Insulating Kraft Paper for Transformers/ Kraft Paper Manufacturer in China

Insulating Kraft Paper for Transformers/ Kraft Paper Manufacturer in China, Find details about China Insulation Materials, Insulation Paper from Insulating Kraft Paper for Transformers/ Kraft Paper Manufacturer in China

Classification
Inorganic Insulation Material
Certification
UL, ISO9001, IEC
Color
Brown
Trademark
Kang Liyuan
Transport Package
Pallet
Origin
China Mainland
Classification
Inorganic Insulation Material
Certification
UL, ISO9001, IEC
Color
Brown
Trademark
Kang Liyuan
Transport Package
Pallet
Origin
China Mainland
Features
This paper is highly refined and cleaned to ensure uniform thickness and free from formation Pinholes, un-dispersed fiber bundles and tiny defects
It is a low-voltage grade insulating paper well suited for making electromagnetic wires, power cables of
transformers below 35kV and other electrical insulating equipments below 35kV
This paper has stable electrical and chemical properties, and high physical strength to meet the exacting
needs of our valued customers



Insulating Kraft Paper for Transformers/ Kraft Paper Manufacturer in China



 
Applications

Used widely as electrical insulation wrap on aluminium and copper wires by conductor manufacturers,
electrical insulation between layers of wound coils in electrical motors, in capacitors, transformers & such
other electrical equipment.
 

Specifications
Our ordinary insulating papers are available in nominal thicknesses from 50 to 250 microns,
and in continuous rolls up to the widths of 625, 960mm and 1200mm (the roll diameter being 680 to 730mm),
or other customized diameters and widths on request.

 Test Report
Product Name: Cable Paper
Test Method used: KLYQB-2005
Manufacture: Kang Liyuan Science & Technology (Tianjin) Co.,Ltd.
Date: January, 2019
 
Test No.ItemUnitQualified DataTest Data
1Tightnessg/cm30.90±0.050.92
2Tensile strengthverticalKN/m11.011.3
horizontal5.25.28
3
 
Elongationvertical%22.1
horizontal≥5.45.5
4Tear Strength(horizontal)MN10201212
5Conductivity of Water ExtractMS/m8.04.2
6Breakdown VoltageKV/ mm8.08
7Dissipation Factor---≤0.50.38
8PH of Water Extract---6.5~8.57.5
9Ash Content%≤0.70.26
10Moisture Content%6.0~8.07.5
Conclusion and Result:

PASS



                           Kang Liyuan Science & Technology (Tianjin) Co.,Ltd.
                                                 Technology Center
Tested by:  Shuli Wang                 Inspected by:  Tianfeng Yang


Please Contact Us
Miss: lea
 

https://kangliyuan.en.made-in-china.com