Amorphous Alloy Core Distribution Transformer

China Amorphous Alloy Core Distribution Transformer, Find details about China Oil-Immersed, High-Pressure from Amorphous Alloy Core Distribution Transformer

Model NO.
SBH15-M
Origin
Yangzhou, Jiangsu, China
HS Code
850422000
Model NO.
SBH15-M
Origin
Yangzhou, Jiangsu, China
HS Code
850422000
Amorphous Alloy Core Distribution Transformer

Product Introduction

This product implements national standards GB 1094- 1996 the power transformer "and GB/T6451-2008 the three-phase oil-immersed power transformer technical parameters and requirements".

S11 series transformer is the latest series of low loss copper windings products, the products using high-quality materials, in coil implement body and insulation, using new craft, new material, thus made racing, load loss reduced significantly, and performance and structure more reliable and superior.

Product Features

*Good economic performance
On the basis of S9 series, the no-load loss of S11-S13 series products is reduced by 30% on average, and the no-load current is reduced by 70%-85% compared with S9 series..
*Long service life
Transformer tank adopts fully sealed structure, which can be bolted or welded along the tank. Transformer oil does not contact with air and prolongs service life.
*Running high reliability
Improving the concerned tank sealing parts, increasing reliability improvements to ensure and improve technology level of reliability of sealing.
*Floor area is small
S11-M, S13-M series transformer tank adopts wave plate radiator, when the oil temperature change, the corrugated plate heat bilges cold shrink can replace storage cabinet role, corrugated plate appearance tank looks nice and covers small area .

Model Description

S11 10kv/20kv/35kv Oil Immersed High Voltage Non-Exciting Power Distribution Transformer
Product Description 
110kv 220kv Oil-Immersed High-Pressure Low-Loss Low-Noise Energy-Conservation Transformer
Work Shop
110kv 220kv Oil-Immersed High-Pressure Low-Loss Low-Noise Energy-Conservation TransformerAmorphous Alloy Core Distribution TransformerAmorphous Alloy Core Distribution TransformerAmorphous Alloy Core Distribution TransformerAmorphous Alloy Core Distribution TransformerAmorphous Alloy Core Distribution Transformer

Technical Data of Three- -phase Duplex Winding Power Transformer On-load Changer
Rated Capacity
(kVA)
Voltage CombinedVector- groupNo-load Loss
(kw)
load Loss (kw)
75ºC
No-load
current (%)
Short- circuit
impedance (%)
HV(KV)LV(KV)
6300110±
8×1.25%
6.3
6.6
10.5
11
YNd1110.0360.8010.5
800012.0450.80
1000014.2530.74
1250016.8630.74
1600020.2770.69
2000024.0930.69
2500028.41100.64
3150033.81330.64
4000040.41560.58
5000047.81940.58
6300056.82340.52

Technical Data of Three- -phase Three Winding Power Transformer On-load Changer
Rated Capacity (kVA)Voltage CombinedVector- groupNo-load Loss (kw)load Loss (kw)
75ºC
No-load
current (%)
Short- circuit
impedance (%)
HV(KV)MV(KV)LV(KV)
6300110±
8×1.25%
35
37
38.5
6.3
6.6
10.5
11
YNyn0d1112.0470.95H-M
10.5
H-L
17.5-18.5
M-L
6.5
800014.4560.95
1000017.1660.89
1250020.2780.89
1600024.2950.84
2000028.61120.84
2500033.81330.78
3150040.21570.78
4000048.21890.73
5000056.92250.73
6300067.72700.67
1. 10 type products: no-load loss fell by 10 percent; Load loss by 5 per cent.
2. 11 type products: no-load loss dropped 20%; Load loss by 5 per cent.

