China Manufacturer Portable PT Vt CVT Transformer Analyzer

China Manufacturer Portable PT Vt CVT Transformer Analyzer, Find details about China CT Analyzer, Vt Analyzer from China Manufacturer Portable PT Vt CVT Transformer Analyzer

Model NO.
PTA-2000C
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Top
Power Supply
220V 50Hz
Voltage Output
180V
Size
365 mm*290mm*153mm
Manufacturer
Kvtester
Trademark
KvTester
Transport Package
Aluminum Alloy Packing Box Inside Andwooden Box O
Origin
China
HS Code
9031809090
Model NO.
PTA-2000C
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Top
Power Supply
220V 50Hz
Voltage Output
180V
Size
365 mm*290mm*153mm
Manufacturer
Kvtester
Trademark
KvTester
Transport Package
Aluminum Alloy Packing Box Inside Andwooden Box O
Origin
China
HS Code
9031809090

Product Description

 

China Manufacturer Portable PT Vt CVT Transformer Analyzer

PTA-2000 PT analyzer is a comprehensive test instrument based on transformer volt ampere characteristics ratio regulator, analysis error of comprehensive test instrument transformer volt ampere characteristics of series resonant polarity ratio, widely listen to the views of users, through a new generation of innovative PT test equipment R & D after extensive market research, in-depth theoretical research.

Device adopts high performance DSP+FPGA and ARM industrial computer, advanced manufacturing technology, to ensure stable and reliable product performance, complete functions, high degree of automation, high testing efficiency, in the domestic leading level, is professional testing instrument for transformer in electric power industry.
 

Product Features

1: Single instrument can realize the error test of voltage transformer, no need of resonance booster device, standard voltage transformer, load box, check instrument and other equipment, greatly reducing the workload of the field calibration error.

2: The test range is wide, can test the voltage level of 6kV~800kV electromagnetic voltage transformer.

3: Using internal 0.01 level standard voltage transformer, low voltage transformer error measuring by difference test method, and using different frequency measurement technology, nonlinear error of PT conversion 50Hz, finally get the error of transformer. Instrument test level can reach 0.05 level. During the testing process, the maximum generation of test voltage is not more than 3kV, to ensure the safety of the field test.

4: The test wiring ,operation is simple and easy to learn, just according to the guide prompt operation can easily complete transformer calibration work greatly improve the test efficiency. Test time is short, less than 5 minutes.

5: The software algorithm is accurate, the accuracy of measurement data to further improve the intelligent judgment connection status, prompt connection error, wrong polarity ratio, etc..

6: Automatic test data for the whole, and to determine whether the ultra poor, super bad data using anti black display, the data characteristics of the mutual inductor intuitive and clear.

7: Large memory can store the test data of up to 10000.

8: The use of aluminum chassis, with good anti-interference, and to ensure the safety of the operation personnel and equipment safety in the field of high voltage test.

9: Using high resolution and large size 8 inch true color liquid crystal display, outdoor strong light under the clear display, with touch screen auxiliary operation, simple and quick, full Chinese display operation, easy to understand.

Product Parameters

 

Power Supply
Voltage range200VAC~240VAC
Allowable voltage range180VAC~260VAC
Frequency50Hz/60Hz
Allowable frequency range45Hz~65Hz
Input powerStandby: 80VA  Rated test power:600VA  Peak power:1800VA
Output
High voltage output0~3000VAC
Low voltage output0~120VAC,0~120VDC
Output current0~5A eff(15A peak)
Output power0~600VA eff(1500VA peak)
Electromagnetic voltage transformer(VT)
Ratio testRatio:1~350  Voltage level: 0.6kV~35kV Typical accuracy:0.05%
Ratio:350~2450 Voltage level: 35kV~245kV Typical accuracy:0.05%
Phase error testRatio:1~350  Voltage level : 0.6kV~35kV Typical accuracy:1min
Ratio:350~2450  Voltage level: 35kV~245kV Typical accuracy:2min
Capacitor voltage transformer(CVT/CCVT)
Ratio testRatio:300~8000 Voltage level: 30kV~800kV Typical accuracy:0.07%
Phase error testRatio:300~8000 Voltage level: 30kV~800kV  Typical accuracy:2min
Coil resistance measurement
Resolving power1mΩ
Typical accuracy0.05%
Guaranteed accuracy0.1% + 1mΩ
Load test
Resolving power0.02VA
Typical accuracy0.05%
Guaranteed accuracy0.1% + 0.02VA
Size
Volume700mm*590mm*350mm
Weight15kg ( No accessories included)
Environment condition
Working temperature-10ºC~50ºC
Storage temperature-25ºC~70ºC
Relative humidity5%~95%,No condensation


 

Our Advantages

 

China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer
China Manufacturer Portable PT Vt CVT Transformer Analyzer