European Super Thin Design Floor Standing Exposed Fan Coil Unit
Floor mounted fan coil unit, Horizontal concealed fan coil unit, cassette fan coil unit, ceiling floor fan coil unit, wall mounted fan coil unit, ceiling suspended fan coil unit
1. Ultra-thin vertical exposed fan coil unit features:
(1)Ultra thin design,the thickness of fan coil unit is only 130mm.(see as below,less than IPHONE 5 length);
(2) Air return direction is selectable,side air return and bottom air return is optional,adjust to fit different environment;
(3) Air flow can becontrolled in a breeze status,very quiet; it is the best alernative to the radiator:
a. Radiators only offer heating,but our ultra thin fan coil unit can offer heating and cooling;
b.Radiators's heating speed is slow and radiation is narrow,inefficient air convection;Fan coil unit have higher heat exchange speed,therefore fan coil unit can create more uniform temperature field space.
(4)Standard design with inbuilt digital room thermostat.Without room thermostat is optional,user need prepare thermostat;
(5)Unit standard design is manual adjusting to air flow;auto swing is optional must with DC motor;
(6)Left or right water connection direction can be selected;
(7)Left and right side panels can be removed independently.It is easy for installation and maintenance;
(8)Easy-removable and washable filter was in-built.
In central air conditioner system, Eurostars ultra thin vertical exposed fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Vertical floor standing fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.
2. Eurostars Ultra-thin vertical exposed fan coil unit nomenclature
ES T 200 VE2 T R 0 A O
1 2 3 4 5 6 7 8 9
1: ES Eurostars
2 :T Terminal series
3 :200 Rated air flow: CFM
4 :VE2 Vertical exposed and the number of pipe system
5 :T Coil type: T-2C0H (Note: C-Cold water coil; H-Hot water coil)
6 :R Connection pipe direction: R-Right (face to air outlet) L-Left (face to air outlet)
7 :0 Built-in electrical heating power: 0-None;
8: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
9 :O Sales region: O-Other regions; C-Mainland China
3. Eurostars ultra thin fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
Vertical Exposed Fan Coil Unit(Ultra thin type) |
Model EST | 200VE2 | 300VE2 | 400VE2 | 500VE2 | 600VE2 |
Air flow (m³/h) | High | 200 | 300 | 400 | 500 | 600 |
Low | 80 | 120 | 180 | 220 | 260 |
Rated cooling capacity | W | 1000 | 1900 | 2800 | 3500 | 4000 |
BTU | 3413 | 6485 | 9556 | 11946 | 13652 |
Rated heating capacity(1) | W | 1500 | 2850 | 4200 | 5250 | 6000 |
BTU | 5120 | 9727 | 14335 | 17918 | 20478 |
Rated heating capacity (2) | W | 2000 | 3800 | 5550 | 6950 | 8000 |
BTU | 6826 | 12969 | 18942 | 23720 | 27304 |
Motor power input | W | 18 | 24 | 35 | 40 | 45 |
Noise | dB(A) | 30 | 32 | 36 | 38 | 40 |
Water flow | m3/h | 0.17 | 0.33 | 0.49 | 0.60 | 0.64 |
Water resistance | kPa | 12 | 14 | 18 | 20 | 24 |
Heat exchanger | Type | copper tubes with shutter-type aluminum fins |
Max. Working pressure | 1.6MPa |
Testing pressure | Airtightness test under pressurized water: 3.3MPa |
Pipe | Inlet/outlet water pipe | R1/2 "external thread |
Condensation water pipe | φ21 |
Dimensions(L*W*H) mm | 700*130*681 | 900*130*681 | 1100*130*681 | 1300*130*681 | 1500*130*681 |
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating1: Inlet air temperature DB 20°C, heating water inlet temperature 60°C
Heating2: Inlet air temperature DB 20°C, heating water inlet temperature 70°C
(tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.