Function features:

Microprocessor based servo controlled temperature system
The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic
APGAR timer to record therapy time
Audible and visual Alarm functions :
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
Heater head can be adjusted ±90° horizontally
Convenient X-ray cassette tray under infant bed
Tilt angle of infant bed is adjustable
LED observation light adjustable, brightness adjustable
A second thermal cut-out function for more safety
Four Transparent protector folded with 2 infusion seals
Skin temperature sensor failure protect function avoid over temperature
RS-232 connector, 1 tray


Top Grade Hospital Use Baby Care Equipment Infant Radiant Warmer Technical Data:
Power supply AC110/220V 60/50Hz
Power input9 00VA
Operating conditionEnvironment temperature18°C ~ 30°C
Environment relative humidity30% ~ 75%
Atmospheric Pressure 700~1060hpa
Environment air velocity of flow< 0.3m/s
Skin temperature control range32°C ~ 38°C
Skin temperature control accuracy≤0.5°C
Skin temperature sensor accuracy±0.3°C
Mattress temperature uniformity< 2°C
Infant Bed tilt angle±1
Warm-up time(from 25°C)< 30min
Heater head horizontal ±90°
Distance from heater to mattress 80cm
Mattress size67cm X 54cm
Timer range0 ~ 99h59min

Top Grade Hospital Use Baby Care Equipment Infant Radiant Warmer Transport and storage:
Package: Each unit is packed one plywood case
Size:110* 78*86cm
N.W.:65Kg G.W.:85Kg
Transport and storage:
Environment temperature: -40°C ~ + 55°C
Environment relative humidity: ≤95%
Atmospheric Pressure: 500 ~ 1060hpa


Standard configuration:
Main body (including the Radiant source, Control system, Infant bed, Bracket), I.V.pole, Skin temperature sensor, Tray, Mattress, Transparent protector, Castors, RS-232

Excellent detail:

Heating head with metal grid
Siderail colume
Aluminium alloy material
2 infusion seals

Top Grade Hospital Use Baby Care Equipment Infant Radiant Warmer Picture:
Top Grade Hospital Use Baby Care Equipment Infant Radiant Warmer