UL Listed 5X7 Feet Hotel 2 Hours Fire Rated Exit Door Steel Fire Door

China UL Listed 5X7 Feet Hotel 2 Hours Fire Rated Exit Door Steel Fire Door, Find details about China 30min Fire Door, Fire Exit Door from UL Listed 5X7 Feet Hotel 2 Hours Fire Rated Exit Door Steel Fire Door

Model NO.
XZ- ST
Position
Exterior
Security Rating
A
Surface Finishing
Finished
Function
Fire Proof
Trademark
XUNZHONG
Transport Package
Export Standard Wooden Packing
Specification
2520 mm*2520 mm
Origin
Shanghai
HS Code
7308300000
Model NO.
XZ- ST
Position
Exterior
Security Rating
A
Surface Finishing
Finished
Function
Fire Proof
Trademark
XUNZHONG
Transport Package
Export Standard Wooden Packing
Specification
2520 mm*2520 mm
Origin
Shanghai
HS Code
7308300000

UL Listed 5X7 Feet Hotel 2 Hours Fire Rated Exit Door Steel Fire Door
Product Specifications
UL Listed 5x7 Feet Hotel 2 Hours fire rated exit door steel fire door
BrandXunzhong
CertificationsUL NUM(R39532/R39533)
Filler MaterialHoney Core, Mineral rock wool, polyurethane core.
Fire rated time1 hour up to 3 hours.
SizeMaximum size is (2530x2530mm)  
Door leaf sheet22 Ga. - 18 Ga. (0.8/1.0/1.2 mm)galvanized steel/cold roll steel
Door frame sheet16 Ga. - 14 Ga. (1.5mm-2.0mm). cold roll steel/galvanized steel
Surface finishDoor leaf and frame powder coated finish.
Frame depth115mm - 240mm
OpeningSwing Inward / Outward
ColorRAL color system, could be customized as well.
AccessoriesLock,handle,hinges,door closer,panic bar and other as requested.
Vision PanelWith or without as requested.
Lite FrameUL listed lite frame. (UL Number: 39534)
LouverWith or without as requested.
FeatureFire proof and thermal insulation.
ApplicationSuitable for building project, business, home decoration(Office, hotel, church, home and so on.)
Packagewooden pallets
MOQ1 Set

UL Listed 5X7 Feet Hotel 2 Hours Fire Rated Exit Door Steel Fire Door
UL Listed 5X7 Feet Hotel 2 Hours Fire Rated Exit Door Steel Fire Door
UL Listed 5X7 Feet Hotel 2 Hours Fire Rated Exit Door Steel Fire Door
 

FAQ
Q1: Are you a manufacturer of fire doors?

A:Yes ,we are. Offering excellent and various goods at competitive price is what we have been keeping doing.

Q2: What kind of Certification did you pass?

A: After relevant institution of professional evaluation, we're qualified for UL, CE, ISO9001, BV, ROHS, etc.
For wooden fire doors, we are qualified for BS-476, EN-1634, UL-10C.


Q3: How can you guarantee your final quality?

A: As for quality control, we've approved four testing procedures: 
Initial inspection, re-inspection, final inspection and sampling inspection.


Q4: How is the MOQ of required?

A: We welcome any amount under your requested. but a competitive price is always depends on the quantity increase gradually.

Q5: How long is the production lead time?

A: Usually, T/T 50% deposit to start production, the balance paid before shipping. Lead time about 15-25 days.

Fire Door Info

The fire resistance door panel and the fire resistance door frame must pass the guidelines of a testing agency that provides the product listing. The door frame is composed of the fire or smoke seals, door hardware, and the structure that holds the fire door in place. These components form an assembly called a doorset which holds a numerical rating - the number of hours of resistance to test fire. All components must have a listing agency label to ensure that they have been tested to pass the fire rating requirements.So Shanghai XunZhong Company has pass UL listed for Steel fire doors in 1,2,3hours issued by UL company directly.Also we have UL certification for wooden doors up to 2 hours . More importantly,our certification could hold glass panel.
Fire doors are not always noncombustible. Some portions of the door may be destroyed by combustion during exposure to fire; this is acceptable as long as the door assembly passes the fire test criteria of limiting temperature on the non-fire side of the assembly.
The goal of the fire door is to slow down the spread of fire from one compartment to another for a limited amount of time enough for occupants to evacuate. Fire doors create a protected route to safety, assist the fire brigade and withstand the attack of fire for a limited time.
Nonetheless, occupants are not always protected from smoke and fire by the fire doors. Poorly maintained and incorrectly installed fire doors pose a great risk to the occupants of the building and may result in fatal injuries. Fire doors must be properly installed to reduce the risk of failure; gaps must be appropriately filled with fire-resisting sealant. Also, it is important that they are regularly inspected by a professional to ensure safety.
For additional information, contact XunZhong today and protect your hotel ,home, office or business from the dangers of fire outbreaks. We service throughout North American offering a complete fire protection service including supply, installation, testing, servicing, and maintenance. When it comes to protecting your family, staff, customers, and property from fire, Xunzhong has the right advice, products, and services.