China 1200W 1400W MPPT Solar Grid Tie Micro Inverter 24V 110V 220V Microinverter Inversor Regulator 50Hz 60Hz for on Grid Solar System, Find details about China Solar Inverter, Micro Inverter from 1200W 1400W MPPT Solar Grid Tie Micro Inverter 24V 110V 220V Microinverter Inversor Regulator 50Hz 60Hz for on Grid Solar System
1.Single unit connects to one PV module
2.Maximum 1200W AC output power
Product Series | SG1200 Series | |||
Model | SG1200MQ (Regular) | SG1200MT (Custom-made) | SG1200HT (Custom-made) | |
Input Data(DC,PV) | ||||
Number of Input MC4 Connector | 4 set | 3 set | 3 set | |
MPPT Voltage Range | 24V-40V | 24V-40V | 36V-60V | |
Operation Voltage Range | 18V-50V | 18V-50V | 30V-70V | |
Maximum Input Voltage | 50V | 50V | 70V | |
Startup Voltage | 18V | 18V | 30V | |
Maximum Input Power | 4*300W | 3*400W | 3*400W |
|
Maximum Input Current | 4*12A | 3*16A | 3*11.1A | |
Output Data(AC) | ||||
Single-Phase Grid Type | 120V & 230V | |||
Rated Output Power | 1150W | |||
Maximum Output Power | 1200W | |||
Nominal Output Current | @120VAC : 9.58A / @230VAC : 5A | |||
Nominal Output Voltage | 120VAC / 230VAC | |||
Default Output Voltage Range | @120VAC : 80V-160V / @230VAC : 180V-280V | |||
Nominal Output Frequency | 50Hz / 60Hz | |||
Default Output Frequency Range | @50Hz : 47.5Hz-52.5Hz / @60Hz : 57.5Hz-62.5Hz | |||
Power Factor | >0.99 | |||
Total Harmonic Distortion | THD <5% | |||
Maximum Units per Branch | @120VAC : 4 units / @230VAC : 8 units | |||
Efficiency | ||||
Peak Efficiency | 95% | |||
CEC Weighted Efficiency | @120VAC : 92.5% / @230VAC : 93.5% | |||
Nominal MPPT Efficiency | 99.9% | |||
Night Power Consumption | <700mW | |||
Mechanical Data | ||||
Operating Ambient Temperature Range | -40°C to +65°C | |||
Storage Temperature Range | -40°C to +85°C | |||
Dimensions (W x H x D) | 250mm x 230mm x 38mm (not include connectors and cable) | |||
Weight | 2.5kg | |||
Max Current of AC Bus Cable | 40A | |||
Waterproof Grade | IP65 | |||
Cooling Mode | Natural Convection - No Fans | |||
Other Features | ||||
Communication(Inverter to DataBox) | 2.4G Wireless | |||
Transformer Design | High Frequency Transformers, Galvanically Isolated | |||
Integrated Ground | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | |||
Protection Functions | Isolated Island Protection, Voltage Protection, Frequency Protection, Temperature Protection, Current Protection, etc. | |||
Design Compliance | NB/T32004:2013,NB/T32004:2013,EN61000-3-2,EN62109,VDE0126,UL1741 etc. |
1400w Parameter Table
Product Series | SG1400 Series | |
Model | SG1400MQ (Regular) | SG1400HQ (Custom-made) |
Input Data(DC,PV) | ||
Number of Input MC4 Connector | 4 set | 4 set |
MPPT Voltage Range | 24V-40V | 36V-60V |
Operation Voltage Range | 18V-50V | 30V-70V |
Maximum Input Voltage | 50V | 70V |
Startup Voltage | 18V | 30V |
Maximum Input Power | 4*350W | 4*350W |
Maximum Input Current | 4*14A | 4*9.7A |
Output Data(AC) | ||
Single-Phase Grid Type | 120V & 230V | |
Rated Output Power | 1350W | |
Maximum Output Power | 1400W | |
Nominal Output Current | @120VAC : 11.25A / @230VAC : 5.86A | |
Nominal Output Voltage | 120VAC / 230VAC | |
Default Output Voltage Range | @120VAC : 80V-160V / @230VAC : 180V-280V | |
Nominal Output Frequency | 50Hz / 60Hz | |
Default Output Frequency Range | @50Hz : 47.5Hz-52.5Hz / @60Hz : 57.5Hz-62.5Hz | |
Power Factor | >0.99 | |
Total Harmonic Distortion | THD <5% | |
Maximum Units per Branch | @120VAC : 3 units / @230VAC : 6 units | |
Efficiency | ||
Peak Efficiency | 95% | |
CEC Weighted Efficiency | @120VAC : 92.5% / @230VAC : 93.5% | |
Nominal MPPT Efficiency | 99.9% | |
Night Power Consumption | <700mW | |
Mechanical Data | ||
Operating Ambient Temperature Range | -40°C to +65°C | |
Storage Temperature Range | -40°C to +85°C | |
Dimensions (W x H x D) | 250mm x 230mm x 38mm (not include connectors and cable) | |
Weight | 2.5kg | |
Max Current of AC Bus Cable | 40A | |
Waterproof Grade | IP65 | |
Cooling Mode | Natural Convection - No Fans | |
Other Features | ||
Communication(Inverter to DataBox) | 2.4G Wireless | |
Transformer Design | High Frequency Transformers, Galvanically Isolated | |
Integrated Ground | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | |
Protection Functions | Isolated Island Protection, Voltage Protection, Frequency Protection, Temperature Protection, Current Protection, etc. | |
Design Compliance | NB/T32004:2013,NB/T32004:2013,EN61000-3-2,EN62109,VDE0126,UL1741 etc. |