China Intrinsic Safe 2-Wire Accurate Absolute Gauge 4~20madc Customized Air Differential Pressure Sensor, Find details about China Wastewater Treatment, 4-20mA Differential Silicon from Intrinsic Safe 2-Wire Accurate Absolute Gauge 4~20madc Customized Air Differential Pressure Sensor
Electric Performance
1. Power supply: ≤ 2.0mADC; ≤10V DC
2. Electric connection: 100mm silicon rubber flexible wires
3. Common mode voltage input: 50% of input (typ. )
4. Input impedance: 3kΩ ~8kΩ
5. Output impedance: 3.5kΩ ~6kΩ
6. Response (10%~90%): <1ms
7. Insulation resistor: 100MΩ , 100VDC
8. Overpressure: To see Order Guide
9. Max. Static pressure: 20MPa
10. Zero drift/static pressure: ≤ 0.5mV/MPa
Construction Specification
1. Diaphragm material: Stainless steel 316L
2. Housing: Stainless steel 316L
3. Pin: Silicon rubber flexible wire
4. O-ring: Viton
5. Net weight: ~36g
Basic Condition
1. Media temperature: (25± 1)° C
2. Environment temperature: (25± 1)° C
3. Shock: 0.1g (1m/s/s) Max.
4. Humidity: (50%± 10%)RH
5. Local air pressure: (86~106)kPa
6. Power supply: (1.5± 0.0015)mADC
Specification
Dimension