Office Building Hotel Use 1-32 Zones Fire Alarm Panel

China Office Building Hotel Use 1-32 Zones Fire Alarm Panel, Find details about China Fire Alarms, Fire Alarm Control Panel from Office Building Hotel Use 1-32 Zones Fire Alarm Panel

Model NO.
AW-CFP2166
Transmission Mode
Cable
Alarm Volume (within 1m)
≥100dB
Receive Frequency
Wire
Optional Extendable Zones
1-32 20 Detectors/Zone Max.
Power Supply
220VAC
Backup Battery
24VDC
Exterior Housing
Metal Material
Housing IP Grade
IP56
Optional Housing Color
Grey/Red/Black/White
Wire Structure
2-Wire Bus
Wire Connection
Series Connection Max.2km Long
Alarm Alert
Front LCD Panel with LED Indicator
OEM/ODM
Available
Trademark
Asenware
Transport Package
Seawhorty & Airworthy Package
Specification
CE, LPCB
Origin
Guangdong, China
HS Code
853110000
Model NO.
AW-CFP2166
Transmission Mode
Cable
Alarm Volume (within 1m)
≥100dB
Receive Frequency
Wire
Optional Extendable Zones
1-32 20 Detectors/Zone Max.
Power Supply
220VAC
Backup Battery
24VDC
Exterior Housing
Metal Material
Housing IP Grade
IP56
Optional Housing Color
Grey/Red/Black/White
Wire Structure
2-Wire Bus
Wire Connection
Series Connection Max.2km Long
Alarm Alert
Front LCD Panel with LED Indicator
OEM/ODM
Available
Trademark
Asenware
Transport Package
Seawhorty & Airworthy Package
Specification
CE, LPCB
Origin
Guangdong, China
HS Code
853110000
Office Building Hotel Use 1-32 Zones Fire Alarm Panel



Uganda-installed Hotel 4 Zones Fire Alarm Panel
Introductions:
1. AW-CFP2166-16 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
2. Adopted modularized design, flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.


Asenware, professional fire alarm solution provider.
ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panel
Model No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32
Power specification
 
Mains supply voltage110VAC or 240VAC
Internal power supply27.2VDC
Total output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VAC
Main supply monitor for faultYes
Battery protection for low voltageYes
Batteries (default configuration)12V2AH*2
Detector circuit specification
 
Number of circuit124-164-32
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Line fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zoneNo limit
Sounder circuit specification
 
Number of general circuits2
End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Outputs fused AT400mA
Maximum number of bells @ 20mA of each sounder output20
Fuses
 
Battery fuse1.5A F 20mm
Sounder outputs500mA F 20mm
Fire and fault output
 
Output typeNC and NO relay
Maximum current100mA
Connection block
 
Largest acceptable conductor size2.5mm2
Smallest acceptable conductor size0.75mm2
Size and weight
 

 
Dimensions(mm)272*200*70mm320*231*90mm395X502X124362X565X124
Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg9.6kg12.5kg