Tower UPS - 220V Tower Online UPS Power Supply
1: Tower UPS with 220/230/240V Input/Output
2: UPS Frequency 50/60Hz auto detect
3: Ture Online Double Conversion UPS Technology
4: Pure Sine Wave Output Online UPS Model
5: Large LCD Display for UPS Status
Tower UPS - 220V Tower Online UPS Power Supply Key Features:
1: True on-line double conversion technology with advanced microprocessor control
2: Wide input voltage range
3: Zero transfer time
4: Protection against all type of power problems, Like: Power sags, high voltage spikes, switching transients, power surges, noise, frequency variation, brownout. Overload, Short Circuit, Overcurrent, Unbalanced Loads, Overvoltage
5: Self test while start of the UPS
6: Site wiring fault warning
7: On-battery power-on function
8: Smart RS232 and USB communication interface
9: Intelligent SNMP Card slot available
10: Built-in Sealed lead acid, maintenance free battery
11: Pure sine wave output
12: Single Phase In/Out for UPS 1-10KVA, Three Phase In and Single Phase out for UPS10-20KVA
13: Large LCD Display Large blue back light LCD for detailed real-time UPS status display
14: Microprocessor control guarantees high reliability
15: Comprehensive self-protection design
16: Audible alarm mute
17: Cold start function
18: Auto self-testing system while turning on UPS
19: Maintenance bypass switch for 6k to 20K
20: N + X parallel redundancy and capacity expansion for 6k to 20K
21: MCU (Freescale) +IGBT+DSP (TI) technology and double conversion structure.
UPS Model | EX1K | EX1KL | EX2K | EX2KL | EX3K | EX3KL |
Capacity | 1000VA/800W | 2000VA/1600W | 3000VA/2100W |
Input | Voltage | (115~300)VAC |
Frequency | 46~54Hz/56~64Hz (Adjustable via LCD panel) |
Output | Voltage | 220/230/240 (1±1%) VAC (Adjustable via LCD panel) |
Frequency | 50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz): Battery Mode: 50Hz1±0.2%) 60Hz AC Mode: Follow AC Mode (AC Range56~64Hz): Battery Mode: 60Hz (1±0.2%) |
Output Wave Form | Pure Sine Wave |
Back-up Time | Full Load | ≥5′ | Depends on the capacity of the external battery bank | ≥9′ | Depends on the capacity of the external battery bank | ≥5′ | Depends on the capacity of the external battery bank |
Half Load | ≥14′ | ≥21′ | ≥15′ |
BatteryNominal DC Voltage | 36VDC | 96VDC |
Transfer Time | 0ms |
Overload Capacity | 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms |
Communications | RS-232+Intelligent Slot |
Environment | Temperature | 0~40 Centigrade |
Humidity | 15%~90% |
Dimensions (W*D*H) mm | 145*400*220 | 192*460*340 |
Net Weight (Kg) | 14 | 7 | 34 | 13.5 | 34.5 | 14 |
Any more requirements about us,pls feel free to contact Bella