80t Counter Flow Closed Loop Cooling Tower Lkm-80

China 80t Counter Flow Closed Loop Cooling Tower Lkm-80, Find details about China Closed Cooling Tower, Closed Circuit Cooling Tower from 80t Counter Flow Closed Loop Cooling Tower Lkm-80

Model NO.
NWM-150
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Water Capacity
150m3/H
Inlet/Outlet Temperature
37/32c
Air Volume
62000m3/H
Fan Power
4kw
Inlet/Outlet Pipe Size
DN100
Circulating Pump Power
2.2kw
Circulating Water Flow
65m3/H
Net/Operation Weight
4060kg/5100kg
Case Material
Galvanized Steel Plate
Coil Material
Cooper
Trademark
NEWIN
Transport Package
Wood Packing
Specification
CE, UL, CTI
Origin
Shenzhen China
HS Code
84195000
Model NO.
NWM-150
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Water Capacity
150m3/H
Inlet/Outlet Temperature
37/32c
Air Volume
62000m3/H
Fan Power
4kw
Inlet/Outlet Pipe Size
DN100
Circulating Pump Power
2.2kw
Circulating Water Flow
65m3/H
Net/Operation Weight
4060kg/5100kg
Case Material
Galvanized Steel Plate
Coil Material
Cooper
Trademark
NEWIN
Transport Package
Wood Packing
Specification
CE, UL, CTI
Origin
Shenzhen China
HS Code
84195000
NWN series closed circuit cooling tower (counter flow), with fills-less design, Cooling process occurred between air and coil. Which makes cooling tower more compact and system more simple compare to cross flow closed circuit cooling tower. 


Operation Principle80t Counter Flow Closed Loop Cooling Tower Lkm-80

Fresh air take into cooling tower from air inlet grid at the bottom part.Ascending fresh air meets the falling hot water , formation of saturated humid air. The saturated air discharged by the top axial cooling fan. During discharging the saturated air, water in the air is keep back by the drift eliminator, and falling back to bottom basin. Newin counter flow closed circuit cooling tower adopts fill-less design, saved lots of space for installing more coil cooler. Compacted structure small space occupied. Especially suite for working condition that output temperature not far from the wet bulb temperature.
Characteristics
 

Large Internal Space

Humanized structure design, large access door, interior space is capacious, the maintenance personnel can easily finish maintenance works in side cooling tower.

Non-stop Maintenance

The maintenance work to floating ball valve and filter net can be processed during cooling tower continuous working status.

Excellent heat exchange performance

Fills less design, saves space for more coil cooler. Increased the heat exchanging area.

Smaller wind resistance

Because cooling system does not have film fill. Greatly reduced the air resistance. Save power and better ventilation performance.

Simple maintenance work

Fills-less design, makes system more simple, No need to clean and replace the film fill.

Smaller occupied area

80t Counter Flow Closed Loop Cooling Tower Lkm-80
A compacted structure makes occupied area much smaller.

Model
Cooling
 Capacity

(KW)
FanSpray pumpWeight (kg)Dimension  (mm)
Power
(Kw)
Power
(kw)
Net Running   L     W   
NWN-35350.550.37 4508001480+3009002550
NWN-50500.750.37 600950
NWN-60600.750.37 7201100
NWN-90900.55*20.37 185033002000+30011502500
NWN-1201200.55*20.75 21003500
NWN-1501500.75*20.75 235038002500+35011502650
NWN-1801801.5*20.75 27504500
NWN-2302301.5*20.75 295050003000+35014002660
NWN-2902902.2*21.10 31505500
NWN-3503503.0*21.10 33506000
NWN-4004004.0*21.10 355063003500+35014003200
NWN-4504504.0*21.50 41506800
NWN-5005004.0*22.20 515073003500+40022003910
NWN-6006005.5*22.20 55507800
NWN-7507505.5*22.20 605085004000+40022004050
NWN-8508507.5*23.00 712010500
NWN-100010007.5*24.00 715095004500+40030004250
NWN-1150115011*24.00 772011500
NWN-130013007.5*25.50 8300127005400+40030004550
NWN-1450145011*25.50 1068014600


Easy maintenance
Huge space of maintenance, to provide the convenience of transformational for equipment maintenance, maintenance person can go through the access door into the tower

80t Counter Flow Closed Loop Cooling Tower Lkm-80
80t Counter Flow Closed Loop Cooling Tower Lkm-8080t Counter Flow Closed Loop Cooling Tower Lkm-80
80t Counter Flow Closed Loop Cooling Tower Lkm-80
80t Counter Flow Closed Loop Cooling Tower Lkm-80