Eberry Vs1-12 P=275 12kv High Voltage Indoor Vacuum Circuit Breaker Vcb Electric Type Manual Type 2500A

China Eberry Vs1-12 P=275 12kv High Voltage Indoor Vacuum Circuit Breaker Vcb Electric Type Manual Type 2500A, Find details about China Vcb, Vacuum Circuit Breaker from Eberry Vs1-12 P=275 12kv High Voltage Indoor Vacuum Circuit Breaker Vcb Electric Type Manual Type 2500A

Model NO.
ZN63 VS1-12
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CQC
Rated Voltage
12kv
Rated Frequency
50/60Hz
Rated Current
1600A-3150A
Phase Distance
275mm
Trademark
Eberry
Transport Package
Plywood Box
Origin
Yueqing, Zhejiang
Model NO.
ZN63 VS1-12
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CQC
Rated Voltage
12kv
Rated Frequency
50/60Hz
Rated Current
1600A-3150A
Phase Distance
275mm
Trademark
Eberry
Transport Package
Plywood Box
Origin
Yueqing, Zhejiang
    
Eberry Vs1-12 P=275 12kv High Voltage Indoor Vacuum Circuit Breaker Vcb Electric Type Manual Type 2500A
Eberry Vs1-12 P=275 12kv High Voltage Indoor Vacuum Circuit Breaker Vcb Electric Type Manual Type 2500A
Eberry Vs1-12 P=275 12kv High Voltage Indoor Vacuum Circuit Breaker Vcb Electric Type Manual Type 2500A
Eberry Vs1-12 P=275 12kv High Voltage Indoor Vacuum Circuit Breaker Vcb Electric Type Manual Type 2500A
Description:

VCB-12 series solid-sealed indoor vacuum circuit breaker is an indoor high-voltage switchgear for three-phase power system with rated voltage of 12 kV and frequency of 50 Hz. It is used as protection and control appliance due to vacuum circuit breaker. The special advantages are especially suitable for frequent operations requiring rated current or multiple short-circuit currents.
 
VCB-12 series solid-sealed indoor vacuum circuit breakers are fixedly mounted, mainly used for fixed switchgear. The circuit breaker can be used alone or in ring power supply, box transformer or various non- power supply system.

Technical parameters:

1.Rated voltage KV 12
2.Rated short-duration power frequency withstand voltage KV 42/48(Interphase, ground/fracture)
3.Rated lightning impulse withstand voltage KV 42/48(Interphase, ground/fracture)
4.Rated frequency Hz 50
5.Rated current A 630 1250 630 1250 1600 2000 2500 3150 630 1250 1600 2000 2500 3150
6.Rated short-circuit breaking current KA 20/25,31.5,40
7.Rated short-time withstand current KA 20/25,31.5,40
8.Rated short circuit duration S 4
9.Rated peak withstand current KA 50/63,80,100
10.Rated short circuit closing current KA 50/63,80,100
11.Secondary circuit power frequency withstand voltage (1min) V 2000
12.Rated single / back to back capacitor group breaking current A 630/400(40kA:800/400)
13.Rated capacitor bank closing current: 12.5 (frequency is not greater than 1000Hz)
14.Mechanical life times 20000
15.Rated current breaking times (electrical life) times 20000
16.Rated short circuit current breaking times times 50(40KA≤30)
17.Dynamic and static contacts allow wear cumulative thickness mm 3
18.Energy storage time s ≤10
19.Contact opening distance mm 11±1
20.Overtravel mm 3.5±0.5
21.Contact closing bounce time ms ≤2(40KA≤3)
22.Three-phase split/closed period ms ≤2
23.Average opening speed (contacts are separated by -8mm) m/s 1.2±0.2
24.Average closing speed(8mm-contact closure) m/s 0.6±0.2
25.Main conductive loop resistance μΩ ≤50(630A)≤45(1250A) ≤40 (1600,2000A)≤35 (2500A or more)
26.Rated operation sequence: 0-0.3s-Co-180s-Co