China 200kw DC 480V off Grid Three Phase Wind Power Inverter, Find details about China Wind Turbine Inverter, Wind Generator Inverter from 200kw DC 480V off Grid Three Phase Wind Power Inverter
Type | SHJ-NBQ200K-T380 | SHJ-NBQ200K-T480 | |
DC input | Input rated voltage | 380 VDC | 480 VDC |
Input rated current | 584.4 A | 463.3A | |
Input DC voltage allowing range | 320-500 VDC | 400-620 VDC | |
AC input (AC bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC | |
Input rated current | 550A / 300A / 290A | ||
Bypass transfer time | ≤100ms(4ms optional) | ||
AC output | Rated capacity | 200KVA | |
Output rated power | 160KW | ||
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | ||
Output rated current | 550A / 300A / 290A | ||
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 2% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Wave | Pure sine wave (Isolation transformer) | ||
THD. | ≤3%(Linear load) | ||
Power factor (PF) | 0.8 | ||
Overload capacity | 120%,10 minutes | ||
Overcurrent capacity | 200%,10 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | >95% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10ºC~+50ºC | ||
Humidity | 0~90%, No condensation | ||
Altitude | <2000m Higher than 2000m rated power should be reduced | ||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
Pure Sine Wave | Yes | ||
Equipped With Copper Transformer | Yes | ||
Solar Charger | Optional | ||
AC Charger | Optional | ||
Generator Port | Optional | ||
Size | 1280*2000*2060mm | ||
Weight | 2000 kg |
Type | SHJ-NBQ400K-T480 | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 694.4A | |
Input DC voltage allowing range | 400-620 VDC | |
AC input (AC bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 830A / 450A / 430A | |
Bypass transfer time | ≤100ms(4ms optional) | |
AC output | Rated capacity | 300KVA |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | |
Output rated current | 830A / 450A / 430A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 2% | |
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |
Wave | Pure sine wave (Isolation transformer) | |
THD. | ≤3%(Linear load) | |
Power factor (PF) | 0.8 | |
Overload capacity | 120%,10 minutes | |
Overcurrent capacity | 200%,10 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | >96% | |
Working Environment | Dielectric strength | 1500VAC,1 minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -10ºC~+50ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <2000m Higher than 2000m rated power should be reduced | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
Pure Sine Wave | Yes | |
Equipped With Copper Transformer | Yes | |
Solar Charger | Optional | |
AC Charger | Optional | |
Generator Port | Optional | |
Size | 1280*2000*2060mm | |
Weight | 2500 k |
Type | SHJ-NBQ500K-T480 | |
DC input | Input rated voltage | 480 VDC |
Input rated current | 1157A | |
Input DC voltage allowing range | 400-620 VDC | |
AC input (AC bypass) | Allow input voltage range | 220 VAC / 380 VAC / 400 VAC ± 15% VAC |
Input rated current | 1380A / 760A / 725A | |
Bypass transfer time | ≤100ms(4ms optional) | |
AC output | Rated capacity | 500KVA |
Output rated voltage and frequency | 220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz | |
Output rated current | 1380A / 760A / 725A | |
Output voltage accuracy | 220 VAC / 380 VAC / 400 VAC ± 2% | |
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | |
Wave | Pure sine wave (Isolation transformer) | |
THD. | ≤3%(Linear load) | |
Power factor (PF) | 0.8 | |
Overload capacity | 120%,10 minutes | |
Overcurrent capacity | 200%,10 seconds | |
Crest factor (CF) | 3:1 | |
Inverter efficiency | >96% | |
Working Environment | Dielectric strength | 1500VAC,1minute |
Noise (1m) | ≤50dB | |
Ambient temperature | -10ºC~+50ºC | |
Humidity | 0~90%, No condensation | |
Altitude | <2000m Higher than 2000m rated power should be reduced | |
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | |
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | |
Pure Sine Wave | Yes | |
Equipped With Copper Transformer | Yes | |
Solar Charger | Optional | |
AC Charger | Optional | |
Generator Port | Optional | |
Size | 2150*1400*2300mm | |
Weight | 2600 kg |