China 600W 700W Micro Solar Panel Smart Inverter Pure Sine Wave Home Inversor 30V 36V MPPT on Grid Tie Inversor IP65 for 110V 220V, Find details about China Solar Inverter, Micro Inverter from 600W 700W Micro Solar Panel Smart Inverter Pure Sine Wave Home Inversor 30V 36V MPPT on Grid Tie Inversor IP65 for 110V 220V
Feature:
1.Single unit connects to one PV module
2.Maximum 600W AC output power
Product Series | SG600 Series | ||
Model | SG600MD (Regular) | SG600HD (Custom-made) | SG600TD (Custom-made) |
Input Data(DC,PV) | |||
Number of Input MC4 Connector | 2 set | 2 set | 2 set |
MPPT Voltage Range | 24V-40V | 36V-60V | 80V-115V |
Operation Voltage Range | 18V-50V | 30V-70V | 70V-120V |
Maximum Input Voltage | 50V | 70V | 120V |
Startup Voltage | 18V | 30V | 70V |
Maximum Input Power | 2*300W | 2*300W | 2*300W |
Maximum Input Current | 2*12A | 2*8.3A | 2*3.7A |
Output Data(AC) | |||
Single-Phase Grid Type | 120V & 230V | ||
Rated Output Power | 590W | ||
Maximum Output Power | 600W | ||
Nominal Output Current | @120VAC : 5A / @230VAC : 2.6A | ||
Nominal Output Voltage | 120VAC / 230VAC | ||
Default Output Voltage Range | @120VAC : 80V-160V / @230VAC : 180V-280V | ||
Nominal Output Frequency | 50Hz / 60Hz | ||
Default Output Frequency Range | @50Hz : 47.5Hz-52.5Hz / @60Hz : 57.5Hz-62.5Hz | ||
Power Factor | >0.99 | ||
Total Harmonic Distortion | THD <5% | ||
Maximum Units per Branch | @120VAC : 4 units / @230VAC : 8 units | ||
Efficiency | |||
Peak Efficiency | 95% | ||
CEC Weighted Efficiency | @120VAC : 92.5% / @230VAC : 93.5% | ||
Nominal MPPT Efficiency | 99.9% | ||
Night Power Consumption | <700mW | ||
Mechanical Data | |||
Operating Ambient Temperature Range | -40°C to +65°C | ||
Storage Temperature Range | -40°C to +85°C | ||
Dimensions (W x H x D) | 185mm x 180mm x 38.5mm (not include connectors and cable) | ||
Weight | 1.5kg | ||
Max Current of AC Bus Cable | 20A | ||
Waterproof Grade | IP65 | ||
Cooling Mode | Natural Convection - No Fans | ||
OtherFeatures | |||
Communication(Inverter to DataBox) | 2.4G Wireless | ||
Transformer Design | High Frequency Transformers, Galvanically Isolated | ||
Integrated Ground | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | ||
Protection Functions | Isolated Island Protection, Voltage Protection, Frequency Protection, Temperature Protection, Current Protection, etc. | ||
Design Compliance | NB/T32004:2013,NB/T32004:2013,EN61000-3-2,EN62109,VDE0126,UL1741 etc. |
Product Series | SG700 Series | ||
Model | SG700MD | SG700HD | SG700TD |
(Regular) | (Custom-made) | (Custom-made) | |
Input Data(DC,PV) | |||
Number of Input MC4 Connector | 2 set | 2 set | 2 set |
MPPT Voltage Range | 24V-40V | 36V-60V | 80V-115V |
Operation Voltage Range | 18V-50V | 30V-70V | 70V-120V |
Maximum Input Voltage | 50V | 70V | 120V |
Startup Voltage | 18V | 30V | 70V |
Maximum Input Power | 2*350W | 2*350W | 2*350W |
Maximum Input Current | 2*14A | 2*9.7A | 2*4.3A |
Output Data(AC) | |||
Single-Phase Grid Type | 120V & 230V | ||
Rated Output Power | 650W | ||
Maximum Output Power | 700W | ||
Nominal Output Current | @120VAC : 5.4A / @230VAC : 2.8A | ||
Nominal Output Voltage | 120VAC / 230VAC | ||
Default Output Voltage Range | @120VAC : 80V-160V / @230VAC : 180V-280V | ||
Nominal Output Frequency | 50Hz / 60Hz | ||
Default Output Frequency Range | @50Hz : 47.5Hz-52.5Hz / @60Hz : 57.5Hz-62.5Hz | ||
Power Factor | >0.99 | ||
Total Harmonic Distortion | THD <5% | ||
Maximum Units per Branch | @120VAC : 4 units / @230VAC : 7 units | ||
Efficiency | |||
Peak Efficiency | 95% | ||
CEC Weighted Efficiency | @120VAC : 92.5% / @230VAC : 93.5% | ||
Nominal MPPT Efficiency | 99.90% | ||
Night Power Consumption | <700mW | ||
Mechanical Data | |||
Operating Ambient Temperature Range | -40°C to +65°C | ||
Storage Temperature Range | -40°C to +85°C | ||
Dimensions (W x H x D) | 185mm x 180mm x 38.5mm (not include connectors and cable) | ||
Weight | 1.5kg | ||
Max Current of AC Bus Cable | 20A | ||
Waterproof Grade | IP65 | ||
Cooling Mode | Natural Convection - No Fans | ||
Other Features | |||
Communication(Inverter to DataBox) | 2.4G Wireless | ||
Transformer Design | High Frequency Transformers, Galvanically Isolated | ||
Integrated Ground | Equipment ground is provided by the PE in the AC cable. No additional ground is required. | ||
Protection Functions | Isolated Island Protection, Voltage Protection, Frequency Protection, Temperature Protection, Current Protection, etc. | ||
Design Compliance | NB/T32004:2013,NB/T32004:2013,EN61000-3-2,EN62109,VDE0126,UL1741 etc. |