Model NO.
MCA-A20
Ventilation
Electronically Controlled& Pneumatically Driven
Driven Gas
O2(Air: Optional)
Tidal Volume Range
15 ~1500 Ml
Pressure Range (Limit)
10~100 CMH2o
Pressure Range (Support)
3~60CMH2o
Respiratory Rate
4~100bpm
Inspiratory /Expiratory Ratio (I: E) Ra
4:1~1:10
Apnea I: E
4:1~1:8
Apnea Time
10~30s
Apnea Pressure
3~60CMH2o
Inspiratory Pause
off, 5~16% of Inspiratory Time
Trademark
MeCan
Transport Package
Carton
Specification
1.76cbm
Origin
Guangzhou
Model NO.
MCA-A20
Ventilation
Electronically Controlled& Pneumatically Driven
Driven Gas
O2(Air: Optional)
Tidal Volume Range
15 ~1500 Ml
Pressure Range (Limit)
10~100 CMH2o
Pressure Range (Support)
3~60CMH2o
Respiratory Rate
4~100bpm
Inspiratory /Expiratory Ratio (I: E) Ra
4:1~1:10
Apnea I: E
4:1~1:8
Apnea Time
10~30s
Apnea Pressure
3~60CMH2o
Inspiratory Pause
off, 5~16% of Inspiratory Time
Trademark
MeCan
Transport Package
Carton
Specification
1.76cbm
Origin
Guangzhou
Anesthesia Machine
MCA-A20
High-Quality and Double-Duty Anesthesia Machine Replace Ventilator
Technical Specification
Physical Characteristics 
Size 773.5mm×1380mm×598mm
Weight90kg
Entire Machine Maximum Bearing Weight

160kg
Screen Size:8.4" TFT touch screen
Resolution800 × 600
Handrail Length412mm
Caster wheel4 wheels 4" brakes;
Operation Environment 
Working Temp 10~40°C
Humidity ≤93%
Power Supply100-240V~, 50/60Hz±1Hz
Battery Type  Rechargeable Lithium-ion battery
Battery Capacity4400mAh, 11.1VDC
Battery Recharging Time
Maximum 10 hours for charging
Battery backup 2 hours for continuous working
TraceWaveforms: Pressure-time; Flow rate-time; Capacity-time; ET EtCO2 concentration; EEG
Optional: Pressure-volume Loops; Flow-volume Loops; Pressure- flow Loops
Top Plate 
Maximum supporting capacity
20kg
Operational dimensions
508mm×313mm
Dimensions with Additional Accessory
508mm×313mm×380mm
Workbench 
Maximum
supporting capacity

20kg
Operational dimensions
472mm×248mm
Dimensions with Additional Accessory
472mm×248mm×380mm
Interfacing:
 USB port
 RJ45
 Three auxiliary power output
 AC power interface
 Equal-potential grounding terminal
 DB9 interface
Features  
Drawers:Size:416mm×395mm×170mm
Bearing Weight: 1Kg
Gas-bag Sway Brace:Length: 320mm; Height: 240mm
Anesthesia processOpen, semi closed, closed circuit
PatientsDesigned for adult, pediatric
ModeManual, Mechanical, Standby
ComplianceCompliance Correction
ConfigurationPossibility of configuration observation
Optional Bypass; Heating; Oxygen sensor; ACGO; AGSS; BIS; CPB;
MASIMO EtCO2 (sidestream); MASIMO EtCO2 (mainstream); MASIMO AG (sidestream); Respironics EtCO2 (mainstream);
 
Ventilator Specification
Ventilation Modes
VCV/VCVolume-Controlled Ventilation with tidal volume compensation
OthersManual and automatic ventilation
OptionalPCV/VPC, SIMV-VC, PSV/ CPAP, SIMV-PC, PRVC, SIMV-PRVC, PSVPro
Ventilation principleChronometric, volumetric and barometric
VentilationElectronically controlled& pneumatically driven
Driven gasO2(air: optional)
Ventilator Setting ranges
Monitoring parameterTidal volume, Inspiratory, expiratory flow, minute volume, frequency, pressure (Pmean, Pplat, Ppeak, PEEP), Oxygen, CO2, N2O and halogenated expiratory concentration, Pressure, oxygen, CO2, N2O and Halogen numerical values, compliance and patient resistance
Tidal volume range15 ~1500 mL
Pressure range
(limit)

10~100 cmH2O
Pressure range
(support)

3~60cmH2O
Respiratory rate4~100bpm
Inspiratory
/Expiratory ratio
(I: E) range


4:1~1:10
Apnea I: E4:1~1:8
Apnea time10~30s
Apnea pressure3~60cmH2O
Inspiratory pauseOFF, 5~16% of inspiratory time
Inspiratory time0.2~5s
Inspiratory pressure5~70cmH2O
PEEPOFF, 3~30cmH2O
Trigger pressure-20~-1cmH2O
Trigger window5~90%
Trigger flow 0.2~15 L/ min 
Flush oxygen 25~75 L/ min
Inspiratory stop level5~80%
Pressure slope0~2.0s
Positive End Expiratory Pressure (PEEP) 
TypeIntegrated, electronically controlled
Range0~70 cmH2O
Ventilator Monitoring Ranges
TV (Inspiratory tidal volume)
0~3000 mL 
TV (Expiratory tidal volume)
0~3000 mL 
MV (Per-minute ventilation amount)
0~100 L/min
FiO2 (Oxygen concentration)
18~100%
Airway pressure-20~120cmH2O
PEEP0~70cmH2O
Ppeak
(Airway pressure)

