12V 100A Battery Testing Equipment/Battery Regenerator and Discharger for Lead Acid Stationary Battery

China 12V 100A Battery Testing Equipment/Battery Regenerator and Discharger for Lead Acid Stationary Battery, Find details about China Battery Regenerator, Battery Charge Discharge Maintenance Tester from 12V 100A Battery Testing Equipment/Battery Regenerator and Discharger for Lead Acid Stationary Battery

Model NO.
EPFH
Cell Voltage Resolution
1.2V/2V/6V:0.001V 12V:0.01V
Voltage Test Precision
0.5%
Charge/Discharge Current
2V:2A~100A 6V:2A~30A 12V:2A~30A
Current Control Precision
0.1A
Current Test Precision
1%
Battery Volume Range
AC 220+/-15%
Communication Way
RS232 & USB
Cooling Way
Air Cooling
Working Condition
Temperature:0~40 Humidity:20%~80%Rh
Display
Color LCD Display
Weight
10kg
Carry Way
Portable
Maintain Condition
-20~70 Store It with Package
Trademark
EP Hipot Electric
Transport Package
Plywood
Specification
280*210*240mm
Origin
China
HS Code
9030899090
Model NO.
EPFH
Cell Voltage Resolution
1.2V/2V/6V:0.001V 12V:0.01V
Voltage Test Precision
0.5%
Charge/Discharge Current
2V:2A~100A 6V:2A~30A 12V:2A~30A
Current Control Precision
0.1A
Current Test Precision
1%
Battery Volume Range
AC 220+/-15%
Communication Way
RS232 & USB
Cooling Way
Air Cooling
Working Condition
Temperature:0~40 Humidity:20%~80%Rh
Display
Color LCD Display
Weight
10kg
Carry Way
Portable
Maintain Condition
-20~70 Store It with Package
Trademark
EP Hipot Electric
Transport Package
Plywood
Specification
280*210*240mm
Origin
China
HS Code
9030899090
General Information:
EPFH Battery Intelligent Regenerator (also called Battery Regenerator & Discharge Cycler) has 3 independent test methods: battery discharge, battery charge and battery rejuvenation. Focusing on the different situation of lag single battery, EPFH can do a discharge test to estimate the real capacity, intelligent charge the battery, and set multiple cycles included discharge and charge to activate the lag battery. It can upload the discharge and charge testing data to PC. In the software you can analyze the quality problem of the lag battery.

Main Functions:
  • Single battery rejuvenation :
When the battery is in the online floating charge or offline state, the single battery can be activated. Before regeneration, set the number of regeneration cycles, single regeneration charging time, and protection voltage parameters. The regenerator will automatically activate the function and display the battery voltage, charge/discharge current, charge/discharge capacity, charge/discharge time and other data in real time. The regeneration process can be stopped when the preset regeneration cycle is completed or the operation is terminated manually.
 
  • Cell check discharge:
The regenerator can discharge the single battery at a constant current, set the discharge current, discharge time, discharge capacity, termination voltage and other parameters. The instrument automatically executes the discharge function, and displays the discharge current, battery discharged capacity, battery voltage, and discharge in real time and other data. The discharge test can be stopped when the battery reaches the preset termination discharge condition or the operation is manually suspended.
 
  • Cell charge:
When the battery is being charged or offline it can charge the battery automatically. Set power, time, ending voltage, etc. the instrument will begin charge automatically and display power, volume, voltage, time, etc. When battery achieves set aim it can stop discharge itself or by manual


Main Features:
  • Data storage: large capacity. Save 10 groups of regeneration data, 10 groups of check discharge data, and 10 groups of charge test data. Users can query, delete and export the data.
  • With RS232 interface and USB interface. users can perform long-term historical data storage and analysis.
  • When the instrument detects abnormal phenomenon of battery or working is abnormal, it automatically stops testing for protecting battery.
  • The regeneration adopts integrated design with monitoring unit and power unit. The monitoring unit adopts high-speed A/D and D/A, and power unit adopts new-type parts.
  • This software is English designed, and it can automatically create voltage/current histogram, curve chart, and test report (including Excel table and WORD document).

Main technical data table:
 
Cell voltage1.2V/2V/6V/12V
Cell voltage range2V:0~3V    6V:4~8V12V:8~15V
Cell voltage resolution 1.2V/2V/6V:0.001V
12V:0.01V
Voltage test precision0.5%
Charge/Discharge current2V:2A~100A6V:2A~30A12V:2A~30A
Current control precision0.1A
Current test precision1%
Battery volume range20Ah~1000Ah6V:20Ah~300Ah12V:20Ah~300Ah
Working voltageAC 220±15%
Communication wayRS232 & USB
Cooling wayAir cooling
Working conditionTemperature:0ºC~40ºC    Humidity:20%~80%RH
Maintain condition-20ºC~70ºC  Store it with package
DisplayColor LCD display
Dimension280×210×240mm
Weight10kg
Carry wayPortable



More details about EPFH Series Battery Tester, please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.

12V 100A Battery Testing Equipment/Battery Regenerator and Discharger for Lead Acid Stationary Battery
12V 100A Battery Testing Equipment/Battery Regenerator and Discharger for Lead Acid Stationary Battery