China AWG 14 K Type Thermocouple Compensating / Compensation Cable FEP Insulation, Find details about China Thermocouple Compensating Cable, K Type Thermocouple Compensating Cable from AWG 14 K Type Thermocouple Compensating / Compensation Cable FEP Insulation
Type K Thermocouple Bare Wire
Type K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures.
1. Chemical Composition
Material | Chemical composition (%) | ||||
Ni | Cr | Si | Mn | Al | |
KP(Chromel) | 90 | 10 | |||
KN(Alumel) | 95 | 1-2 | 0.5-1.5 | 1-1.5 |
2. Physical properties and Mechnical properties
Material | Density(g/cm3) | Melting point(ºC) | Tensile Strength(Mpa) | Volume resistivity(μΩ.cm) | Elongation rate (%) |
KP(Chromel) | 8.5 | 1427 | >490 | 70.6(20ºC) | >10 |
KN(Alumel) | 8.6 | 1399 | >390 | 29.4(20ºC) | >15 |
3. EMF Value range at different temperature
Material | EMF value Vs Pt(μV) | |||||
100ºC | 200ºC | 300ºC | 400ºC | 500ºC | 600ºC | |
KP(Chromel) | 2816~2896 | 5938~6018 | 9298~9378 | 12729~12821 | 16156~16266 | 19532~19676 |
KN(Alumel) | 1218~1262 | 2140~2180 | 2849~2893 | 3600~3644 | 4403~4463 | 5271~5331 |
EMF value Vs Pt(μV) | ||||
700ºC | 800ºC | 900ºC | 1000ºC | 1100ºC |
22845~22999 | 26064~26246 | 29223~29411 | 32313~32525 | 35336~35548 |
6167~6247 | 7080~7160 | 7959~8059 | 8807~8907 | 9617~9737 |
Type K Extension Cable Chromel / Alumel Material FEP insulation
Specifications
1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.
Thermocouple variety and index
Thermocouple Variety and Index | ||
Variety | Type | Measurement Range(°C) |
NiCr-NiSi | K | -200-1300 |
NiCr-CuNi | E | -200-900 |
Fe-CuNi | J | -40-750 |
Cu-CuNi | T | -200-350 |
NiCrSi-NiSi | N | -200-1300 |
NiCr-AuFe0.07 | NiCr-AuFe0.07 | -270-0 |
3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire
Dimensions / Tolerance mm ) : 4.0+-0.25
Color code & initial calibration tolerances for thermocouple wire:
Thermocouple Type | ANSI Color Code | Initial Calibration Tolerances | ||||
Wire Alloys | Calibration | +/- Conductor | Jacket | Temperature Range | Standard Limits | Special Limits |
CHROMEL(+) vs. ALUMEL(-) | K | Yellow/Red | Brown | -200°C to -110°C -110°C to 0°C 0°C to +285°C 285°C to +1250°C | ± 2% ±2.2°C ±2.2°C ± .75% | ±1.1°C ± .4% |
Color Code & Initial Calibration Tolerance for Extension Wire:
Extension type | ANSI Color Code | Initial Calibration Tolerances | ||||
Wire Alloys | Calibration | +/- Conductor | Jacket | Temperature Range | Standard Limits | Special Limits |
Iron (+) vs. Constantan(-) | JX | White/Red | Black | 0°C to +200°C | ±2.2°C | ±1.1°C |
CHROMEL (+) vs. ALUMEL (-) | KX | Yellow/Red | Yellow | 0°C to +200°C | ±2.2°C | ±1.1°C |
Copper(+) vs. Constantan(-) | TX | Blue/Red | Blue | -60°C to +100°C | ±1.1°C | ± .5°C |
CHROMEL(+) vs. Constantan(-) | EX | Purple/Red | Purple | 0°C to +200°C | ±1.7°C | ±1.1°C |
PVC-PVC Physical Properties:
Characteristics | Insulation | Jacket |
Abrasion Resistance | Good | Good |
Cut Through Resistance | Good | Good |
Moisture Resistance | Excellent | Excellent |
Solder Iron Resistance | Poor | Poor |
Service Temperature | 105ºC continuous 150ºC single | 105ºC continuous 150ºC single |
Flame Test | Self-extinguishing | Self-extinguishing |