China 30W Dual Output Switching Power Supply 5V 12V Output SMPS, Find details about China 30W Dual Output Switching Power Supply, 5V 12V Output SMPS from 30W Dual Output Switching Power Supply 5V 12V Output SMPS
SPECIFICATIONS | ||||
OUTPUT | ||||
Model | D-30A | D-30B | ||
Output number | CH1 | CH2 | CH1 | CH2 |
DC Voltage | 5V | 12V | 5V | 24V |
Rated Current | 4A | 1A | 2.2A | 1A |
Current Range | 0.5-4A | 0.1-1A | 0.5-2.2A | 0.1-1A |
Rated Power | 32W | 35W | ||
Ripple & Noise | 50mVp-p | 100mVp-p | 50mVp-p | 100mVp-p |
Voltage Adj. Range | CH1: -5%, +10% | CH1: -5%, +10% | ||
Voltage Tolerance | ±2% | +3%,-7% | ±2% | +3%,-5% |
Setup,Rise,Hold Up Time | 200ms,50ms,30ms at full load | |||
INPUT | ||||
Voltage Range | 85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC | |||
AC Current | 0.8A/115V 0.45A/ 230V | |||
Efficiency | 72% | 74% | ||
Inrush Current | Cold start 18A/115V 36A/230V | |||
Leakage Current | <1mA/240VAC | |||
PROTECTION | ||||
Over Load | 105%~150% | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
ENVIRONMENT | ||||
Working Temp., Humidity | -10ºC~+60ºC; 20%~90%RH | |||
Storage Temp., Humidity | -20ºC~+85ºC; 10%~95%RH | |||
Temp. Coefficient | ±0.03%/ºC(0~50ºC) | |||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||
SAFETY | ||||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||
STANDARD | ||||
Safety Standard | Design refer to UL1012 | |||
EMC Standard | Design refer to FCC Part15 J Conduction Class A | |||
OTHERS | ||||
Dimension | 129*98*38mm(L*W*H) | |||
Weight | 0.41Kg | |||
Packing | 45pcs/19Kg/1.2CUFT | |||
NOTE | ||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |