Top Plunger Limit Switch with Automatic Reset (LX19-001)

China Top Plunger Limit Switch with Automatic Reset (LX19-001), Find details about China Limit Switch, Switch from Top Plunger Limit Switch with Automatic Reset (LX19-001)

Model NO.
LX19-001
Conventional Thermal Current
5A
Electrical Prameter
AC380V/0.8A DC220V/0.1A
Vibration
Malfunction:10Hz~55Hz, 1.5mm Double Amplitude
Shock
Mechanical Resistance:1000m/S2; Malfunction:300m/S
Working Life
Mechanical:6*106 Min.; Electrical:3*105
Degree of Protection
IP52
Ambient Temperature
Minus 5 to 60 Centigrades
Trademark
CLIN
Origin
Wenzhou, China
HS Code
8536500000
Model NO.
LX19-001
Conventional Thermal Current
5A
Electrical Prameter
AC380V/0.8A DC220V/0.1A
Vibration
Malfunction:10Hz~55Hz, 1.5mm Double Amplitude
Shock
Mechanical Resistance:1000m/S2; Malfunction:300m/S
Working Life
Mechanical:6*106 Min.; Electrical:3*105
Degree of Protection
IP52
Ambient Temperature
Minus 5 to 60 Centigrades
Trademark
CLIN
Origin
Wenzhou, China
HS Code
8536500000
Limit Switch(LX19-001)
General Introduction

LX-19 series limit switch is applied to the 50HZ/60HZ, 250VAC, 220VDC control circuits, works as travel control, limit control, motion direction or speed change, machine tool automatic control, etc.
Approved standards: GB14048.5 IEC60947-5-1
Top Plunger Limit Switch with Automatic Reset (LX19-001)Top Plunger Limit Switch with Automatic Reset (LX19-001)
Main Technical Specification
 
Operating Speed0.5mm~0.5m/s
Operating FrequencyMechanical:120 operations/min;Electrical:30 operations/min
Contact Resistance50mΩ max (initial value)
Insulation Resistance100mΩ min(at 500VDC)
Conventional Thermal Current5A
Electrical PrameterAC380V/0.8A DC220V/0.1A
Dielectric Strength1890V, 50/60Hz for 1min between terminals of the same polarity
2500V, 50/60Hz for 1 min between terminal and non-current carrying metal parts
2500V, 50/60Hz for 1 min between terminal and ground
Vibrationmalfunction:10Hz~55Hz, 1.5mm double amplitude
Shockmechanical resistance:1000m/s2; malfunction:300m/s2
Ambient EnvironmentTemperature:minus5centigrade~60 centigrade(no ice); Humidity:<90%RH
Working LifeMechanical:6*106 Min.; Electrical:3*105
Degree of ProtectionIP52

Operating Characteristics
TypeOperating Force maxPretravel maxOvertravel min
LX19-K10N(1.02kgf)3.5mm0.5mm
LX19-00116N(1.63kgf)7mm2mm
LX19-11120N(2.04kgf)45°15°
LX19-12120N(2.04kgf)45°15°
LX19-13120N(2.04kgf)45°15°
LX19-21225N(2.55kgf)80°/
LX19-22225N(2.55kgf)80°/
LX19-23225N(2.55kgf)80°/
Top Plunger Limit Switch with Automatic Reset (LX19-001)