China 12V 100A Battery Testing Equipment/Battery Regenerator and Discharger for Lead Acid Stationary Battery, Find details about China Battery Regenerator, Battery Charge Discharge Maintenance Tester from 12V 100A Battery Testing Equipment/Battery Regenerator and Discharger for Lead Acid Stationary Battery
Cell voltage | 1.2V/2V/6V/12V | ||
Cell voltage range | 2V:0~3V | 6V:4~8V | 12V:8~15V |
Cell voltage resolution | 1.2V/2V/6V:0.001V 12V:0.01V | ||
Voltage test precision | 0.5% | ||
Charge/Discharge current | 2V:2A~100A | 6V:2A~30A | 12V:2A~30A |
Current control precision | 0.1A | ||
Current test precision | 1% | ||
Battery volume range | 20Ah~1000Ah | 6V:20Ah~300Ah | 12V:20Ah~300Ah |
Working voltage | AC 220±15% | ||
Communication way | RS232 & USB | ||
Cooling way | Air cooling | ||
Working condition | Temperature:0ºC~40ºC Humidity:20%~80%RH | ||
Maintain condition | -20ºC~70ºC Store it with package | ||
Display | Color LCD display | ||
Dimension | 280×210×240mm | ||
Weight | 10kg | ||
Carry way | Portable |