Ceyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&S

China Ceyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&S, Find details about China Spectrum Analyzer, Signal Analyzer from Ceyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&S

Model NO.
4051C-S
Warranty
3 Year Warranty
Power Source
AC 100-240V
Weight
25kg
Installation
Direct Connected
Customized
Non-Customized
Trademark
Ceyear
Transport Package
Aluminum Transportation Case
Specification
W*H*D= 510mm*190mm*534mm
Origin
China
HS Code
9030849000
Model NO.
4051C-S
Warranty
3 Year Warranty
Power Source
AC 100-240V
Weight
25kg
Installation
Direct Connected
Customized
Non-Customized
Trademark
Ceyear
Transport Package
Aluminum Transportation Case
Specification
W*H*D= 510mm*190mm*534mm
Origin
China
HS Code
9030849000
Product Overview:
4051-S Series Signal/Spectrum Analyzers can give you incomparable spectrum testing services of high price-performance ratio. The analyzers he excellent dynamic range, phase noise, amplitude precision and testing speed, can supply ten testing functions in total including high-performance spectrum analysis, spectral power test modules conforming to relevant criteria etc. Capabilities of the analyzers can be greatly augmented. Multiple practical options are ailable like preamplifier, phase noise testing, random IF output and so on. 4051 Series can be widely applied in signal and instrument tests relating to fields of aerospace, communication, EMC, radar detection, nigation, etc.  

Ceyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&SCeyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&SCeyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&S

Main Features:
1. Incomparable price-performance ratio
2. 5 frequency range, up to 26.5GHz
3. Excellent testing & receiving performance
4. Comprehensive spectrum analysis capability 
5. Practical function options
6. Easy & convenient operation

Ceyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&SCeyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&SCeyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&S

Typical Applications:
1. RF performance assessment of electronic systems: as universal spectrum   analyzers of multiple functions, 4051-S Series Signal/Spectrum analyzers can be widely used in RF performance evaluative of electronic systems in  fields like radar, communication and so on. They can provide high sensitivity, wide dynamic range, high precision and efficiency resolutions.
2. Test and diagnosis of transmitter and receiver: 4051-S Series can furnish  comprehensive common diagnosis services for transmitter and receiver by the multiple functions of spectrum analysis, spectral power testing, and phase  noise testing and so on.  
3. Can be directly used for the integration of complex test and diagnosis systems, and give you test results of spectrum characteristics and signal output.

Ceyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&SCeyear 4051c-S Signal/Spectrum Analyzer 3Hz~13.2GHz Equivalent to Keysight R&S

