My-E003 Medical Device ICU Ventilator Movable Hospital Ventilator Machine

China My-E003 Medical Device ICU Ventilator Movable Hospital Ventilator Machine, Find details about China Movable Ventilator Machine, ICU Ventilator Machine from My-E003 Medical Device ICU Ventilator Movable Hospital Ventilator Machine

Model NO.
MY-E003
Pressure Range
1.0~6.0 Kpa
Inspiratory Platform
0~50%
Sigh
1.5 Times The Inspiratory Time
Trademark
MAYA
Transport Package
Wooden Box
Origin
Guangdong, China (Mainland)
Model NO.
MY-E003
Pressure Range
1.0~6.0 Kpa
Inspiratory Platform
0~50%
Sigh
1.5 Times The Inspiratory Time
Trademark
MAYA
Transport Package
Wooden Box
Origin
Guangdong, China (Mainland)
MY-E003 medical Movable hospital Ventilator Machine
My-E003 Medical Device ICU Ventilator Movable Hospital Ventilator Machine
Description of the ventilator:
1. Display mode:High-definition 8.4" TFT color LCD screen display
2. Ventilation  mode: IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
3. Ventilation parameters:
Tidal volume:50~1500 ml
Rate:2~99 bpm
SIMV rate:2~20 bpm
I:E:2:1~1:8
Inspiratory trigger pressure:-1.0~2.0kPa
PEEP:0~2.0 kPa
Pressure range:1.0~6.0 kPa
SIGH:1.5 times the inspiratory time
Inspiratory platform:0~50%
4. Parameters for ventilation monitoring     
tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform
5. Monitoring of oxygen concentration:21%~100%
6. Security Alarm System
Oxygen Concentration alarm     
upper limit setting range:50%~100%
low limit setting range:15%~50%
Airway pressure alarm               
upper limit setting range:1.0~6.0 kPa
low limit setting range:0.4~2.0 kPa
Per-minute ventilation volume alarm       
upper limit setting range:3.0~30L/min
low limit setting range:1.0~10L/min
Sustained high-pressure alarm      
it will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarm        
it will give sound and light alarm if there is no tidal volume input for 15  seconds
Power alarm
6. Power:AC 220V±10%     50Hz±1Hz
UPS, Storage battery
7. Mechanical Arms 
8. End-expiratory CO2 monitoring    (choose and match)

My-E003 Medical Device ICU Ventilator Movable Hospital Ventilator MachineMy-E003 Medical Device ICU Ventilator Movable Hospital Ventilator MachineMy-E003 Medical Device ICU Ventilator Movable Hospital Ventilator MachineMy-E003 Medical Device ICU Ventilator Movable Hospital Ventilator Machine