5kVA/ 50kv Partial Discharge Measurement System

China 5kVA/50kv Partial Discharge Measurement System, Find details about China Lab Equipment, Hipot Tester from 5kVA/50kv Partial Discharge Measurement System

Model NO.
SYNY-0014JF
Partial Discharge
Under Rated Voltage≤5PC
No-Load Loss
0.2%-0.35%
Insulation Method
Oil, Gas
Allowed Continuous Operation Time
Once an Hour
Transport Package
Wooden Case
Origin
Shanghai, China
HS Code
9030339000
Model NO.
SYNY-0014JF
Partial Discharge
Under Rated Voltage≤5PC
No-Load Loss
0.2%-0.35%
Insulation Method
Oil, Gas
Allowed Continuous Operation Time
Once an Hour
Transport Package
Wooden Case
Origin
Shanghai, China
HS Code
9030339000

Application

Partial discharge test system is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.

Composition

It is consists of a PD free tested transformer (Oil immersed type or SF6 gas inflatable type), test console, digital PD detector, PD free isolation filter, PD free protection resistor, PD free coupling capacitor.
5kVA/50kv Partial Discharge Measurement System

Features

1.A variety of control methods and insulation methods can be used to configure freely according to user demand.
2.Build-in multiple frequency power generator is used for testing partial discharge value of high voltage transformer.The system has a built-in multi-frequency power generator which can be used to measure the discharge of high voltage transformer.
3.Manual control operation is intuitive, easy to use maintenance, low price.
4.It has gas insulation, transformer oil insulation, dry epoxy resin insulation and other forms test transformer, can choose and match according to user's demand.
5.According to the user's requirements, different sets of measuring instruments can be configured to meet the requirements of different precision and analysis faults.
6.Automatic control system can be used in different configurations of the bureau, and the results can be automatically detected and analyzed.

Technical specification

Rated Capacity5-1000kVAImpedance Voltage10%
Input VoltageAC 220V/AC 380VOutput Voltage WaveformPower frequency, sine wave
Output VoltageAC 0-1000kVSurface TemperatureOil immersed:<55ºC
Gas: <50ºC
Partial DischargeUnder rated voltage≤5PCNo-load Loss0.2%-0.35%
Insulation MethodOil, GasAllowed Continuous Operation TimeOnce an hour