China 20A 14VDC Power Relay for Intelligent Meters, Find details about China Relays, Solid State Relays from 20A 14VDC Power Relay for Intelligent Meters
Contact Form | 1A 1C |
Rated load | 20A 14VDC 5A 250VAC |
Max Switching Voltage | 250VAC/ 30VDC |
Max Switching Current | 20A |
Max Switching Capacity | 1250VA/280W |
Min Allowing load | 5VDC 100mA |
Contact Resistance | 100mΩ (at 6VDC 1A) |
Insulation Resistance | 100MΩ (at 500VDC) |
Withstand Voltage Between open contacts | 750VAC 1min |
Between coil and contacts | 750VAC 1min |
Withstand impact voltage | Between coil and contacts 4.5kv(1.2X50us) |
Operate Time | Max.10ms |
Release Time | Max.5ms |
Mechanical life | 10,000,000 ops ON/OFF = 0.1s/0.1s |
Electrical life | 50,000 ops ON/OFF=1s/9s |
Impact Resistance Misoperation Durability | 100m/s² Approx10G 1000m/s² Approx100G |
Vibration Resistance Misoperation Durability | 10 - 55 Hz 1.5mm Double Amplitude 10 - 55 Hz 1.5mm Double Amplitude |
Temperature Range | -40ºC to +85ºC |
Humidity | 5% to 90% |
Installation type | PCB Mounting |
Coil rated voltage | Operating voltage | Releasing Voltage | Coil rated Current (±10%) | Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75% rated voltage (initial) | above 5% rated voltage (initial) | 120mA | 41.7Ω | 600mW | 90-120 % Rated voltage |
DC 6V | 100mA | 60Ω | ||||
DC 9V | 66.7mA | 135Ω | ||||
DC 12V | 50mA | 240Ω | ||||
DC 15V | 40mA | 375Ω | ||||
DC 18V | 33.3mA | 540Ω | ||||
DC 24V | 25mA | 540Ω |
Coil rated voltage | Operating voltage | Releasing Voltage | Coil rated Current (±10%) | Coil resistance(±10%) | Rated consumed power | Allowing voltage |
DC 5V | Below 75% rated voltage (initial) | above 5% rated voltage (initial) | 72mA | 69.4Ω | 360mW | 90-120 % Rated voltage |
DC 6V | 30mA | 100Ω | ||||
DC 9V | 40mA | 225Ω | ||||
DC 12V | 30mA | 400Ω | ||||
DC 15V | 24mA | 625Ω | ||||
DC 18V | 20mA | 900Ω | ||||
DC 24V | 5mA | 1600Ω |