Bsc -1000iia2 Class II Biological Safety Cabinet

China Bsc-1000iia2 Class II Biological Safety Cabinet, Find details about China Biological Safety Cabinet, Hospital Equipment from Bsc-1000iia2 Class II Biological Safety Cabinet

Model NO.
BSC-1000IIA2
Model
Bsc-1000iia2
Application
Medical
Class
Class 100
Suit
One Person
Certication
ISO 9001
Overall Dimension(L*W*H)
1200*750*1950mm
Working Area
1000*650*580mm
Weight
150kg
Power Supply
AC, 220V
Trademark
SUGOLD
Transport Package
Wooden
Specification
GMP
Origin
Zhejiang, China
HS Code
9031200090
Model NO.
BSC-1000IIA2
Model
Bsc-1000iia2
Application
Medical
Class
Class 100
Suit
One Person
Certication
ISO 9001
Overall Dimension(L*W*H)
1200*750*1950mm
Working Area
1000*650*580mm
Weight
150kg
Power Supply
AC, 220V
Trademark
SUGOLD
Transport Package
Wooden
Specification
GMP
Origin
Zhejiang, China
HS Code
9031200090
BSC-1000IIA2 Class II Biological Safety Cabinet
Clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as medicine, pharmacy, scientific research and so on. Main characters
1 It accords with physical engineering principle, 10° Inclination design, so the operating feel is more excellent.
2 Air insulation design to avoid cross pollution inside and outside air circulation. 70% Air Recirculation, 30% Air Exhaust, vertical laminar negative pressure.
3 Equipped with spring up/down movable door in the front and back of work bench, flexible and convenient to locate
4 Equipped with special filter on ventilation to keep vented air conforming to national standard.
5 Contact switch adjusts voltage to keep wind speed in working area in ideal state all the time.
6 Operate with LED panel.
7 The material of the work area is 304 stainless steel.
Parameter / model BSC-1000IIA2 BSC-1300IIA2 BSC-1600IIA2
Cleaning level 100 Level(USA Federal Standard 209E)≥ 0.5um Granulae≤ 3.5per liter
Descending wind speed ≥ 0.35m/s
Wind speed in ≥ 0.55m/s
Noise ≤ 58dB(A)
Half ventilation peak value ≤ 3µ M
Power supply/Max. Power consumption AC220V/50Hz/1KW


Biological safety Personnel protection: Impact type sampler: CFU≤ 10,
Product protection: All sampling vessels: CFU≤ 5
Cross contamination protection: All double dishes: CFU≤ 2
Working area 1000*650*580 1300*650*580 1600*650*580
Overall dimension 1200*750*1950 1500*750*1950 1800*750*1950
Specification of air-supply filter 955*545*50*1 1290*554*50*1 1590*554*50*1
Specification and number of fluorescent lamp or UV lamp 20W*2/20W*1 30W*2/30W*1 30W*2/30W*2
Illumination ≥ 650LX ≥ 650LX ≥ 650LX
Weight(kg) 300 340 380
Suit Single Double Double
Parameter / modelBSC-1000IIA2BSC-1300IIA2BSC-1600IIA2
Cleaning level100 Level(USA Federal Standard 209E)≥0.5um Granulae≤3.5per liter
Descending wind speed≥0.35m/s
Wind speed in≥0.55m/s
Noise≤58dB(A)
Half ventilation peak value≤3µm
Power supply/Max. power consumptionAC220V/50HZ/1KW
 
 
Biological safety
Personnel protection: impact type sampler: CFU≤10,
Product protection: all sampling vessels: CFU≤5
Cross contamination protection: all double dishes: CFU≤2
working area1000*650*5801300*650*5801600*650*580
Overall dimension1200*750*19501500*750*19501800*750*1950
Specification of air-supply filter955*545*50*11290*554*50*11590*554*50*1
Specification and number of fluorescent lamp or UV lamp20W*2/20W*130W*2/30W*130W*2/30W*2
Illumination≥650LX≥650LX≥650LX
Weight(kg)300340380
SuitSingleDoubleDouble

Bsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety CabinetBsc-1000iia2 Class II Biological Safety Cabinet