Laboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem Samples

China Laboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem Samples, Find details about China Twin-Jet Electropolisher, Electrolytic Polisher from Laboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem Samples

Injection Volume of Electrolyte
500ml
Light Sensing Value Range
0-800
Liquid Pump Speed Regulation
0-99 Level
Sample Clip
Suitable for Diameter 3mm Standard Sample
Trademark
CYKY
Transport Package
Standard Export Wooden Box Packaging
Origin
Zhengzhou Henan China
HS Code
8412800090
Injection Volume of Electrolyte
500ml
Light Sensing Value Range
0-800
Liquid Pump Speed Regulation
0-99 Level
Sample Clip
Suitable for Diameter 3mm Standard Sample
Trademark
CYKY
Transport Package
Standard Export Wooden Box Packaging
Origin
Zhengzhou Henan China
HS Code
8412800090
laboratory Electropolisher electrolytic polisher with double spray for thinning TEM samples


Introduction of Twin-Jet Electropolisher:
CY-TJ100-SE Twin-Jet Electropolisher is a kind of metal electron microscope sample preparation equipment with touch screen control, visualization and intelligence, and can accurately control the temperature of independent cooling source. The equipment has the advantages of storage and transfer of preparation parameters, good sample preparation effect and high repeatability. Tj100-se electrolytic double spray thinning instrument is suitable for thinning TEM samples in Colleges and research institutes. It is easy to operate and easy to use. It is an indispensable sample thinning equipment in TEM laboratory.

Features of Twin-Jet Electropolisher:
Touch screen man-machine interface: TJ100-SE adopts 7-inch full-color touch screen control, easy to operate and simple to use. Good man-machine interface design, intuitive data, real-time display of electrolyte temperature and current curve.

Parameter storage and recall function: The polishing voltage, pump flow speed, photosensitive stop value, recommended temperature and electrolyte name set for each operation can be named, stored and recalled at any time.

Unique voltage scanning function: the metal sample can be scanned in a selected range of voltage changes to obtain the anode polarization curve of the metal, and the appropriate polishing voltage can be selected on the polarization curve.

Stable performance and durability: liquid transmission of corrosion-resistant gear pump, advanced PLC control, subdivided pump flow speed and light sensor stop value, good sample preparation repeatability. The electrolytic cell is separated from the control part to minimize the influence of the corrosive medium on the control part. The electrolytic cell is divided into an inner tank and a lower shell, and the double-layer protection has better insulation and cooling effects.

Independent cooling source cooling control: using independent low temperature circulation cold pump cooling control, directly setting the temperature on the touch screen, establishing a second constant temperature field in the electrolytic cell, and performing constant temperature control, which greatly improves the repeatability of sample preparation.

Easy to replace corrosion-resistant sample holder: specially designed sample holder, built-in platinum electrode and pressing device, rotating shaft clamp cover to press and fix the sample, easy to load and take pieces. The segmented design at the bottom avoids the siphon effect. Independent light-weight sample holder for easy replacement.

Technical parameters of Twin-Jet Electropolisher:
Technical parameter1. Power input: AC220V/50Hz, 600W

2. Liquid nitrogen cooling temperature control: ≥-55ºC

3. Cooling temperature control of the cooler: ≥-30ºC±1C (external option)

4. Electrolysis voltage: 0-220V

5. Electrolysis current: 0-1000mA

6. Injection volume of electrolyte: 500ml

7. Light sensing value range: 0-800

8. Liquid pump speed regulation: 0-99 level

9. Sample clip: suitable for φ3mm standard sample
Optional accessoriesThe specific parameters are as follows:

1. Liquid tank volume 5L

2. Coolant Ethanol

3. Circulation mode Internal and external circulation

4. Liner size Φ20*20cm

5. Maximum flow rate 15L/min

6. Cooling capacity 1600W@20ºC

7. No-load refrigeration -35ºC

8, size 640*450*890mm

9. Temperature control accuracy is less than ±1ºC

10. Weight 40Kg

11. Set the temperature on the touch screen, use the circulating cold pump to output refrigerant liquid, control the temperature, and cool the electrolyte through the cold coil to establish the second constant temperature field.
Product specification1.Insulation box size: 325mm(W)240mm(D)*170mm(H)

2. Size of electrolytic cell: 180mm(w*150mm(D)*50mm(H)

3.Control box size: 290mm(w)250mm(D)*180mm(H)

Related photos of Twin-Jet Electropolisher:
Laboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem Samples



Laboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem Samples

Founded in 2005, Zhengzhou CY Scientific Instrument Co., Ltd. is a company specializing in the development and production of laboratory technology research equipment. The products are mixed, pressed, burned, cut, ground, polished, coated, analytical equipment and related consumables. Products include laboratory sintering equipment, coating equipment and so on. At present, it has been exported to 25 countries and regions such as the United States, Europe, and Southeast Asia, and has been well received by various scientific research units.

We have a mature technology research and development team, the number of technicians is 33, the company has 150 people, more than 500 square meters of office space, the factory covers an area of about 1,500 square meters located in Zhengzhou High-tech Zone Electronic Industrial Park. The products are mainly located in the research market, serving scientific research in the labs of universities and colleges, and can also customize products according to your needs.

Laboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem Samples
Laboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem SamplesLaboratory Electropolisher Electrolytic Polisher with Double Spray for Thinning Tem Samples

Q. Are you a manufacturer or a trading company?

A. We are professional laboratory instrument manufacturers, have their own design team and factory, have mature technical experience, and can guarantee the quality of products and the optimal price.

Q. How is your company's product after-sales service system?

A. The product warranty period is 12 months, we can provide lifetime maintenance. We have professional pre-sales and after-sales departments that can respond to you within 24 hours to resolve any technical issues.

Q. How long is your delivery time? If I want to customize the instrument, how long does it take?

A.1. If the goods are in stock, it is 5-10 days. 2. We can provide customized services for our customers. It usually takes 30-60 days depending on the specifications of the custom instrument.

Q. Our country's power supply and plug are different. How do you solve it?

A. We can supply a transformer and plug according to your local requirements according to the power plug of different countries.

Q. How to pay?

A.T / T, L / C, D / P, etc., it is recommended to use Alibaba Trade Guarantee.

Q. How is the package of goods? Delivery methods?

A.1. Standard export fumigation sign wooden box packaging 2. Express, air, sea shipping according to customer requirements, find the most suitable way.

More questions, please contact customer service.