China 16FT 18FT 20FT 24FT, Hvls Fans, Workshop Fan, Warehouse Fan, Ceiling Fan, Find details about China 7.3m Fan, Hvls Fan from 16FT 18FT 20FT 24FT, Hvls Fans, Workshop Fan, Warehouse Fan, Ceiling Fan
Model No. | Fan ID m | Pole length m | Motor Power kw | Blades pcs | Air volume m3/min | Max speed rpm | Fan weight kgs |
HVLS-FD1A24 | 2.45 | 0.6 | 0.9 | 5 | 7500 | 150 | 62 |
HVLS-FD1A30 | 3.05 | 0.6 | 0.9 | 5 | 8600 | 140 | 67 |
HVLS-FD1A36 | 3.66 | 0.6 | 0.9 | 5 | 9900 | 120 | 71 |
HVLS-FD1A42 | 4.26 | 1 | 0.9 | 5 | 10700 | 100 | 75 |
HVLS-FD1A49 | 4.9 | 1 | 0.9 | 5 | 11700 | 87 | 79 |
HVLS-FD1A55 | 5.5 | 1 | 0.9 | 5 | 12600 | 78 | 83 |
HVLS-FD1A61 | 6.1 | 1 | 1.5 | 6 | 14300 | 70 | 103 |
HVLS-FD1A73 | 7.3 | 1 | 1.5 | 6 | 15500 | 65 | 110 |
Fan size (D) | 24ft/ 7.3m |
No of blades; | 6 |
Fan blade width(W) | 187mm |
Blade material | Aluminium alloy (aeronautical aluminium) |
Max speed | 65RPM | Speed range 20-65rpm |
Maximum wind pressure (static pressure) | >20Pa | Related to installation environment and speed |
Air volume | 7500m3/min @16Pa | The volume of air at a reference static pressure |
Applying space 1 | >2000m2 Blade plane height≥11m 65rpm | Comfort index characteristic |
Applying space 2 | >1500m2 Blade plane height≥8m 62rpm | Comfort index characteristic |
Applying space 3 | >1300m2 Blade plane height≥6m 55rpm | Comfort index characteristic |
Applicable space height(H) | 8-18 m | Effective floor height inside the building |
Maximum speed noise | <60db@65rpm | Related to the fan installation environment |
Half speed noise | <45db@33rpm | Related to the fan installation environment |
Fan Total Weight | 110kg | |
Motor weight | 32.5kg | |
Sling weight | 20kg | Related to the length of the mounting boom |
Blade weight | 57.5kg | |
Max torque | 230Nm@65rpm | |
Max lift force | 225N@65rpm |
Motor rated power | 1.5Kw |
Ambient Temp | 10-50ºC |
Rated Voltage/Rated Current1 | 3Phase 380-440Vac/2.8A |
Rated Voltage/Rated Current 2 | 3Phase 220-240Vac/4.9A |
Fixed mode | Concrete roof beams or steel frames | Two types of fixed splint |
boom length | ≤3m | The length of the boom depends on the strength design |
Install interval(S) | 4D>S>6D | Two sets of fan installation interval |
installation space h1 | >1/4D | The distance of fan-blade plane from the roof |
installation spaceh2 | >D | The height of the flat blade plane from the ground |
Horizontal safe distance | >1/4D | Reduction in distance may increase in noise |
Vertical safety distance | >1/4D | The vertical distance between the highest point of the obstacle and the blade |