China 110W, 54V 1.6A, 3.4V 7A Power Supply, Find details about China 110W, 54V 1.6A from 110W, 54V 1.6A, 3.4V 7A Power Supply
Item | Unit | Min | Typ. | Max | Remark |
Nominal operation temperature | ºC | -5 | 25 | 55 | Safety approved. |
Operation temperature | ºC | -25 | 25 | 65 | The power system normally operates. |
Relative humidity | % | 5 | 93 | No condensing | |
Absolute humidity | g/m3 | 0.26 | 25 | No condensing | |
Altitude | m | - | - | - | Operation atmospheric pressure: 70kPa~106kPa |
Cooling | Natural cooling. The heat generated by customized power shall be conducted to the enclosure through contact with max temperature of 65ºC and the conduction section shall be 28555mm2. | ||||
Operating duration | 24Hs continuous work. |
Item | Unit | Min | Typ. | Max | Remark |
Storage temperature | ºC | -40 | - | 80 | |
Relative humidity | % | 0 | - | 95 | |
Absolute humidity | g/m3 | 0.03 | 30 | ||
Altitude | m | 0 | 2000 | ||
Temperation variation | ºC/min | 1 |
Item | Unit | Min | Typical | Max. | Remark |
Rated input voltage | Vac | 220 | |||
Input voltage range | Vac | 85 | 220 | 290 | Nominal input voltage: 100-240Vac |
Input frequency | Hz | 43 | 50 | 67 | |
Inrush current | A | 30 | 25ºC cold startup 290V input, full load | ||
Input power factor | 0.95 | Rated full load |
Output voltage | Output voltage rating | Output current | Load Regulation | Line regulation | Regulation | Vp-p |
-54V | -53.5~-54.5V | 1.6A | ≤±2% | ≤±2% | ≤±3% | ≤±3% |
3.4V | 3.3~3.5V | 7A | ≤±2% | ≤±2% | ≤±3% | ≤±3% |
Item | Unit | Min | Typical | Max. | Testing Conditions |
Output power | W | - | 110.2 | ||
110V Output efficiency | % | 80 | Test with load of 2.5A at -54V and 8A at 3.4V. The ambient temperature is 25ºC.There shall be no battery and backup power during the test. | ||
220V Output efficiency | % | 82 | |||
Temperature coefficient | /ºC | 0.03% | |||
Over/under shoot @start up/shutdown | 5% | ||||
Transient response overshoot | 5% | Di/dt=10A/s, 25%~50%~75%Load variation with rate ≤0.1A/uS, calculated from the part out of the output line regulation range. | |||
Transient response recovery duration | μS | 200 | |||
Turn on time | S | 4 | Rated input/output | ||
Output voltage boost duration | mS | 100 | Rated input/output, boost from 10% to 90% | ||
Capacitive load capability | uF | 1000 | -54V | ||
uF | 4000 | 3.4V | |||
3.4V power down delay | mS | 10 | The input voltage keeps to 3.4V/8A. There shall be no battery and backup power during the test. |
Item | Requirement | Remark |
Float voltage | 54V | Regulation: ±2% |
Current limiting for equalizing/float charge | Equalize charge with voltage not more than -56V and then float charge. | ≤1A |
U/V alarm set point | 46±1V | Alarm through potential free contact |
Power down protection set point | 43.5±0.5V | |
Leakage current | Not supplied | <0.35mA |
Recovery set point | From battery shutdown till the re-power on of rectifier AC input | |
Temp. compensation coefficient | Not supplied | Not supplied |
Battery capacity | 7AH | Default configuration (with charge capacity of 10-12AH) |
Battery reversed polarity protection | Supplied | |
Battery current limiting | Current limiting circuit is supplied for battery discharge | The fuse will be blown at over current. |
Item | Unit | Min | Typical | Max. | Recovery Property |
Input O/V protection set point | V | 290 | 310 | 320 | Without battery and backup power |
Input O/V recovery set point | V | 290 | 300 | 320 | |
Input O/V protection hysteresis | V | 8 | |||
Input U/V protection set point | V | 60 | 65 | 85 | Without battery and backup power |
Input U/V recovery set point | V | 60 | 75 | 85 | |
Input U/V protection hysteresis | V | 8 | |||
-54V output O/V protection | V | -59 | -62 | -65 | Lock up, without battery and backup power |
3.4V output O/V protection | V | 3.7 | 3.95 | 4.2 | |
-54V output over-current protection | A | 2.75 | 3 | 3.75 | Auto-recoverable, without battery and backup power, 3.4V, with 8A full load |
