Bromine Br2 Gas Detector Sensor 200 ppm Air Quality Monitoring Disinfectant Petrochemical Toxic Electrochemical Gas Slim

China Bromine Br2 Gas Detector Sensor 200 ppm Air Quality Monitoring Disinfectant Petrochemical Toxic Electrochemical Gas Slim, Find details about China Membrapor, Br2 Detector from Bromine Br2 Gas Detector Sensor 200 ppm Air Quality Monitoring Disinfectant Petrochemical Toxic Electrochemical Gas Slim

Model NO.
Cl2/S-200-S
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
TTL/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
FAD
Transport Package
Transparent Plastic Box
Specification
41mm
Origin
China
HS Code
8542330000
Model NO.
Cl2/S-200-S
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
TTL/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
FAD
Transport Package
Transparent Plastic Box
Specification
41mm
Origin
China
HS Code
8542330000
Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning.
 
Gas Module Feature
- Long lifetime imported advanced electrochemical sensors
- High accuracy op ams, power supply IC, stable and sensitive
- Detect low or high concentration toxic gases precisely
- High anti-interference ability
- Over range protection, reversed polarity protection and lightning protection
- Low power consumption with a standard 4-20mA two/three-wire signal output
- Interface: pump, diffusing, flange, flange thread types
- 12-36VDC operating voltage


Bromine Br2 Gas Detector Sensor 200 ppm Air Quality Monitoring Disinfectant Petrochemical Toxic Electrochemical Gas SlimBromine Br2 Gas Detector Sensor 200 ppm Air Quality Monitoring Disinfectant Petrochemical Toxic Electrochemical Gas SlimBromine Br2 Gas Detector Sensor 200 ppm Air Quality Monitoring Disinfectant Petrochemical Toxic Electrochemical Gas Slim
Sensor Performance Characteristics
Nominal Range
0 - 200 ppm
Maximum Overload
400 ppm
Expected Operation Life
2 years in air
Output Signal
- 140± 35 nA/ppm
Resolution 1 ppm
Temperature Range
- 20 °C to 45 °C
Pressure Range
Atmospheric±10%
Pressure Coefficient
No data
Relative Humidity Range
15 % to 90 % R.H.non condensing
Typical Baseline Range (pure air, 20°C)
< 0.7 ppm
Maximum Zero Shift (+20°C to +40°C)
- 1.5 ppm
Long Term Output Drift
< 2 % signal loss/month
Recommended Load Resistor 10-33 Ohm
Bias Voltage
Not recommended
Repeatability < 2 % of signal
Output Linearity
Linear
T80 Response Time
< 90 sec

Sensor Physical Characteristics
Weight~ 27 g
Position SensitivityNone
Storage LifeSix months in container
Recommended Storage Temperature5 °C - 20 °C
Warranty Period12 months from date of dispatch


Bromine Br2 Gas Detector Sensor 200 ppm Air Quality Monitoring Disinfectant Petrochemical Toxic Electrochemical Gas Slim
Module Parameters
Module typeGM-I2(3)-M/C/S-**-****/G/P/F/FL
Detected gasToxic gas
Detecting principleElectrochemistry
SamplingDiffusing  pump  flange  thread
Responding time30s~40s(of the sensor)
Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)
Module repeatability≤±2% FS
Module linear error≤±2% FS
Module zero temperature drift≤±2% (FS/year)
Module operating temperature-40~80°C
Module humidity0-95%RH(non-condensation)
Sensor operating temperature-20°C~50°C
Sensor humidity0-90%RH(non-condensation)
Signal outputTTL/4-20mA /RS485   (two or three wire)
Transmitting distance1000 meters(RS485)
Operating voltageDC 12-36V
Maximum power≤0.8W
Size80*48mm
Explosion proofIntrinsic safe
Connection cableRVVP3 x 1.5mm²

Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control, portable gas detector