500/5A Split Core CT Current Transformer

China 500/5A Split Core CT Current Transformer, Find details about China Current Transformer Split, 500/5A Split Core CT from 500/5A Split Core CT Current Transformer

Model NO.
LZCK350-10
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Accuracy Class
0.5%, 1%
Key Words
CT Current Transformer
Key Word
500/5A Split Core CT
Rated Primary Current
20-600A
Rated Load
≤25va
Rated Frequency
50Hz or 60Hz
Rated Secondary Current
5A or 1A
Model
Current Transformer Split
Weight (Kg)
3.1
Color
Black or Customized
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
φ 50xφ 110x52
Origin
Beijing, China
Model NO.
LZCK350-10
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Accuracy Class
0.5%, 1%
Key Words
CT Current Transformer
Key Word
500/5A Split Core CT
Rated Primary Current
20-600A
Rated Load
≤25va
Rated Frequency
50Hz or 60Hz
Rated Secondary Current
5A or 1A
Model
Current Transformer Split
Weight (Kg)
3.1
Color
Black or Customized
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
φ 50xφ 110x52
Origin
Beijing, China
Product Description
LZCK series split core current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-SafeRing/SafePlus...and cable distribution boxes.
The transformer can be directly installed at the inlet and outlet cables.The slice is imported silicon material. The semicircular ring core and secondary windings are vacuum poured by insulated resin.
Parameters
Technical parameters 
StandardsIEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current20-600A
Rated load≤25VA
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current120%I1n
Secondary winding power-frequency voltage3kV, 1min
Instrument security factorFS≤10
Mechanical parameters
Dimensions (W×D×H) (mm)φ50xφ110x105
Weight (kg)3.1
Operating conditions
Operating temperature-35°C to +55°C
Daily average temp<+40°C
Altitude<3500 meters
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.
TECHNICAL DATA
TypeLZCK350-10LZCK350-10LZCK350-10
PurposeMeasuring current transformerProtection current transformerDouble winding current transformer
RatioAccuracy class and rated burden(VA)Accuracy class and rated load (VA)Composite accuracy class and rated load (VA)
I1/I20.51310P1510P1010P50.5110P1010P5
20/1  0.5  0.75    
30/1 0.51.5 0.751.25    
50/1 12 1.252    
75/122.53.751.2523 212
100/12.53.75522.5522.51.52.5
200/15  357.52.5 2 
300/110  357.53.75 2.5 
400/110  35105 2.5 
500/125  3.756.25105 2.5 
600/125  57.5107.5 5 
50/5  2.5  2    
75/5  2.5  3    
100/52.5 3.75  5 2.5 2.5
200/57.5     2.55 2.5
300/510     5 22.5
400/515     7.5 2.55
500/525     7.5 2.55
600/530     10 37.5