Technical Data of Three- -phase Three Winding Non-field Excitation Changer Self Coupling Power Transformer
Rated Capacity (kVA)Voltage CombinedVector- groupStep-up CombinationStep-down CombinationShort- circuit
impedance
HV(KV)MV(KV)LV(KV)No-load Loss (kw)load Loss (kw)
75ºC
No-load
current (%)
No-load Loss (kw)load Loss (kw)
75ºC
No-load
current (%)
Step-upStep-down
31500





220±
2×2.5%

242±
2×2.5%







115

121
6.6
10.5
11
35
37
38.5
YNa0d11251170.5722990.50H-M
12-14
H-L
8-12
M-L
14-18
H-M
8-10
H-L
28-34
M-L
18-24
40000291440.57261210.50
50000341700.50301440.43
63000402010.50361710.43
90000502760.43462340.36
12000010.5
11
13.8
15.75
18
35
37
38.5
623400.43562880.36
150000734050.36663420.33
180000844630.36763870.33
240000995950.33895040.25

Technical Data of Three- -phase Duplex Winding Power Transformer On-load Changer
Rated Capacity (kVA)
 
Voltage CombinedVector- groupNo-load Loss
(kw)
load Loss
75ºC(kw)
No-load
current (%)
Short- circuit
impedance (%)
HV(KV)LV(KV)
31500220±
8×1.25%
6.3
6.6
10.5
11
35
37
38.5
YNd11381350.7012-14
40000451570.63
50000541890.56
63000632200.56
90000802880.49
12000010.5
11
35
37
38.5
993460.49
1500001164050.42
1800001354680.42
12000066
69
1023550.49
1500001204150.42
1800001404750.42

Technical Data of Three- -phase Three Winding Power Transformer On-load Changer
Rated Capacity
(kVA)
Voltage CombinedVector- groupNo-load Loss
 (kw)
load Loss (kw)
75ºC
No-load
current (%)
Capacity
assignment(%)
Short- circuit
impedance (%)
HV(KV)MV(KV)LV(KV)
31500220±
8×1.25%
69
115
121
6.3
6.6
10.5
11
35
37
38.5
YNyn0d11441620.77100/100/100
100/50/100
100/100/50
H-M
12-14
H-L
22-24
M-L
7-9
40000521890.70
50000602250.63
63000702610.63
9000010.5
11
35
37
38.5
923510.56
1200001154320.56
1500001355130.49
1800001566300.49
2400001937800.45
 
Technical Data of Three- -phase Three Winding On-load Changer Word Coupling Power Transformer
Rated Capacity (kVA)Voltage CombinedVector- groupNo-load Loss (kw)load Loss (kw)
75ºC
No-load
current (%)
Capacity
assignment(%)
Short- circuit
Impedance (%)
HV(KV)MV(KV)LV(KV)
31500220±
8×1.25%
115
121
6.3
6.6
10.5
11
35
37
38.5
YNa0d11251080.56100/100/50H-M
8-10
H-L
28-34
M-L
18-24
40000301320.56
50000361570.49
63000421890.49
9000010.5
11
35
37
38.5
512470.42
120000643070.42
150000763650.35
180000854190.35
2400001045400.30
1. 10 type products: no-load loss fell by 10 percent; Load loss by 5 per cent.
2. 11 type products: no-load loss dropped 20%; Load loss by 5 per cent.

FAQ
Q: What certificates and standard does your company have?
A: Our factory has ISO9001:2008, ISO14001:2004, OHSAS18001:2007 certificates. 
We can send products to appointed laboratories for testing if necessary.
Q: How long is your delivery time?
A:For 10KV distribution transformer, the production cycle of our factory is 20~25 days.
Q: What is your service?
A: we have quick response in before sales period help you got order, and excellent service in production time let you know each step we made.
Q: What is the guarantee?
A: Generall 1-2 years, when the guarantee period ends up, we are responsible for life-long maintenance and would charge some fees concerning costs.
Q: What is the standard of package? 
A: Export standard package or special package according to customer requirement
Q:What is your payment term?
A:All terms of payment is acceptable.