Double Channel Syringe Pump with Drug Library

China Double Channel Syringe Pump with Drug Library, Find details about China Infusion Pump, Medical Equipment from Double Channel Syringe Pump with Drug Library

Model NO.
SLV-810
Infusion Rate
Ml/H Mode: 1-1200ml/H (1ml/H Step)
Purge Rate
100ml/H---1200ml/H (Can Be Calibrated)
Flow Rate Accuracy
Ml/H Mode: Within 5% (After Correct Calibration)
Mechanical Precision
Within 2%
Maximum Infusion Pressure
150kpa
Kvo Speed
1ml/H---5ml/H (1ml/H Step)
Volume Limit
1ml---9999ml
Total Infusion Volume
0---9999.9ml
Needle
Optional
Group
Adult
Rate Accuracy
Within 3%
Mechanical Accuracy
Within 2%
Voice Alam System
Yes
Trademark
Shileva
Transport Package
Carton
Origin
China
HS Code
9018390000
Model NO.
SLV-810
Infusion Rate
Ml/H Mode: 1-1200ml/H (1ml/H Step)
Purge Rate
100ml/H---1200ml/H (Can Be Calibrated)
Flow Rate Accuracy
Ml/H Mode: Within 5% (After Correct Calibration)
Mechanical Precision
Within 2%
Maximum Infusion Pressure
150kpa
Kvo Speed
1ml/H---5ml/H (1ml/H Step)
Volume Limit
1ml---9999ml
Total Infusion Volume
0---9999.9ml
Needle
Optional
Group
Adult
Rate Accuracy
Within 3%
Mechanical Accuracy
Within 2%
Voice Alam System
Yes
Trademark
Shileva
Transport Package
Carton
Origin
China
HS Code
9018390000
Product Information:Double channel syringe pump with drug library

Features of Dual Channel Syringe Pump 

1. HD LCD Display, high capacity words, friendly user interface, dynamically display working status;

2. Visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting, etc.;

3.The syringe pump can be operated separately and compatible with 5ml, 10ml, 20ml, 30ml, 50/60ml syringe of any brands;

4. Preset solution volume to greatly reduce the workload of nurses;

5. Three working modes: Rate Amode, Time Volume mode, Dosage Weight mode;

6. Three levels of occlusion: high, medium and low;

7. Purge and Bolus function;

8. KVO (keep-vein-open) automatically opens as injection is completed, KVO rate is 1ml/h;

9. Power Source: AC100---240V, 50/60Hz; Internal Battery, DC12V car charge;

10. One-key operation makes setup easy and simple;

11. Syringe plunger grabble detector, operable with one hand in a No-Germ Environment;

12. Automatically record the settings of last injection;

13. OEM is available.
 
Specification of Dual Channel Syringe Pump 
 
Rate 50/60ml Syringe: 0.1ml/h ~ 999.9ml/h (0.1ml/h step) 
1,000ml/h ~ 1,500ml/h (1ml/h step) 
30ml Syringe: 0.1ml/h ~ 900.0ml/h (0.1ml/h step) 
20ml Syringe: 0.1ml/h ~ 600.0ml/h (0.1ml/h step) 
10ml Syringe: 0.1ml/h ~ 300.0ml/h (0.1ml/h step) 
Flow Rate Accuracy Within ±3% (after correct calibration) 
Mechanical precision Within ±2% 
Bolus Rate 50/60ml Syringe: 1,200ml/h 
30 ml Syringe: 720ml/h 
20 ml Syringe: 480ml/h 
10 ml Syringe: 240ml/h 
Purge Rate 50/60ml Syringe: 1,500ml/h 
30ml Syringe: 900ml/h 
20ml Syringe: 600ml/h 
10ml Syringe: 300ml/h 
Volume Limit 0.1ml ~ 9999.9ml(0.1ml step) 
Total Injection 
Volume 
0.1ml ~ 9999.9ml (0.1ml step) 
Occlusion of Dual Channel Syringe Pump High: 800mmHg ±200mmHg (106.7kPa±26.7kPa 
Medium: 50/600mmHg ±100mmHg (66.7kPa±13.3kPa 
Low: 300mmHg ±100mmHg (40.7kPa±13.3kPa ) 
Alarms Injection soon finish, end of injection,occlusion, improperly installation of syringe, wrong setting, low battery, syringe loose etc. 
Power Source AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup 
KVO rate 1ml/h 
Fuse F1AL/250/60V, 2pcs inside 
Power Consumption 30VA 
IP Classification IPX4 
Equipment Classification Class II, internal power supply, Type CF 
Operating Condition Ambient temperature: +5ºC~ +40ºC 
Relative humidity 20 ~ 90% 
Transport & Storage Condition Ambient temperature:-30ºC~ +55ºC 
Relative humidity ≤95% 
Dimension 280mm (L) ×210mm(W) ×130mm(H) 
Weight 3.6kg (net weight) 
                          









Double Channel Syringe Pump with Drug Library
Double Channel Syringe Pump with Drug Library
Double Channel Syringe Pump with Drug Library
Double Channel Syringe Pump with Drug Library