Shenda ( In full: Shenda Electric Group Co.,Ltd.) is one of the leading manufacturers in the power transmission & distribution industry. Founded in 2000 and currently employs about 1,100 employees worldwide. Shenda operates four factories (three in China and one in the United States of America - R. E. Uptegraff Manufacturing Company, LLC of Pennsylvania, U.S.A.). Shenda also owns other ten subsidiaries throughout China. The annual gross sales is USD$250 million in 2015.Shenda's annual total production capacity is about 18,000,000 KVA, Our main products include oil immersed power transformer(up to 250MVA/ 330kV) , dry type transformer(up to 20MVA/35kV), combined transformer substation, amorphous alloy transformer, rectifier transformer (100MVA/220kV )and especially furnace transformer(180MVA/220kV). Our products' performance measures up to the standards established by International Electric Committee (IEC).
shendaelectric.en.made-in-china.com
Product serie
Mobile Substation SpecificationsYB Series Cubicle Substation
Serialization, modularization, multiple functions, complete facility, small volume.
Main function and FeaturesThe product consists of HV distribution unit, and LV distribution unit and is divided into HV chamber, transformer chamber and LV. The HV chamber has complete functions, it with HXGN-10 ring main unit forms the primary supply system, may be arranged into several supply modes( ring main supply, terminal supply and dual-source supply) and also may be provided with HV metering elements to meet requirements on HV metering. Model S9, S11 and other low loss oil-immersed transformers or dry transformers else may be selected. The transformer chamber is designed to have automatic forced air cooling system and lighting system. The LV chamber can constitute user-required power supply schemes in a panel type or cabinet type structure, provide several functions (Power distribution, lighting distribution reactive power compensation, and metering of electrical power) to meet users' different requirements. And facilitate supply management and improve power supply quality.
The HV chamber is compact in structure and is provided with mis-operation preventive interlocking function. Each chamber has automatic and forced lighting device. In addition, all elements in HV and LV chamber are reliable in performance and easy in operation, which makes the products safe and reliable and easy in operation and maintenance.
It adopts both natural ventilation and forced ventilation to each good ventilation and cooling effects. The transformer chamber and LV chamber are provided with air ducts. The blower fan has a temperature controller to automatically start and stop as per the preset temperature, thus ensuring on load running of transformer.
The casing body prevents rain water and foreign matter from entrance and it is made of hot-galvanized color steel sheet or anti-rust aluminum alloy sheet and subjected to anti-corrosion treatment. It looks artistic, keeps long-term corrosion, water and dust-proof under outdoor conditions, and prolong service life or transformer.
This products have following characters: Serialization, modularization, multiple functions, complete facility, small volume, light weight and good looking. They meet the requirement of IEC1330 standard and applicable to city public distribution, street lamp power supply, as well as power consumption in industrial /mineral enterprises, high-rises, residential areas, oil fields, jetty and site construction.
Main function and Features
The product consists of HV distribution unit, and LV distribution unit and is divided into HV chamber, transformer chamber and LV. The HV chamber has complete functions, it with HXGN-10 ring main unit forms the primary supply system, may be arranged into several supply modes( ring main supply, terminal supply and dual-source supply) and also may be provided with HV metering elements to meet requirements on HV metering. Model S9, S11 and other low loss oil-immersed transformers or dry transformers else may be selected. The transformer chamber is designed to have automatic forced air cooling system and lighting system. The LV chamber can constitute user-required power supply schemes in a panel type or cabinet type structure, provide several functions (Power distribution, lighting distribution reactive power compensation, and metering of electrical power) to meet users' different requirements. And facilitate supply management and improve power supply quality.
Configuration | Power (kVA) | W | H | D | W1 | D1 | D2 | H1 | Weight (kg) |
Standard π configuration | ≤125 | 2000 | 1580 | 1116 | 1180 | 508 | 575 | 1240 | 2000 |
160~500 | 2000 | 1580 | 1350 | 1330 | 508 | 655 | 1340 | 2950 |
630 | 2000 | 1710 | 1560 | 1420 | 632 | 775 | 1480 | 3400 |
800 | 2000 | 1710 | 1690 | 1420 | 632 | 775 | 1480 | 3600 |
1000 | 2000 | 1710 | 1820 | 1420 | 632 | 815 | 1480 | 4000 |
1250 | 2000 | 1710 | 1840 | 1560 | 632 | 795 | 1480 | 4800 |
1600 | 2205 | 1710 | 1920 | 1680 | 632 | 920 | 1520 | 5700 |
Extra π configuration | ≤125 | 2200 | 1900 | 1240 | 1180 | 632 | 575 | 1240 | 2200 |
160~500 | 2200 | 1900 | 1474 | 1330 | 632 | 655 | 1340 | 3150 |
630 | 2200 | 1900 | 1560 | 1420 | 632 | 775 | 1480 | 3600 |
800 | 2200 | 1900 | 1690 | 1420 | 632 | 775 | 1480 | 3800 |
1000 | 2200 | 1900 | 1780 | 1420 | 632 | 815 | 1480 | 4200 |
Certifications100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China
120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands
63MVA/110KV Power transformer short circuit test report
-issued by CTQC China
12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea
Test labTesting are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
- Measurement of winding resistance .
- Measurement of voltage ratio and check of phase displacement.
- Measurement of short circuit impedance and load losses.
-Measurement of no-load losses and current .
-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .
B - Type tests :
The following tests shall be carried out
- Temperature rise test
- Lightning impulse test
C - Special tests :
- Determination of noise level according to IEC 60551 .
- Oil leakage test
- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).
Client inspection
Factory documentation 1 | Technical parameters |
2 | Outline drawing |
3 | Lifting diagram |
4 | Nameplate drawing |
5 | Control box drawing |
6 | Transportation diagram |
7 | Transformer install manual |
8 | Transformer operation / Maintenance instruction |
9 | Principles parts / components ex-work certification and operation instruction |
10 | Recommended spare part for 2-5 years operation |
11 | Test reports (routine test / type test / special test) |
12 | Etc… |
Engineering ServicesDuring the design process, client will be permitted to come to factory to take a supervision and guidance, manufacture and acceptance test. We provide engineering services like pre-commissioning / commissioning / install and operation consult support / technicians training on site. We provide after-sales service.We provide 12 months warranty of quality and performance