China GDSF-311WPD SF6 gas dew point tester, Find details about China Gas Analyzer, sf6 gas purity tester from GDSF-311WPD SF6 gas dew point tester
Application
Measuring range | Dew point -100 ~ +30 ºC(support ppmv, etc. ). |
Dew point accuracy | +-0.5degree (when the dew point temperature is below 0 degree, the sensor output for the frost point). |
Repeatability | +-0.5 degree. |
Gas flow | SF6 adjustment in 0.5 ~ 0.9L/min; |
Measuring range | 0 ~ 100% SF6 |
Accuracy and repeatability | +-0.5%, nothing to do with the flow |
SF6 Humidity | |
Measurement method | Resistive and Capacitive measurement principle |
Ambient temperature | -20ºC--+60ºC |
Measurement range | dew point -80ºC--+20ºC(support ppmv) (when the dew point temperature is below 0 ºC, the sensor output is the frost point) |
Accuracy | ±1ºC |
Response time | 63% [90%] +20→-20ºC Td 5s[45s] -20→-60ºC Td 10s[240s] |
Resolution | 0.01ºC |
Repeatability | ± 0.5 ºC |
Display unit | ºC, ppm, ºCP20(converted value at 20ºC) |
Gas flow | 400-600ml/min |
Flow display | 0-1000mL digital flow meter |
Sample gas pressure | ≤1MPa |
SF6 Purity | |
Measurement method | Infrared measurement principle (European sensor company NDIR series sensor) |
Ambient temperature | -20ºC--+60ºC |
Measuring range | 0 ~ 100% SF6. |
Response time | [90%] 60s |
Measurement error | ±0.5%FS |
Repeatability error | ±0.5% |
Resolution | 0.01% |
Display unit | % |
SF6 Decomposition Products | |
Measuring method | Principle of electrochemical measurement (Swiss Mombas wave electrochemical series sensor) |
Ambient temperature | -20ºC--+60ºC |
Measurement range | SO2: 0~200PPmv H2S: 0~200PPmv CO : 0~500PPmv HF : 0~50PPmv |
Measurement error | SO2 <10PPmv : ±0.3PPmv >10PPmv : ±3% H2S <10PPmv : ±0.3PPmv >10PPmv : ±3% CO <50PPmv : ±2PPmv >50PPmv : ±4% HF <10PPmv : ±0.3PPmv >10PPmv : ±3% |
Repeatability error | SO2 <10PPmv : ±0.2PPmv >10PPmv : ±2% H2S <10PPmv : ±0.2PPmv >10PPmv : ±2% CO <50PPmv : ±2PPmv >50PPmv : ±2% HF <10PPmv : ±0.2PPmv >10PPmv : ±2% |
Resolution | 0.01PPmv |
Display unit | PPmv |
Other Features | |
Power supply | 220VAC±10%, 50Hz, AC/DC use, over-charge protection, continuous working is no lower than 8hours. |
Ambient temperature | -20--+60ºC |
Environment humidity | 90%RH |
Gas flow | 400 ~ 600ml / min |
Flow rate display | 0~1000mL imported digital flowmeter |
Sample gas pressure | ≤1MPa |
Measurement value influence | No effect of pressure and flow |
Dimension | 395*295*155mm |
Weight | about 2kg |