Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

China Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm, Find details about China Fire Alarm Cable, PVC Cable from Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

Model NO.
medium voltage cable
Sample
Available and Free of Charge
Standards
IEC, ASTM, BS
Packing
All Wooden Drum, Iron-Wooden Drum, All Iron Drum
Conductor Material
Aluminum
Trademark
Jinshui
Origin
Henan, China (Mainland)
Model NO.
medium voltage cable
Sample
Available and Free of Charge
Standards
IEC, ASTM, BS
Packing
All Wooden Drum, Iron-Wooden Drum, All Iron Drum
Conductor Material
Aluminum
Trademark
Jinshui
Origin
Henan, China (Mainland)

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

Product Display

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm


Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

 

Function and characteristics:

 

(1).The long-time permissible operation temperture of conductor shall not be higher than 70oC.

(2).Conductor maximum short circuit(not more than 5 seconds)temperature shall not be higher than 160 oC.

(3).The power cable is not limited by drop in level when being laid,and the ambient temperature shall not be lower than 0 oC.

(4).Perfect chemical stability,resistant against acids,alkalis,grease and organic solvents,and flame.

(5).Light weight,perfect bending properties,installed and maintained easily and conveniently.

 

1.Product Performance
(1).The long-time permissible operation temperture of conductor shall not be higher than 70oC.
(2).Conductor maximum short circuit(not more than 5 seconds)temperature shall not be higher than 160 oC.
(3).The power cable is not limited by drop in level when being laid,and the ambient temperature shall not be lower than 0 oC.
(4).Perfect chemical stability,resistant against acids,alkalis,grease and organic solvents,and flame.
(5).Light weight,perfect bending properties,installed and maintained easily and conveniently.
Voltage rating:0.6/1kV3.6/6kV.
Conductors:copper or aluminum.
Number of cable cores:one core(Single core),two cores(Double cores),three cores,four cores(Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),five cores(Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).We provide armoured trpe and non-armored type for the power cables above.
Our company has been carrying out Chinese national standard GB 12706 and GB 12666.6(equivalent to IEC 60502 and IEC 60331)for PVC insulated power cable and fire resistant cable needed by domestic customer,and for foreign customers we can manufacture in accordance with BS,DIN and other countries,standards.In addition,we can design and manufacture PVC insulated power cable with special characteristics according to needs of customers.

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

Technical Requirements

 

Cu Core

AL Core

Description

VV

VH-VV

VLV

NH-VLV

Cu(Al)Core PVC Insulated PVC Sheathed Power Cable

Cu(Al)Core PVC Insulated PVC Sheathed Fire Resistant Cable

VY

NH-VY

VLY

NH-VLY

Cu(Al)Core PVC Insulated PE Sheathed Power Cable

Cu(Al)Core PVC Insulated PE Sheathed Fire Resistant Cable

VV22

NH-VV22

VLV22

NH-VLV22

Cu(Al)Core PVC Insulated Steel Tape Armored PVC Sheathed Power Cable

Cu(Al)Core PVC Insulated Steel Tape Armored PVC Sheathed Fire Resistant Cable

VV23

NH-VV23

VLV23

NH-VLV23

Cu(Al)Core PVC Insulated Steel Tape Armored PE Sheathed Power Cable

Cu(Al)Core PVC Insulated Steel Tape Armored PE Sheathed Fire Resistant Cable

VV32

NH-VV32

VLV32

NH-VLV32

Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Power Cable

Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Fire Resistant Cable

VV33

NH-VV33

VLV33

NH-VLV33

Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Power Cable

Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Fire Resistant Cable

VV42

VH-VV42

VLV42

NH-VLV42

Cu(Al)Core PVC Insulated Thick Steel Wire Armored PVC Sheathed Power Cable

Cu(Al)Core PVC Insulated Thick Steel Wire Armored PVC Sheathed Fire Resistant Cable

VV43

VH-VV43

VLV43

NH-VLV43

Cu(Al)Core PVC Insulated Thick Steel Wire Armored PE Sheathed Power Cable

Cu(Al)Core PVC Insulated Thick Steel Wire Armored PE Sheathed Fire Resistant Cable

 

Nominal Cross-Section AreaofConductor Core

 

Master Core

2.5

4

6

10

16

25

35

50

70

95

120

150

185

3+1Neutral Core

1.5

2.5

4

6

10

16

16

25

35

50

70

70

95

3+2Neutral Core

1.5

2.5

4

6

10

16

16

25

35

50

70

70

95

4+1Neutral Core

1.5

2.5

4

6

10

16

16

25

35

50

70

70

95

 

Nominal Thickness of Insulation

Cross Section(mm2)/KV

1

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

0.6/1

0.8

0.8

0.8

1

1

1

1

1.2

1.2

1.4

1.4

1.6

1.6

1.8

2.0

3.6/6

 -

-

-

-

-

3.4

3.4

3.4

3.4

3.4

3.4

3.4

3.4

3.4

3.4

 

DC Resistance of Insulation(mm)

Nominal section Area

(mm2)

Resistance not More than

(Ω/km)

Nominal section Area

(mm2)

Resistance not More than

(Ω/km)

Resistance not More than

(Ω/km)

Nominal section Area

(mm2)

Resistance not More than

(Ω/km)

 

Cu

Al

 

Cu

Al

Cu

Al

 

Cu

Al

1.5

12.1

18.1

25

0.727

1.20

0.124

0.206

630

0.0283

0.0469

2.5

7.41

12.1

35

0.524

0.868

0.0991

0.164

800

0.0221

0.0369

4

4.61

7.41

50

0.387

0.641

0.0754

0.125

1000

0.0176

0.0291

6

3.08

4.61

70

0.268

0.443

0.0601

0.100

-

-

-

10

1.83

3.08

90

0.193

0.320

0.0470

0.0778

-

-

-

16

1.15

1.91

120

0.153

0.253

0.0366

0.0605

-

-

-

 

 
Related Product

 

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

Application

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

Overhead bare conductor has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

Company Information

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

Jinshui Wire & Cable Group

is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management System ,ISO 14001 Environmental Management System ,OHSAS18001 occupational Heath Management System ,ISO 10012 Measurement Management System and others from China and abroad.

We have been engaged in producing electric cable and wire for nearly 20 years, and  we are also 12 year gold supplier in alibaba. And we are confident that we can offer the best service and quality for you.

 

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm
Exhibition

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

FAQ

Flame Retardant Low Voltage Electrical Power Cable Copper Conductor PVC Insulated Cable 4 Core 25mm

1. Are  you the factory or trading company?
We are the manufacturer and 13 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.

2. When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.

3. How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freightcharge should be paid.

4. What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .

5. What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.