China Xg Wholesale Factory Price High Frequency Online UPS Power Frequency UPS 3kVA, Find details about China Online UPS, UPS from Xg Wholesale Factory Price High Frequency Online UPS Power Frequency UPS 3kVA
Item | Model | XG1K/1KL | XG2K/2KL | XG3K/3KL |
Capacity | VA / Watts | 1KVA / 0.8KW or 0.9KW | 2KVA / 1.6KW or 1.8KW | 3KVA / 2.4KW or 2.7KW |
input | Normal voltage | 220VAC or 110VAC | ||
Turn on Voltage range | (115+-5~300+-5)VAC or ( 60+-5-138+-5)VAC | |||
Frequency range | 40~60Hz(adjustable) | 40~60Hz(adjustable) | 40~60Hz(adjustable) | |
Input power factor | >0.99(220VAC,full R load) | |||
Generator | Support generator input(Generator rating≥2*UPS rating ) | |||
line low loss/comeback | 220VAC:(110±5)VAC/(195±5)VAC when Load≤55%, 110VAC:(60±3)VAC/(65±3)VAC when load≤40% | |||
220VAC:(130±5)VAC/(195±5)VAC when56%< Load≤65%, 110VAC:(60±3)VAC/(75±3)VAC when40%< load≤50% | ||||
220VAC:(150±5)VAC/(195±5)VAC when66%< Load≤70%, 110VAC:(70±3)VAC/(75±3)VAC when50%< load≤60% | ||||
220VAC:(160±5)VAC/(195±5)VAC when71%< Load≤90%, 110VAC:(70±3)VAC/(85±3)VAC when60%< load≤70% | ||||
220VAC:(185±5)VAC/(195±5)VAC when Load>90%, 110VAC:(90±3)VAC/(95±3)VAC when load>70% | ||||
Output | Voltage range | 200VAC/208VAC/220VAC/230VAC/240VAC/110VAC/120VAC, need confirm before order | ||
Frequency range | 50Hz or 60HZ+-0.2Hz(Battery mode) | |||
Wave form | Pure Sine Wave | |||
Transfer time | 0 ms, Between Line mode and Bat mode | |||
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode | ||||
Distortion | ≤4%,Full linear load | ≤4%,Full linear load | ≤4%,Full linear load | |
Degree of distortion | ≤7%,Full nonlinear load | ≤7%,Full nonlinear load | ≤7%,Full nonlinear load | |
Overload capacity | <105% warning only, <125% 30s ; <150% 20s,>150%, 300MS to bypass | |||
Load peak ratio | 3:1(max) | |||
Standard Modes XG1-3K | Battery Type | Maintenance free valve regulated lead acid (VRLA) battery | ||
Battery voltage | 24VDC or 36VDC | 48VDC or 72VDC | 72VDC or 96VDC | |
Internal Battery | 2*7AH(9AH) or 3*7AH | 4*7AH(9AH) or 6*7AH or 8*7AH | 6*7AH(9AH) or 8*7AH | |
Recharge time | 5 hours to 90%capacity | |||
Charge Current | 1A | 1A | 1A | |
Long backup ModeXG1-3KL | Battery bank | 36VDC, External | 72VDC,External | 96VDC,External |
Charge Current | 5Amp,Max 7Amp | 5Amp,Max 7Amp | 5Amp,Max 7Amp | |
Display | LED Mode | Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault | ||
LCD Mode | input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss | |||
Audible Alarm | Battery Mode | Beeping every 4 seconds (re-settable) and every second when battery low | ||
Overload | Beeping twice every second | |||
Fault | Beeping Continuously | |||
Bettery low/charger fault | Beeping every 1 second | |||
Bypass mode | Beeping every 2 min | |||
L/N inverse | Beeping every 2 min | |||
Communications | RS-232/USB Interface | With monitoring software | ||
Working Environment | Surge protection | RJ-45 I/O port available for network or Fax/Modem | ||
Working temperature | - 20ºC~40ºC | |||
Humidity | 0-95% non-condensing | |||
Product size | WxDxH (mm) | 350*145*230(H) | 430*190*328(H) | 430*190*328(H) |
PCS/CTN | 2 | 1 | 1 | |
CTN size | WxDxH (mm) | 495*470*340(H) | 570*305*450 (H) | 570*305*450 (H) |
N/W, CTN XG1-3K | Kg | 19/23 (base on 7AH) | 19/23/28 (base on 7AH) | 24/28 (base on 7AH) |
N/W, CTN XG1-3KL | 12 | 12 | 12 | |
G/W, CTN XG1-3K | Kg | 21/25 | 21/25/30 | 25/30 |
G/W, CTN XG1-3KL | 15 | 14 | 14 | |
REMARK | XG*K --- Standard Type Internal battery, XG*KL Long Time Type,External battery |