80 | ≥80 | ≥81 | ≥82 | |
Area of Stoker | M2 | 7.15 | 8.6 | 11.72 | 16.4 | 18.9 | |
Coal Available | II type bitumite,low heat capability:17700-21000KJ/kg | ||||||
Water Pump | Model | IS125-100- 200 | IS125-100- 200 | IS125-100- 250 | IS125-100- 250 | IS200-150- 315 | |
Motor Power | KW | 30 | 45 | 55 | 75 | 75 | |
Blast Fan | Model | G6-41-13 NO7.1A | G6-41-13 NO8.5A | G6-41-13 NO8.5A | TG15-1 | TG20-1 | |
Ventilation | m3/h | 5349-10354 | 9369-18137 | 9369-18137 | 23000 | 32079 | |
Wind Pressure | Pa | 1697-2270 | 2535-3391 | 2535-3391 | 1960 | 2559 | |
Motor Power | KW | 7.5 | 18.5 | 18.5 | 22 | 37 | |
Induced Draft Fan | Model | Y6-41-13 NO10C | Y6-41-13 NO11.2D | Y6-41-13 NO11.2D | TY15-2 | GY20-15 | |
Ventilation | m3/h | 32144- 16604 | 41773- 21578 | 41773- 21578 | 40000 | 73308 | |
Wind Pressure | Pa | 2575-3444 | 2764-3697 | 2764-3697 | 3038 | 3515 | |
Motor Power | KW | 37 | 45 | 45 | 75 | 110 | |
Dimensions of Biggest Parts for Shipment | M | 7.62×3.27× 3.46 | 8.82×3.34× 3.46 | 8.0×3.5×2.7 | 9.05×3.35× 3.69 | 10.6×3.35× 3.69 | |
Weight of Biggest Parts for Shipment | T | 31 | 45 | 28 | 24 | 27 |