Iceman Concrete Batch Plant Uses Water Chiller

China Iceman Concrete Batch Plant Uses Water Chiller, Find details about China Chiller, Industrial Chiller from Iceman Concrete Batch Plant Uses Water Chiller

Model NO.
PL-1~PL-20
Compressor Number
1
Noise Level
Low
Application Fields
Concrete Cooling
Application Machine
Machining Center
Certification
ISO, CE
Condition
New
Refrigerant
R22/R404A/R507
Trademark
ICEMAN
Transport Package
Wooden Cases/Container
Specification
40HQ Container
Origin
China
HS Code
8418692090
Model NO.
PL-1~PL-20
Compressor Number
1
Noise Level
Low
Application Fields
Concrete Cooling
Application Machine
Machining Center
Certification
ISO, CE
Condition
New
Refrigerant
R22/R404A/R507
Trademark
ICEMAN
Transport Package
Wooden Cases/Container
Specification
40HQ Container
Origin
China
HS Code
8418692090
Low temperature brine chilling unit
Using spiral pole compressor with the characteristic of low abrasion and low power exhausted.
Evaporator uses anti-corosion calcium chloride white heat exchange tube with the feature of light and small.
The parameter list for low-temperature saltwater chiller
Major parameter for YSBLG series semi-closed spiral
Saltwater chiller(tk=40ºC/t0=-20ºC)
Major parameter for YSBLG series semi-closed spiral
Saltwater chiller(tk=40ºC/t0=-40ºC)
ModelRequired
cooling 
power(kw)
Input 
power(kw)
Capacity
(/h)
Diameter of 
water tube(mm)
ModelRequired 
cooling 
power(kw)
Input 
power(kw)
Capacity
(/h)
Diameter of 
water tube(mm)
YSBLG155-2076.431.619.580YSBLG155-4030.525.38.550
YSBLG175-2086.436.32280YSBLG175-4034.529.19.550
YSBLG235-20115.549.529.5100YSBLG235-4046.239.81350
YSBLG270-20133.253.534100YSBLG270-4053.243.81550
YSBLG295-20145.361.937125YSBLG295-4058.149.71680
YSBLG370-20182.475.446.5150YSBLG370-4072.960.52080
YSBLG445-20221.48856150YSBLG445-4088.570.524.580
YSBLG520-20261.4104.666.5150YSBLG520-40104.483.329100
YSBLG570-20286.6116.272.5200YSBLG570-40114.693.131.5100
YSBLG645-20324.3136.582200YSBLG645-40129.6109.535.5100
YSBLG700-20351.9148.189200YSBLG700-40140.6118.838.5100
YSBLG780-20392.4159.199.5200YSBLG780-40156.8127.443125
PS.Cooling power refers to refrigerant inlet and outlet temperature-10ºC/-15ºC;Cooling water inlet and outlet temperature 30ºC/35ºC;
The saltwater contains 25% cacl2;And outlet cooling saltwater is -15
ºC.
PS.Cooling power refers to refrigerant inlet and outlet temperature-30ºC/-35ºC;Cooling water inlet and outlet temperature 30ºC/35ºC;
The saltwater contains 28.5% cacl2;And outlet cooling saltwater is -15
ºC.
Iceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water ChillerIceman Concrete Batch Plant Uses Water Chiller