Technical Specifications:
Model4051A-S/4051B-S/4051C-S/4051D-S/4051E-S
Frequency range3Hz~4GHz/9GHz/13.2GHz/18GHz/26.5GHz
10MHz
Precision frequency reference
Frequency accuracy:  ±(last calibration time × aging rate+temp stability+calibration accuracy)
Aging rate:     ± 1´10-7/Y
Temp stability:  ± 1´10-8(20°C ~ 30°C)    ± 5´10-8(0°C ~ 55°C)
Calibration accuracy:  ± 7´10-8
Frequency readout accuracy±(Frequency readout × frequency reference accuracy+0.1% frequency bandwidth +5% resolution bandwidth+2Hz+0.5 horizontal resolution *) 
*:horizontal resolution =frequency bandwidth/(sweep points-1)
Frequency counting accuracy±(frequency readout × frequency reference accuracy+0.1Hz)
Frequency bandwidthRange:0Hz(zero frequency bandwidth),10Hz~the maxim frequency range of this model
Accuracy: ±(0.1%×frequency bandwidth+frequency bandwidth/(sweep points-1))
Sweep time rangeFrequency bandwidth≥10Hz:   1ms~4000s
Frequency bandwidth=0Hz:    1us~6000s
Resolution bandwidthRange:1Hz~3MHz (1,2,3,5 stepping),4,5,6,8,10MHz
Conversion uncertainty: £ ± 0.3dB
Video bandwidth1Hz~3MHz (1,2,3,5 stepping),4,5,6,8,10MHz(rated value)
Trigger modeFree, power source, video, external level (front panel), external level (rear panel), burst  RF, timer
Detection modeNormal, positive peak, negative peal, sampling, erage, root mean square
erage modesVideo erage, power erage, level erage
SSB phase noise
(1GHz carrier,20°C ~ 30°C)
-92dBc/Hz      100Hz
-105dBc/Hz     1kHz
-118dBc/Hz     10kHz
-123dBc/Hz     100kHz
  Residual FM
(central frequency 1GHz,resolution bandwidth10Hz,video bandwidth 10 Hz)
≤(0.25 Hz x N) p-p,rated value within 20 ms
N is frequency multiplication times of LO
Displayed erage noise level (the input end is connected to match load, sampling or erage we detection. The erage type is logarithm, 0dB input attenuation, RF gain takes the sensitivity as the priority)-153dBm/Hz     10MHz~1GHz
-151dBm/Hz     1GHz~2GHz
-150dBm/Hz     2GHz~3GHz
-148dBm/Hz     3GHz~3.6GHz
-145dBm/Hz     3.6GHz~4GHz
-148dBm/Hz     4GHz~4.4GHz
-150dBm/Hz     4.4GHz~9GHz
-146dBm/Hz     9GHz~18GHz
-141dBm/Hz     18GHz~26.5GHz
Frequency response & absolute amplitude accuracy
(10dB attenuation,
20°C ~ 30°C)
Frequency response:
<±0.8dB       3Hz~3.6GHz
< ±1.0dB       3.6GHz~4GHz
< ±1.5dB       4GHz~9GHz
< ±2.0dB       9GHz~18GHz
< ±2.5dB       18GHz~26.5GHz
Absolute amplitude accuracy 10 dB attenuation, 20°C ~ 30°C,1 Hz ≤ resolution bandwidth ≤ 1 MHz, input signal-10 ~ -50 dBm):
±0.24dB                  500MHz
±(0.24dB+frequency response)    All frequencies
1dB gain compression(mixer level, dual-tone testing, resolution bandwidth of 5kHz,frequency interval of 3MHz,20°C ~ 30°C)-3dBm       20MHz~40MHz
0dBm        40MHz~200MHz
+1dBm       200MHz~4GHz
- 1dBm       4GHz~9GHz
0dBm        9GHz~26.5GHz
Tri-order intermodulation distortion
(TOI)
(input 2 signals of -10dBm into the mixer for testing, frequency interval is 50kHz, 20ºC~30ºC)
< +12dBm     10MHz ~ 4GHz
< +10dBm     4GHz ~ 9GHz
< +12dBm     9GHz ~ 18GHz
< +13dBm     18GHz ~ 26.5GHz
Residual response
(the input end is connected to match load, 0dB attenuation)
-100dBm               200kHz~9GHz
-100dBm (rated value)     Other frequencies
DimensionsW×H×D= 510mm×192mm×534mm  (with handles, foot-pads, bottom feet)
W×H×D= 426mm×177mm×460mm  (without handles, foot-pads, bottom feet)
WeightApprox. 25kg (different options, different weight)
PowerAC 220/240V:50/60Hz
Power consumptionStandby is below 20W;Working is below 400W
Temp rangeWorking temp 0°C ~ +50°C ; Storage temp: -40°C ~ +70°C
Input connector4051A-S/4051B-S /4051C-S /4051D-S:type N(F),impedance 50Ω
4051E-S:3.5mm(M),impedance 50Ω
Order:  
1. Rated value refers to the estimated performance, or the performance which is useful for the product beyond the quality guarantee scope.
2. Typical value refers to other performance information when typical values stay beyond   the quality guarantee scope. When performance surpasses technical specifications, 8    0% of samples will present 95% confidence within 20°C ~ 30°C temperature range. Typical performance excludes test uncertainty.