China 11kw V5-H Reliable Frequency Drive, Find details about China AC Drives, Frequency Converters from 11kw V5-H Reliable Frequency Drive
Power(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Motor Power(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 3.5 | 6.2 | 9.2 | 14.9 | 21.5 | 27.9 | 39 | 50.3 | 60 | 69.3 | 86 | 104 | 124 | 150 | 201 | |
Braking unit | Built-in as standard | External braking unit needed | ||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Self-cooling | Forced air convection cooling |
Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ... | ... | ... | ... | ... | |
Motor Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ||||||
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 176 | 210 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | ||||||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 160* | 196* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | ||||||
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air convection cooling |
Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ... | ... | ... | ... | ... | |
Motor Power(KW) | 90 | 110 | 132 | 160 | 200 | 220 | 280 | 315 | 355 | 400 | ||||||
Output | Voltage(V) | Three-phase 0V to rated input voltage | ||||||||||||||
Rate current(A) | 176 | 210 | 253 | 304 | 377 | 415 | 520 | 585 | 650 | 740 | ||||||
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage unbalancedness ≤ 3%; allowable frequency fluctuation: ± 5% | |||||||||||||||
Rate current(A) | 160* | 196* | 232* | 282* | 352* | 385* | 491* | 552* | 624* | 704* | ||||||
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air convection cooling |