-20~120 cmH2O
Pmean
(Mean pressure)

-20~120cmH2O
Pplat
(Platform pressure)

0~120cmH2O
I: E (Inspiratory- expiratory ratio)
4:1~1:12
Freq
(Respiratory rate)

0~120 bpm
Compl (Compliance)0~300 mL/cmH2O 
Resistance0~600 cmH2O/(s/L)
EtCO2 
MASIMO EtCO2 (sidestream); 0~190mmHg, 0~25% (at 760mmHg)
Accuracy: ± (0.3%+4% of reading).
MASIMO EtCO2 (mainstream)0~190mmHg, 0~25% (at 760mmHg)
Accuracy: ± (0.3%+4% of reading).
Respironics EtCO2 (mainstream)0~150mmHg, 0~19.7% (at 760mmHg)
Accuracy: 0~5.3%: ±0.3%;
5.4~9.2%: ±5% of reading;
9.3~13.2%: ±8% of reading;
13.3~19.7%: ±10% of reading;
AG
MASIMO AGSEV: 0~25%DES: 0~25%HAL/ ISO/ ENF: 0~25%
N2O: 0~100%
O2: 0~100%
CO2: 0~25% (0~190mmHg)
Accuracy:
SEV: 0~1%: ± 0.15%; 1~5%: ±0.2%; 5~8%: ±0.4%;
DES: 0~1%: ± 0.15%; 1~5%: ±0.2%; 5~10%: ±0.4%;10~15%: ± 0.6%; 15~18%: ±1%;
ISO, ENF, HAL: 0~1%: ±0.15%; 1~5vol %: ±0.2%; N2O: ± (2% + 2% of the reading)
O2: 0~25%: ±1%; 25~80%: ±2%; 80~100%: ±3%;
CO2: 0~15%: ± (0.2% + 2% of the reading); 15~25%: unspecified
Anesthesia depth 
BIS0.0~100.0
SQI0.0~100.0%
EMG0~100dB
ESR0.0~100.0%
Ventilator Performance
Pressure range at inlet0.28~0.6 MPa
Peak gas flow100 L/min plus fresh gas
Flow valve range1~100 L/min
Flow compensation rage
200 mL/min to 15 L/min
Inspiratory flowMaximum inspiratory flow shall not be smaller than 120L/min when gas supply pressure is 280KPa.
Range of flow valve3~100 L/min
Pressure limitation
Controlling means for ventilator
Controlled by the electronic relief valve fitted inside the ventilator;
Controlled by the mechanical relief valve fitted inside the ventilator.
  
Ventilator accuracy
Control accuracy
TV15~60 ml: ±10ml;
60~210 ml: ±15ml;   
210~1500 ml: ±7% of set value.
PCVInspiratory pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
Limiting pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
PEEP: OFF: undefined; 3~30cmH2O: ±2.0cmH2O, or ±8% of set value, whichever is the greater.
Supporting pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
Apnea pressure: ±2.5cmH2O or ±7% of set value, whichever the greater.
Trigger pressure: ±2.0cmH2O. 
Freq±1 bpm or ±5% of set value, whichever is the greater.
I: E 2: 1~1: 4: ±10% of reading value;
Other ranges: ±25% of reading value.
Apnea I: E 2: 1~1: 4: ±10% of set value;
Other ranges: ±25% of set value.
Tip: Ti20%~60%: ±15% of set value;
Other ranges: undefined.
Inspiratory time±0.2s
Inspiratory pause20%~60%: ±15% of set value;
Other ranges: undefined.
Trigger window±10%
Trigger flow rate ±1 L/ min 
Inspiratory stop level±10%
O2/ N2O/ Air flow control 10~100% of the full scale: ±10% of the reading value. Other ranges: undefined.
Total flow controlAir balance gas: ≤±3%
N2O balance gas: ≤±3%
Backup flow controlPure Oxygen flow rate is 0~10 L/min: ±3%; Others: undefined.
Auxiliary flow control10~100% of the full scale: ±10% of the reading value. Other ranges: undefined.
Monitoring accuracy
TV
(expiratory)
0~60ml: ±10 ml; 60ml ~ 3000ml: ± 20ml or ± 7% of reading value, whichever is greater; Others: undefined.
TV
(Inspiratory)
60ml ~ 3000ml: ± 20ml or ± 7% of reading value, whichever is greater; Others: undefined.
Paw -20 cmH2O~120 cmH2O: ±2.0 cmH2O or ± 4% of set value, whichever is greater; Others: undefined.
PEEP0 cmH2O~70 cmH2O: ±2.0 cmH2O or ± 4% of set value, whichever is greater; Others: undefined.
Pmean
 