3.4V output over-current protection | A | 11 | 13 | 15 | Auto-recoverable, without battery and backup power |
Thermal protection | ºC | Auto-recoverable, without battery and backup power | |||
Short circuit protection | A | Damage free under long-term short circuit, auto-recoverable, without battery and backup power | |||
Input power failure alarm | Auto-recoverable, without battery and backup power | ||||
Output protection requirement | Output protection at 3.3V shall not affect the output at -54V. |
Item | Rating | Standard(or Testing condition) |
Insulation voltage(output-GND) | 500Vac | 500Vac/1Min / Leakage current≤10mA, no breakdown or flashover |
Insulation voltage (input -GND) | 1500Vac | 1500Vac/1Min / Leakage current≤10mA, no breakdown or flashover |
Insulation voltage (input to output) | 3000Vac | 3000Vac/1Min / Leakage current≤10mA, no breakdown or flashover |
Insulation resistance | 10MΩ | RH:<90%, DC 500V, the insulation resistance of input to output, input to ground, and output to ground is not less than 10MΩ. |
Leakage current | <3.5mA | Max input operation voltage, 50Hz input |
Item | Requirement | Standard |
CE | CLASS B for integrated and CLASS A for single equipment | EN55022 |
RE | CLASS B for integrated and CLASS A for single equipment | EN55022 |
Harmonic current | CLASS D | IEC 61000-3-2[6] |
CS | Testing frequency: 0.15MHZ-80MHZ; Electric strength: 3V; AM: 80% (1KHZ) | IEC61000-4-3 (Criterion A) |
RS | Testing frequency: 80MHZ-1000MHZ; Electric strength: 10V; AM: 80% (1KHZ) | IEC 61000-4-6 (Criterion A) |
ESD | Air discharge: ±8KV | IEC 61000-4-2 (Criterion A) |
Contact discharge: ±6KV | ||
Voltage ripple & flicker | PST≤1.0;PLT≤0.65;dC≤3%;dmax≤4%;Vd(t) is 3% or less when the voltage ripple duration is more than 200ms | IEC61000-3-3 |
EFT/B | ±2KV | IEC61000-4-4 (Criterion B) |
SURGE | Basic: Wire-wire: 2Ω IR, ±1KV Wire-GND: 12Ω IR,±2KV (Criterion B) Strengthening: Wire-wire: ±4KV, 2Ω IR, Wire-GND: ±6KV, 12Ω IR, (Criterion R) | EN61000-4-5 |
DIP | The voltage derates to 70%Ut and the duration is 100ms (5 periods), conforms to criterion B at 0°,45°,90°,135°,180°,225°, 270°, 315°. | EN61000-4-11 Ut=264Vac:Criterion A Ut=220Vac:Criterion A Ut=90Vac:Criterion A |
The voltage derates to 70%Ut and the duration is 20ms(1 period),conforms to criterion B at 0°,45°,90°,135°,180°,225°, 270°,315°. | EN61000-4-11(Criterion B) | |
The voltage derates to 0%Ut and the duration is 10ms(Half a period) | EN61000-4-11(Criterion B) | |
Others | EN61000-4-11(Criterion B) |
Item | Requirements | Property |
Acoustic noise | <50dB(A) | Pass |
MTBF | ≥80,000H | |
Annual repair rate | ≤0.2% | |
Operation vibration | 5-9Hz,3.5mm;9-200Hz: 1g; 3 axes, SF for 5 times per axis | Pass |
Random vibration | Acceleration spectral density, 5~20Hz: 1.0;20~200Hz: -3dB; RMS acceleration: 0.781Grms 3 axes Testing duration: 30min per axis | Pass |
Impact | Impact waveform: Half-sine wave; Acceleration Vp: 300m/s2 Pulse width: 6ms; 6 axes 3 times per axis | Pass |
Bump | Bump waveform: Half-sine wave; Acceleration Vp: 180m/s2 Pulse width: 6ms; 6 axes 100 times per axis | |
Drop | Weight: ≤15kg Height: 100cm Drop test for 1 angle, 3 prisms and 6 surfaces: Angle: Choose the frailest one for test, if unavailable, the angel 2-3-5 shall be applied. 3 pcs of prisms: prism that joint at the base angle 6 pcs of faces: surfaces of tested unit Drop time: once per surface | |
Damp proof | 24~45ºC,95%RH,48h | GB/T 2423.4-1993 |
Mildew proof | Mildew test Class B | GB/T 2423.16-1999 |
Smog proof | Smog test, 96H | GB/T 2423.17-1999 |
Dustproof | Dust with diameter more than 5um shall be not more than 3×104 particles/m3,the dust particles shall be non-conducting and non-corrosive. | Pass |
Static pressure | TL=Wt×(S-1)×F×9.8(N) TL: pressure applied, unit: N; Wt: weight of packaged piece, unit: kg; S: stack available, adopt the maximum value; F: safety coefficient, usually specified as 5; S=3/h; h--height of packaged piece, unit: m The pressure shall be imposed for 2H. | |
Low voltage | Tested at 4000m altitude | Refer to GB2423 |