in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP

China in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP, Find details about China Pulse Oximeter, Pulse Oximeter Device from in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP

Model NO.
HP-810
Pr Measurement Range
30bpm-240bpm
Pr Accuracy
±1bpm or ±1%(The Larger One)
Operation Temperature
5°c-40°c
Storage Temperature
-10°c-40°c
Ambient Humidity
15%-80% on Operation,10%-80% in Storage
Air Pressure
70kpa-106kpa
Warranty
12 Months
Certificate
CE ISO
Trademark
healicom
Transport Package
Carton
Specification
CE ISO
Origin
Jiangsu, China
HS Code
9018199000
Model NO.
HP-810
Pr Measurement Range
30bpm-240bpm
Pr Accuracy
±1bpm or ±1%(The Larger One)
Operation Temperature
5°c-40°c
Storage Temperature
-10°c-40°c
Ambient Humidity
15%-80% on Operation,10%-80% in Storage
Air Pressure
70kpa-106kpa
Warranty
12 Months
Certificate
CE ISO
Trademark
healicom
Transport Package
Carton
Specification
CE ISO
Origin
Jiangsu, China
HS Code
9018199000
In stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP

in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP

Parameters:
Three Parameters: SPO2, Pulse Rate, NIBP
 
Waveforms:
SpO2 Waveform
 
Features:
COLOR OLED display, four direction adjustable.
SpO2 and pulse monitoring, and Waveform display.
Low-power consumption, continuously work for 50 hours.
Small in size, light in weight, and convenient to carry.
Low voltage alarm display, Auto power-off.
Runs on standard AAA batteries.
 
Detailed descriptions of product functions:

SPO2
Measurement range: 70%-99%
Accuracy: ±2% on the stage of 70%-99%, unspecified(<70%) for SPO2
Resolution: ±1%
Low perfusion: <0.4%

PR
Measurement: range:30BPM-240BPM
Accuracy: ±1BPM or ±1%(the larger one)
Power: two AAA 1.5V alkaline batteries
Power consumption: below 30mA
Automatic power-off: the product shuts down automatically after no signal for 8 seconds
Dimension: 62mm×32mm×33mm
Operation environment:
Operation temperature: 5°C-40°C,
Storage temperature: -10°C-40°C
Ambient humidity: 15%-80% on operation,
10%-80% in storage
Air pressure: 70kPa-106kPa

NIBP monitoring
Measurement method: Oscillometry
Measurement mode: manual/auto/continuous.
Auto measurement interval: adjustable from 1 to 255 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
Self-check function.
Overpressure protection: double protection for software and hardware.

Range: Adult
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg

Pediatric
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg

Neonate
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
Upper and lower limit of alarm
 
Configuration:

Standard Configuration
Options
SPO2 ETCO2
PR 
NIBPprinter
numerical valueUSB data upload
SpO2 waveform

Real Photos:
in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP
in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP

in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP

in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP

in Stock Medical Hospital Equipment Adult Child Neonate Baby Handheld Portable Pulse Oximeter with NIBP