China Spilt Phase Pure Sine Wave Inverter 1000W 2000W 3000W 4000W 5000W 6000W with 120VAC / 220VAC Output, Find details about China Spilt Phase Inverter, 220VAC Inverter from Spilt Phase Pure Sine Wave Inverter 1000W 2000W 3000W 4000W 5000W 6000W with 120VAC / 220VAC Output
Winner sp Series | |||||||||||
Model | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | |
Input | Rated Capacity | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | 2KW | 30KW | 36KW | |
Commercial Power Range | 100V / 110V / 115V / 120V: 80VAC - 137VAC 200V / 220V /230V /240V: 160VAC - 275VAC | 200V / 220V / 230V / 240V: 160VAC - 275VAC | |||||||||
AC Frequency Range | 45 - 65Hz | ||||||||||
Efficiency | >85% | ||||||||||
Battery | Type | Lead-acid Battery / GEL Battery / Lithium Battery | |||||||||
DC Voltage | 12VDC / 24VDC | 24VDC / 48VDC | 48VDC / 96VDC | ||||||||
Input Voltage Range | 12VDC:10.5 - 15VDC 24VDC:21 - 30VDC 48VDC:42 - 60VDC 96VDC:84 - 120VDC | ||||||||||
Floating Charge Set | 12V:12.9 ~ 13.6V 24V:25.8V ~ 27.2V 48V:51.6V ~ 54.4V 96V:103.2V ~ 108.8 | ||||||||||
Low Voltage Restored | 12VDC:12.6 - 14.4VDC 24VDC:25.2 - 28.8VDC 48VDC:50.4 - 57.6VDC 96VDC:100.8 - 115.2VDC | ||||||||||
Low Voltage Shutdown Set | 12VDC:10 - 10.9V 24VDC:20 - 21.8V 48VDC:40 - 43.6V 96VDC:80V - 87.2V | ||||||||||
Over Voltage Protection | 12VDC:16.7VDC 24VDC:33.4V 48VDC:66.8V | ||||||||||
Over Voltage Alarm | 12VDC:15VDC 24VDC:30V 48VDC:60V | ||||||||||
AC Charging | 5A - 35A (40A, 50A, 60A, 70A, optional) | ||||||||||
Output | HOT1 + HOT2 | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10KW | 12KW |
HOT1 / HOT2+N | 500W | 750W | 1000W | 1500W | 2000W | 2500W | 3000W | 4000W | 5KW | 6KW | |
Capable of Starting Electronic Motor | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | ||||||
DC Mode Output | Output 1: HOT1 / HOT2 + N=100/110/115/120VAC ± 3% Output 2: HOT1 +HOT2=200/220/230/240VAC ± 3% | ||||||||||
AC Mode Output | Output 1: HOT1 / HOT2 + N = 100 / 110 / 115 / 120VAC Synchronize with AC Input Output 2: HOT1 + HOT2 = 200 / 220 / 230 / 240VAC Synchronize with AC Input | ||||||||||
Power Factor | 1 | ||||||||||
Transfer Time | Typical: 5 - 10ms (Including Detection Time) | ||||||||||
Temperature Protection | ≥85ºC Alarm ≥90ºC Machine Shut Off | ||||||||||
Overlord | IPS automatically shut down if overload exceeds 110% - 120% of normal value for 30 seconds, IPS automatically resume work if overload comes to rated load | ||||||||||
Wave Form | Pure sine wave | ||||||||||
Frequency | Commercial power supply: shared frequency with the commercial inversion state: 50/60Hz±0.5 | ||||||||||
Output Frequency Range (Electronic Supply Mode) | Tracking Automatically | ||||||||||
Protection | Overload, Short Circuit, Battery High and Low Voltage, AC Input High and Low Voltage Protection | ||||||||||
Conversion Method | Interactive | ||||||||||
Solar MPPT Controller (Optional) | MPPT Solar Controller | 30A / 50A | 50A / 60A / 80A | 80A / 100A | |||||||
Solar Input Power | 360W / 720W / 1200W | 1200W / 1440W / 2400W / 2880W / 3840W | 3840W /4800W / 9600W | ||||||||
Solar Input Voltage(Max) | 12VDC / 24VDC:100V 48VDC:160V 96VDC:200V or 280V | ||||||||||
Temperature | Operating Temperature | 0ºC ~ 70ºC | |||||||||
Thermal Method | Cooling fan in intelligent control ≤42ºC fan rotates slowly to ≥45ºC fan rotates fast | ||||||||||
Appearance | External Size(mm) (L*W*H) | 510*325*215 mm | 645*325*215 mm | 765*320*250 mm | |||||||
Gross Size(mm) (L*W*H) | 560*380*280 mm | 730*400*290 mm | 840*405*320 mm | ||||||||
Net Weight(KG) | 14 | 15 | 18 | 20 | 31 | 34 | 35 | 52 | 54 | 56 | |
Gross Weight(KG) | 16 | 17 | 20 | 22 | 35 | 37 | 38 | 56 | 58 | 60 | |
* Product Specification are Subject to Change Without Further Notice. |