-20 cmH2O~120 cmH2O: ±2.0 cmH2O or ± 4% of setting value, whichever is greater;
Others: undefined.
Pplat
 
0 cmH2O~120 cmH2O: ±2.0 cmH2O or ± 4% of set value, whichever is greater; Others: undefined.
Freq±1 bpm or ±5% of set value, whichever is the greater.
I: E 2: 1~1: 4: ±10% of reading value;
4: 1~2: 1 and 1: 4~1: 12: ±25% of setting value; Others: undefined.
MV 0 L/min~30 L/min: ±1 L/min or ±15% of set value, whichever is greater; Others: undefined.
Compliance 0 ml/cmH2O~250 ml/cmH2O: ±0.5 ml/cmH2O or ± 15% of reading value, whichever is greater;
Other ranges: undefined.
Resistance0 cmH2O/(L/s)~20 cmH2O/(L/s): ±10 cmH2O/(L/s);20 cmH2O/(L/s)~500 cmH2O/(L/s):±50% of reading value; Other ranges: undefined.
Oxygen sensor ±3%
O2/ N2O/ Air flow control 10~100% of the full scale: ±10% of the reading value. Other ranges: undefined.
Total flow controlAir balance gas: ≤±3%
N2O balance gas: ≤±3%
Backup flow controlPure Oxygen flow rate is 0~10 L/min: ±3%; Others: undefined.
Auxiliary flow control10~100% of the full scale: ±10% of the reading value. Other ranges: undefined.
Alarm Settings  
Tidal volume
(expiratory)

High: 5~1600 ml
 Low: 0 ~1595 ml
MVHigh: 2~100L/ml
 Low: 0 ~98L/ml
Inspired oxygenHigh: 20~105%
 Low: 18 ~ 103%
PpeakHigh: 2 ~100cmH2O
 Low: 0 ~98cmH2O
Apnea alarm30s
AlarmAudible and visual alarm;
Alarm accessEasy access by shortcut
Flow meters  
TypeMechanical flow meter
Gas Supply 
Pipeline gassesO2
OptionalO2, Air; O2, N2O; O2, N2O, Air
Standby
gas-cylinder gasses

O2, N2O, Air
Pipeline gas connection
NIST
Standby cylinder
connection

PISS 

Pressure range at inlet


280~600 kPa
Filter 60-80um
FeaturesSwitch easily to the other gas without interrupting the ventilation
Auxiliary gas supplyO2(optional)
  
Breathing Circuit Specification 
System Pressure Gauge 
Range-20~100 cmH2O
Accuracy± (4% of full scales reading + 4% of reading)
Adjustable Pressure Limiting (APL)valve
Range1~75 cmH2O
Tactile knob indication at
>30 cmH2O
Accuracy:±1.0 cmH2O
Minimum opening
pressure

0.3 cmH2O (dry), 0.5 cmH2O (humid)
Breathing Circuit Parameters
Compliance4mL/100Pa
Automatically compensates for compression loss with in the breathing circuit in mechanical mode
Volume of CO2 canister
1500ml
Water Trap7mL, easy to be disassembled
FeatureHeated at 134 degree, removable, easy to dismantle and sterilize
  
Gas Monitoring  
Carbon Dioxide (CO2) Modules 
TypeMainstream ETCO2, Sidestream ETCO2
MethodInfrared absorption
DisplayNumeric and curve displayed in screen
Alarm delay1~10s (step size: 1s)
Sweep6.25 mm/s,12.5 mm/s
Anesthetic Agent (AG) Module 
Maximum sound pressure for low alarm

79dB
Measurement typeSide stream
Module typePhasin ISA AG module
Accuracy±10ml/min or ±10%, whichever is greater
Monitored parametersCO2, N2O, AA, MAC, Paramagnetic O2 and BIS
Active AGSS 
FeatureHigh flow, low vacuum
Size 535mm×120mm×155mm
Weight2.2kg
Applies ISO 80601-2-13 and YY 0635-2
Pressure relief device Atmospheric pressure compensation port
Connector ISO9170-2 or BS6834 standard connector
Flow of suction 50-80L/min
Resistance 0.75KPa ,75L/min
FilterStainless steel mesh, with pore size of 60~100μm
ACGO
ConnectorTaper coaxial fitting of 22mm (outside) and 15 (inside)
Back pressure generated at the rear end of anesthesia vaporizer and the front-end of ACGO during quick oxygen charging
<=2kPa
Flush O2  
 100% fast oxygen
Vaporizer 
BrandDrager and Penlon available
LockingVaporizer with interlocking system (Optional: Two vaporizers)
Automatic recognitionAnesthesia machine able to automatic recognize halogenated gases
 
Power (No isolation transformer)
External AC power supply 
Input voltage100~240 V~/ 100~120V~
Input current3.5~8.5 A/8.5 A
Input frequency50/60 Hz
Leakage current< 500μA
Auxiliary output supply
Output voltage100~240 V~/ 100~120V~
Output frequency50/60 Hz