China Oil Immersed Electric Power Transformer, Find details about China Oil-Immersed, High-Pressure from Oil Immersed Electric Power Transformer
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (kw) | load Loss (kw) 75ºC | No-load current (%) | Short- circuit impedance (%) | |
HV(KV) | LV(KV) | ||||||
6300 | 110± 8×1.25% | 6.3 6.6 10.5 11 | YNd11 | 10.0 | 36 | 0.80 | 10.5 |
8000 | 12.0 | 45 | 0.80 | ||||
10000 | 14.2 | 53 | 0.74 | ||||
12500 | 16.8 | 63 | 0.74 | ||||
16000 | 20.2 | 77 | 0.69 | ||||
20000 | 24.0 | 93 | 0.69 | ||||
25000 | 28.4 | 110 | 0.64 | ||||
31500 | 33.8 | 133 | 0.64 | ||||
40000 | 40.4 | 156 | 0.58 | ||||
50000 | 47.8 | 194 | 0.58 | ||||
63000 | 56.8 | 234 | 0.52 |
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (kw) | load Loss (kw) 75ºC | No-load current (%) | Short- circuit impedance (%) | ||
HV(KV) | MV(KV) | LV(KV) | ||||||
6300 | 110± 8×1.25% | 35 37 38.5 | 6.3 6.6 10.5 11 | YNyn0d11 | 12.0 | 47 | 0.95 | H-M 10.5 H-L 17.5-18.5 M-L 6.5 |
8000 | 14.4 | 56 | 0.95 | |||||
10000 | 17.1 | 66 | 0.89 | |||||
12500 | 20.2 | 78 | 0.89 | |||||
16000 | 24.2 | 95 | 0.84 | |||||
20000 | 28.6 | 112 | 0.84 | |||||
25000 | 33.8 | 133 | 0.78 | |||||
31500 | 40.2 | 157 | 0.78 | |||||
40000 | 48.2 | 189 | 0.73 | |||||
50000 | 56.9 | 225 | 0.73 | |||||
63000 | 67.7 | 270 | 0.67 | |||||
1. 10 type products: no-load loss fell by 10 percent; Load loss by 5 per cent. 2. 11 type products: no-load loss dropped 20%; Load loss by 5 per cent. |
Rated Capacity (kVA) | Voltage Combined | Vector- group | Step-up Combination | Step-down Combination | Short- circuit impedance | |||||||
HV(KV) | MV(KV) | LV(KV) | No-load Loss (kw) | load Loss (kw) 75ºC | No-load current (%) | No-load Loss (kw) | load Loss (kw) 75ºC | No-load current (%) | Step-up | Step-down | ||
31500 | 220± 2×2.5% 242± 2×2.5% | 115 121 | 6.6 10.5 11 35 37 38.5 | YNa0d11 | 25 | 117 | 0.57 | 22 | 99 | 0.50 | H-M 12-14 H-L 8-12 M-L 14-18 | H-M 8-10 H-L 28-34 M-L 18-24 |
40000 | 29 | 144 | 0.57 | 26 | 121 | 0.50 | ||||||
50000 | 34 | 170 | 0.50 | 30 | 144 | 0.43 | ||||||
63000 | 40 | 201 | 0.50 | 36 | 171 | 0.43 | ||||||
90000 | 50 | 276 | 0.43 | 46 | 234 | 0.36 | ||||||
120000 | 10.5 11 13.8 15.75 18 35 37 38.5 | 62 | 340 | 0.43 | 56 | 288 | 0.36 | |||||
150000 | 73 | 405 | 0.36 | 66 | 342 | 0.33 | ||||||
180000 | 84 | 463 | 0.36 | 76 | 387 | 0.33 | ||||||
240000 | 99 | 595 | 0.33 | 89 | 504 | 0.25 |
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (kw) | load Loss 75ºC(kw) | No-load current (%) | Short- circuit impedance (%) | |
HV(KV) | LV(KV) | ||||||
31500 | 220± 8×1.25% | 6.3 6.6 10.5 11 35 37 38.5 | YNd11 | 38 | 135 | 0.70 | 12-14 |
40000 | 45 | 157 | 0.63 | ||||
50000 | 54 | 189 | 0.56 | ||||
63000 | 63 | 220 | 0.56 | ||||
90000 | 80 | 288 | 0.49 | ||||
120000 | 10.5 11 35 37 38.5 | 99 | 346 | 0.49 | |||
150000 | 116 | 405 | 0.42 | ||||
180000 | 135 | 468 | 0.42 | ||||
120000 | 66 69 | 102 | 355 | 0.49 | |||
150000 | 120 | 415 | 0.42 | ||||
180000 | 140 | 475 | 0.42 |
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (kw) | load Loss (kw) 75ºC | No-load current (%) | Capacity assignment(%) | Short- circuit impedance (%) | ||
HV(KV) | MV(KV) | LV(KV) | |||||||
31500 | 220± 8×1.25% | 69 115 121 | 6.3 6.6 10.5 11 35 37 38.5 | YNyn0d11 | 44 | 162 | 0.77 | 100/100/100 100/50/100 100/100/50 | H-M 12-14 H-L 22-24 M-L 7-9 |
40000 | 52 | 189 | 0.70 | ||||||
50000 | 60 | 225 | 0.63 | ||||||
63000 | 70 | 261 | 0.63 | ||||||
90000 | 10.5 11 35 37 38.5 | 92 | 351 | 0.56 | |||||
120000 | 115 | 432 | 0.56 | ||||||
150000 | 135 | 513 | 0.49 | ||||||
180000 | 156 | 630 | 0.49 | ||||||
240000 | 193 | 780 | 0.45 |
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (kw) | load Loss (kw) 75ºC | No-load current (%) | Capacity assignment(%) | Short- circuit Impedance (%) | ||
HV(KV) | MV(KV) | LV(KV) | |||||||
31500 | 220± 8×1.25% | 115 121 | 6.3 6.6 10.5 11 35 37 38.5 | YNa0d11 | 25 | 108 | 0.56 | 100/100/50 | H-M 8-10 H-L 28-34 M-L 18-24 |
40000 | 30 | 132 | 0.56 | ||||||
50000 | 36 | 157 | 0.49 | ||||||
63000 | 42 | 189 | 0.49 | ||||||
90000 | 10.5 11 35 37 38.5 | 51 | 247 | 0.42 | |||||
120000 | 64 | 307 | 0.42 | ||||||
150000 | 76 | 365 | 0.35 | ||||||
180000 | 85 | 419 | 0.35 | ||||||
240000 | 104 | 540 | 0.30 | ||||||
1. 10 type products: no-load loss fell by 10 percent; Load loss by 5 per cent. 2. 11 type products: no-load loss dropped 20%; Load loss by 5 per cent. |
Q: What certificates and standard does your company have? |
A: Our factory has ISO9001:2008, ISO14001:2004, OHSAS18001:2007 certificates. We can send products to appointed laboratories for testing if necessary. |
Q: How long is your delivery time? |
A:For 10KV distribution transformer, the production cycle of our factory is 20~25 days. |
Q: What is your service? |
A: we have quick response in before sales period help you got order, and excellent service in production time let you know each step we made. |
Q: What is the guarantee? |
A: Generall 1-2 years, when the guarantee period ends up, we are responsible for life-long maintenance and would charge some fees concerning costs. |
Q: What is the standard of package? |
A: Export standard package or special package according to customer requirement |
Q:What is your payment term? |
A:All terms of payment is acceptable. |