Medical Portability Plasma Ozone Air Disinfectingmedical Hospital Equipment Sterilizer

China Medical Portability Plasma Ozone Air Disinfectingmedical Hospital Equipment Sterilizer, Find details about China Medical Equipment, Hospital Equipment from Medical Portability Plasma Ozone Air Disinfectingmedical Hospital Equipment Sterilizer

Port: Huangpu, China
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Certification: ISO9001, CE
Gas: Air
Frequency: 50-60Hz
Installation: Portable
Specification: 304 stainless steel
 

Advantages: 

While sterilizing, working personal can also stay in the sterilized room, The air sterilizer is can sterilize at any time, the disappearance rate of natural bacteria in the air is more than 95%, the manufacturer sells directly, the quality is guaranteed.
 

Installation mode: Mobile type

Purpose: The equipment is mainly used for disinfection and Purification of indoor air.

Disinfection effect : If the equipment works continuously for one hour, the extinction rate of natural bacteria in the air of 120m3 of room can be ≥ 91.81%. The killing rate of white staphylococcus in the 20m3 of laboratory was 99.99%.

High efficiency air purification: The built-in multi-stage filter combined with the plasma generator can remove benzene,  xylene, ammonia gas, smoke and so on and with a lot of negative ions fresh air.

Life of plasma generaton ≥ 25,000 hours

Plasma concentration: 1.24×1017-2.64×1017cm-3

Power requirement for working power : 220V 50Hz

Rated power (W) ≤60

Dynamic disinfection can be used in an environment where man and machine coexist,

and without generating secondary pollutants.

Ozone leakage rate ≤0.023mg/m3

Dynamic function can be used in the environment of man and machine coexistence,

and no secondary pollutants are generated


Medical Portability Plasma Ozone Air Disinfectingmedical Hospital Equipment Sterilizer
 

Working mode 

Three working modes : manual mode: The default disinfection time is 2 hours.

1)Manual mode: The default disinfection time is 2 hours.

2) Automatic mode: when the equipment detects low air quality or high dust particles indoor, it will automatically start the disinfection function.

3) Timing mode: According to needs, three time periods can be set, covering 24 hours of a day.

Display of accumulative working time

The machine has the memory function of accumulating working, and displays through LCD.

 

Quantity of SPC program and Coverage Time:

Three groups of SPC programs , covering 24 hours of a day.

The dimension is 515×405×840mm

Mobile UV air sterilizer _ Plasma air sterilizer _ medical air sterilizer

 

Medical Portability Plasma Ozone Air Disinfectingmedical Hospital Equipment Sterilizer

 

> > PRODUCT INTRODUCTION:

First generation disinfection by ozone 

Advantage: Carrying out complete sterilization to room without dead angle.

 

DISADVANTAGES:

While sterilizing, the people in the room will have to leave the room.

Second generation UV disinfection

Advantage: can man - machine coexist, and kill virus at any time.

Disadvantages: The equipment needs to be replaced by uv lamps every 2-3 years.

Third generation: plasma disinfection

Advantagecan man - machine coexistence, and absorb dust and microorganism in the air, released a large number of negative ion is captured by oxygen to become air vitamin - negative oxygen ion.

 

This machine = air sterilizer + air purifier

 

Scope of application

Medical Portability Plasma Ozone Air Disinfectingmedical Hospital Equipment Sterilizer

>>Disinfection effect

The extinction rate of natural bacteria in indoor air is more than 95%

The killing rate of white Staphylococcus in the air of fog chamber is more than 99%.

 

>>Features:

1.  Dynamic disinfection of indoor air can be carried out while 

     persons are in the room,no damage to both people and objects,

     and no secondary pollution to the environment;

2.  Using the plasma electrode with high and new technology and the application of

     inertial dust removal technology realizes broad-spectrum and efficient sterilization;

3.   Adding the synergistic effect of strong activated carbon and

      photocatalyst aluminum mesh combined filtration to degrades effectively and remove the peculiar smell,

      toxic and harmful gases and inhalable particles in the air;

4.    Consumable free, one time's investment can be used in lifetime.

5.    Long life, normal use is up to over eight years above.

6.    The sterilization rate of the air mist chamber is up to above 99.9%,

       and the sterilization rate of the natural bacteria in the air is above 90%

7.    Test results On the the value of killing bacteria is 200 cfu /m³

8.    Residual acuities of ozone is 0.2 mg /m³

9.    Intelligent program control technology, 3 sterilization working.

       periods can be booked at will every day, and the machine can be switched on and off automatically;

10.  Wind speed optional: High, medium and low.

11.   Anion generator, fresh air,automatic fault alarm;

12.   Three levels of filtration and dust removal,sterilization of  primary, medium and high efficiency.  

13.   Remote infrared ray control.

14.   Automatic Prompt alarm of plasma generator, electrostatic field fault.
 

Medical Portability Plasma Ozone Air Disinfectingmedical Hospital Equipment Sterilizer

 

>> Disinfection effect

The extinction rate of natural bacteria in indoor air is more than 95%

The killing rate of Staphylococcus white in the air of fog chamber is more than 99%

 

>> Features:

1.    Use the plasma electrode with high and new technology,

       and the application of inertial dust removal technology, broad-spectrum efficient sterilization;

2     Add the synergistic effect of strong activated carbon and

       photocatalyst aluminum mesh combined filtration to degrade effectively and remove the peculiar smell,

       toxic and harmful gases and inhalable particles in the air;

3.    Consumption-free, once put into lifelong use;

4.    Long life, normal use up to 8 years;

5.    The sterilization rate of the air mist chamber is above 99.9%,

       and the sterilization rate of the natural bacteria in the air is above 90%

6.    The site test results: boot colony count < 200 cfu /m³

7.    Ozone residual acuities were 0.2 mg / m³

8.    Intelligent program control technology, 3 sterilization working  periods can be booked at will every day,

       and the machine can be switched on and off automatically;

9.    Choose high, medium and low wind speeds;

10.  Anion generator, fresh air, automatic fault alarm;

11.  Primary, medium and high efficiency three-stage filtration, dust removal and sterilization;

12.  Remote infrared ray operation can be realized;

13.  Automatic prompt and alarm for plasma generator and  electrostatic field faults