Horizontal Concealed Fan Coil Unit with Longevity DC Motor

China Horizontal Concealed Fan Coil Unit with Longevity DC Motor, Find details about China Fan Coil, DC Motor Fan Coil from Horizontal Concealed Fan Coil Unit with Longevity DC Motor

Model NO.
EST800HC2
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE, CCC
Condition
New
Motor
Panasonic DC Motor
Pipe System
Two Pipe and Four Pipe System
Air Outlet Static Pressure
0,12, 30,50PA
Plenum Box
Backward or Downward
Trademark
Eurostars
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
84159010
Model NO.
EST800HC2
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE, CCC
Condition
New
Motor
Panasonic DC Motor
Pipe System
Two Pipe and Four Pipe System
Air Outlet Static Pressure
0,12, 30,50PA
Plenum Box
Backward or Downward
Trademark
Eurostars
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
84159010
Horizontal Concealed Fan Coil Unit with Longevity DC Motor

1.  DC horizontal concealed fan coil features:
(1)Low noise-high quality reliability DC fan motor;
(2) High efficient and energy saving-seamless copper tube mechanically expanded to aluminum shutter fins;
(3) V shape designed drainage pan;
(4)Professional designed water connector;
(5) Flexible installation and easy operation.

In central air conditioner system, Eurostars ceiling duct horizontal concealed fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Vertical floor standing fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Eurostars DC horizontal concealed fan coil main components introduction:
Horizontal Concealed Fan Coil Unit with Longevity DC Motor

3. Eurostars horizontal concealed ducted fan coil nomenclature

ES  T   200    HC2     C     R      B  A    O   
1    2      3       4         5      6     7    8   9 
1: ES Eurostars
2 :T Terminal series
3 :200 Rated air flow: CFM
4 :HC2 Horizontal exposed and the number of tube system
5 :C Coil type:  C-3C0H; T-2C0H (Note: C-Cold water coil; H-Hot water coil)                                    
6 :R Connection pipe direction: R-Right (face to air outlet)  L-Left (face to air outlet)
7 :B Return air box type: C-None;  B-Backward return air box  D-Downward return air box
8: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
9 :O Sales region: O-Other regions;  C-Mainland China

4. Eurostars DC ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system)
Model EST~200HC2300HC2400HC2500HC2600HC2800HC21000HC21200HC21400HC2
Air flow (m3/h)
(12Pa,30Pa Static Pressure)
Max.34051068085010201360170020402380
Min.130170220260300400600700760
Rated cooling capacity HTH(W)18002700360046205400720090001080012600
SH(W)134120122682335340235364670580469387
LTH(W)89511701514178920652753412948185231
SH(W)561734949112212951726258930213280
Rated heating capacity Max.W2700405054006750810010800135001620018900
Min.134217552271268430974129619472267846
Power input high speed (W)12Pa1518273342546582100
30Pa1722293545687088108
Noise high speed dB(A)12Pa34 35 36 38 41 42 43 44 46 
30Pa373941424546484951
Heat exchangerWater flowm3/h0.31 0.46 0.62 0.77 0.93 1.23 1.54 1.85 2.16 
TypeCopper tubes with shutter-type aluminum fins
Max working pressure1.6MPa
Testing pressureAirtightness test under pressurized water: 3.3MPa
Pressure drop (KPa)161820232830333740
FanType Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates
Qty122224444
MotorTypeSingle-phase capacitive motor equips with fine ball bearing, low noise and long service life
Qty111112222
Power supply220V-/50HZ
Protection gradeIP20
Insulation classB
Pipe Inlet/outlet water pipeZG 3/4 " (DN20)
Condensation water pipeZG 3/4"   (DN20)
 Net weight Kgwithout plenum
 air box
13.00 15.00 16.00 17.00 19.00 22.00 29.00 31.00 34.00 
with plenum
air box 
15.50 17.80 20.00 21.90 23.30 32.30 35.70 40.00 44.90 

(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature  60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.

5.DC horizontal concealed fan coil unit energy saving curves
Horizontal Concealed Fan Coil Unit with Longevity DC Motor

6. Horizontal concealed fan coil unit wiring and installation instruction
Horizontal Concealed Fan Coil Unit with Longevity DC Motor


7. Horizontal concealed fan coil unit dimensions and exploded views
Horizontal Concealed Fan Coil Unit with Longevity DC Motor

8. Eurostars fan coil unit series
((1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit