3D Iron Core Transformer Three Phase - Scb Series

China 3D Iron Core Transformer Three Phase

Model NO.
SCB
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Brand
Nce
Vector-Group
Dyn11 / Yyn0
Trademark
NCE
Transport Package
Export Standard Package
Specification
10KV
Origin
Jiangsu, China
HS Code
8504210000
Model NO.
SCB
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Brand
Nce
Vector-Group
Dyn11 / Yyn0
Trademark
NCE
Transport Package
Export Standard Package
Specification
10KV
Origin
Jiangsu, China
HS Code
8504210000
3D Iron Core Transformer Three Phase - SCB Series

Model Description
3D Iron Core Transformer Three Phase - Scb Series
3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series3D Iron Core Transformer Three Phase - Scb Series
Product Use

The product has the following features: good insulation properties, high mechanical strength, moisture resistant, pollution-free, easy to install, and almost no need for maintenance. Can be applied for high rise buildings, wind power generation, solar energy, hospital, hotel, tunnel, station, wharf, airport, subway, petroleum, chemical industry, laboratory, combined power plant, shopping mall and other important places etc.

Product Usage Condition

(1).Altitude
Not more than 1000m;
(2).Cooling air temperature
Max. Temp.: 40ºC
Max. monthly mean temp.: 30ºC
Max. annual mean temp.: 20ºC
lowest temp.: -25ºC( suitable for outdoor transformer )
lowest temp.: -5ºC ( suitable for indoor transformer )
(3).Humidity
Ambient air relative humidity should be less than 93%, no water drop on the coil surface. If usage condition exceeds above requirements, should adjust running parameters (e.g. output current etc.) properly and adopt proper protecting measures to ensure the product service life and safety reliability.


Performance Parameter Table
 
Product Type Rated Capacity
(KVA)
Voltage CombinedVector- groupNo-load Loss (w)load Loss (w)
120ºC
No-load
current (%)
Short- circuit
impedance (%)
Noise
(dB)
HV(KV)Tapping RangesLV(KV)
SC10-30/10306
6.3
6.6
10
10.5
11
±5%
±2×2.5%
0.4Dyn11
or
Yyn0
1907100.94.050
SC10-50/105027010000.950
SC10-80/108037013800.950
SC10-100/1010040015700.650
SC10-125/1012547018500.650
SCB10-160/1016054021300.650
SCB10-200/1020062025300.550
SCB10-250/1025072027600.550
SCB10-315/1031588034700.550
SCB10-400/1040098039900.450
SCB10-500/10500116048800.450
SCB10-530/10530134058800.355
SCB10-600/10630130059600.36.055
SCB10-800/10800152069600.355
SCB10-1000/101000177081300.355
SCB10-1250/101250209096900.2555
SCB10-1600/1016002450117300.2555
SCB10-2000/1020003050144500.255
SCB10-2500/1025003600171700.255

FAQ
 
Q: What certificates and standard does your company have?
A: Our factory has ISO9001:2008, ISO14001:2004, OHSAS18001:2007 certificates.
We can send products to appointed laboratories for testing if necessary.
Q: How long is your delivery time?
A:For 10KV distribution transformer, the production cycle of our factory is 20~25 days.
Q: What is your service?
A: we have quick response in before sales period help you got order, and excellent service in production time let you know each step we made.
Q: What is the guarantee?
A: Generall 1-2 years, when the guarantee period ends up, we are responsible for life-long maintenance and would charge some fees concerning costs.
Q: What is the standard of package? 
A: Export standard package or special package according to customer requirement
Q:What is your payment term?
A:All terms of payment is acceptable.