Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing

China Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing, Find details about China CT PT Test Kit, Current Transformer Testing Equipment from Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing

Model NO.
GDVA-405
Current Output
0.001~5A(RMS)
Power Output
500va
Product Name
CT PT Tester
Trademark
GOLD
Transport Package
Standard Wooden Case
Specification
30KG
Origin
Chongqing, China
HS Code
9030849000
Model NO.
GDVA-405
Current Output
0.001~5A(RMS)
Power Output
500va
Product Name
CT PT Tester
Trademark
GOLD
Transport Package
Standard Wooden Case
Specification
30KG
Origin
Chongqing, China
HS Code
9030849000
Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45KV Knee Voltage Testing

Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage TestingCurrent and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing
GDVA-405 Automatic CT PT Analyzer is designed as per IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, IEC61869,C57.13.  it is applied to test the CT and PT (220V~500KV,>2.5VA) and which turns ratio value is more than 1:1. the accuracy is 0.02%.  and the operation is very simple, you can only connect the cables according the circuit diagram as shown on panel, and set up the main parameters according to your CT and PT, then click"RUN", It can complete all the test items for CT PT in one test. you can also test them separately. GDVA-405 is the top in China. it sold very well in India, Pakistan,Malaysia,Mexico and so on.
Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing
Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage TestingCurrent and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing

Application:

Tests for current transformer:

  • Excitation curve and parameters test

  • Turns ratio test

  • Ratio and phase error test

  • Polarity mark check

  • Winding resistance measurement

  • Secondary loop burden measurement

  • Error line curve test for protection CT

  • Transient CT parameters test

  • CT nameplate guess

  • Saturation hysteresis loop curve measurement

  • Tests for Potencial Transformer:

  • Turns ratio test

  • Ratio error and phase angle error test

  • Polarity test

  • Secondary burden test

  • Winding resistance test

Applications of CT/ PT Analyzer:

  • CT nameplate check

  • CT parameters check in work burden

  • CT transient parameters analysis

  • CT ratio and phase error calibration

  • PT routine test

 

Specifications:

Item NameGDVA-405 CE Certificate Automatic Current Transformer CT and PT Potentional Transformer Tester
Test standardsIEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply AC220V±10%, 50/60Hz±10%
Voltage output 0.1~180V (AC)
Current output 0.001~5A(RMS)
Power output 500VA
Max.  knee voltage measurement 45KV
Current measurement
 

 
  Range0~10A (automatically change  range in 0.1/0.4/2/10A)
  Error <±0.1%+0.01%FS

 

Voltage measurement
 
 Range0~200V (automatically change range in 1V/10V/70V/200V)
 Error< ±0.1%+0.01%FS
Turns ratio measurement Range
  
1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement  error ±2min
resolution 0.01min
Winding resistance measurement
    
   
Range0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
Temperature measurement-50~100 Celsius degree; error<3 Celsius degree
CT Secondary burdenRange0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
   
  
PT Secondary burden

 
Range0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error<0.2%RDG+0.02%FS
Maximum resolution : 0.1ohm
   
PT ratio measurement
Range

1~35000,

1~10000 error<0.1%, 

10000~35000 error<0.2%

PT ratio error measurement :Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity >1000 groups test results
Working condition temperature -10ºC~50ºC; moist ≤90%

Rating and Review:
Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing
Our Company:
Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing
Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd is founded in 2008. We have a strong team including top sales, skilled engineers and we have our own manufacture with high quality. we mainly design and manufacture the Transformer Tester,  Circuit Breaker Analyzer,  CT PT Analyzer, Hipot Tester ,  Relay Tester and so on for more than 10 years.

After several years' development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;

We have developed sales channels in many countries such as UAE, Saudi Arabia, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.
And we have gained strong advantage and high reputation in international market.


Certificates:
Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing
Exhibition:
Current and Voltage Transformer Testing Equipment, CT PT Test Kit with 45kv Knee Voltage Testing