5 HP 10HP Plastic Industrial Air Cooled Water Chiller for Blow Molding
For plastic chillers, there are air cooled chillers and water cooeld chillers.Both water chillers are commonly used in plastic process machines including injection molding machine, blowing machine, plastic extrusion, vacuum thermoforming machine, and other packing machines.
During the bottle blowing process, the preform need to be heated and stretched out inside the mold, then compressed air is then forced out in controlled low-pressure stages through the hollow ramrod. Then it's time to provide cold water to the mold , so that the plastic form is forced out to the sides of the mold, remains uniformly thin and strong.
Design of Plastic chiller(1). Electrical waterproof IP55 grade, chiller could be placed outdoor without shelter.
(2) Design working condition ambient temperature from -20C degree to +50C degree.
(3). Working condition: good air circulation place to discharge the heat.
(4). Remote and local control available, chiller with stop/off function remote and alarm remote optional.
(5). Power off - Auto strart up turn on function supported.
(6). Inlet and outlet pipe stainless steel;
Technical Features5 HP 10HP Plastic Industrial Air Cooled Water Chiller for Blow Molding
1.No refurbished , new and original scroll type compressors, famous brand Copeland, Danfoss, and Panasonic, built in multi safety protection, low noise, energy saving and stable.
2. Adpopt Schneider, Siemens, ABB electrical components, featuring stability and long service life.
3. Italian oil pump with big flow, low power to save energy, high efficiency and durability.
4. Imported precise digital temperature controller with LCD display, controlling the water temperature as accurate as ±1ºC . Auto test and analysis function by displaying working condition in English for easy operation and monitoring.
5. Stainless steel buffer tank is available, and built in auto filling water devices, convenient for clean and maintenance.
6. High efficiency shell and tube type evaporator, to cool tank outside.
7.Air cooled industrial chiller equipped with finned copper by the warped and ranked copper pipe, to release the heat into air to cool down the coolant temperature.
8.Optional environmental protection refrigerant R404A, R134a, R407c, R410a
9.Customized chiller with special power supply voltage.
10. Outlet water temperature 5 deg C to 30deg C, high precision to ±1 deg C.


Technical Specification for Air Cooled Hydraulic Oil Chiller
5 HP 10HP Plastic Industrial Air Cooled Water Chiller for Blow Molding
Air cooled scroll water chiller 5deg C~ 30deg C |
Model | MG-5C | MG-10C(D) | MG-12C(D) | MG-15C(D) | MG-20C(D) | MG-25C(D) | MG-30C(D) | MG-40C(D) |
Cooling capacity | Kcal/h | 11266 | 24510 | 26660 | 35948 | 47558 | 54352 | 71896 | 94256 |
KW | 13.1 | 28.5 | 31 | 41.8 | 55.3 | 63.2 | 83.6 | 109.6 |
Tons | 3.72 | 8.10 | 8.81 | 11.89 | 15.72 | 17.97 | 23.77 | 31.16 |
Input power | kW | 5.61 | 10.83 | 12.53 | 16.31 | 21.27 | 24.35 | 32.33 | 41.66 |
Outlet water temperature | 5°C -35°C |
Power supply | 3PHASE-220/380V/415v/460v-50HZ/60HZ |
Refrigerant | Type | R22/R407C/R410A |
Control type | Thermostatic expansion valve |
Compressor | Type | Hermetic Scroll Type |
Power(kw) | 4.54 | 4.54*2 | 5.4*2 | 4.54*3 | 9.05*2 | 10.6*2 | 9.05*3 | 9.05*4 |
Evaporator | Type | Stainless Steel Tank with Coil type or Shell and tube |
Water flow(m³/h) | 2.25 | 4.89 | 5.31 | 7.17 | 9.48 | 10.83 | 14.33 | 18.79 |
Capacity(Lts) | 70 | 200 | 200 | 270 | 350 | 350 | 450 | 580 |
Fitting pipe(mm) | DN25 | DN32 | DN32 | DN40 | DN40 | DN40 | DN65 | DN65 |
Condenser | Type | Finned Copper tube +low noise air fans |
Air volume(m³/h) | 5000 | 10000 | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 |
Water pump | Power(kw) | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 3 |
Lift(m ) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Dimension | L(mm) | 1300 | 1560 | 1560 | 1800 | 2100 | 2100 | 2500 | 2350 |
W(mm) | 650 | 850 | 850 | 1000 | 1000 | 1000 | 1200 | 1460 |
H(mm) | 1200 | 1500 | 1500 | 1600 | 1700 | 1700 | 1800 | 2000 |
Weight | KG | 200 | 450 | 500 | 750 | 850 | 900 | 1150 | 1350 |
NOTE 1.Normal conditions:Chilled water inlet temp is 12ºC,outlet temp is 7ºC,Ambient temp35ºC; 2.Temperature condtion:Chillerd water range is 7ºC--30ºC,This series of unit requires the chient to use the liquid with the freezing point below the required temperature as the refrigerant. 3.Input power:3P-380V-50HZ,Allowable buctuate voltage:±10%.Allowable voltage difference in phase:±2% 4.Actual head lift is pump head lift minus the machine internal head loss(1mH2O=9.8KPa); 5.The above parameters are based are Refrigerant R22,for other parameters of Refrigerant R134A,R407C ect.refrigerants,plcontact us. 6.Due to technology updating, size meters listed data may change;The above datas are for reference only,please feel free to contact us for the latest data. |
5 HP 10HP Plastic Industrial Air Cooled Water Chiller for Blow Molding


Working Site and Application Industry
MGREENBELT Water Chiller are widely used in the Plastic industry, Electrons, Plating, Chemical Industry,Food and beverage, Ultrasonic wave cooling, Printing and other industrial production. It can precisely control the exactly temperature , which requested by the modernized machinery production, and greatly improved the production efficiency and product quality. MGREENBELT Industrial chiller is a good partner for the modernized industry , which feather as easy to operate with reasonable design, high quality and complete range of specifications.
1)Plastics industry chiller
2)Electronic industry chiller
3)Electroplating industry chiller
4)Mechanical industry chiller
5)Building industry chiller
6)Vacuum coating chiller
7)Food industry chiller
8)Chemical fiber industry chiller
9)Beverage industry chiller
Our Company and Factory
MGREENBELT Industrial Water ChillersOur Product Range
(1).The Temperature Range:-40ºC to +35ºC.
(2).Cooling Capacity Range: 2 RT to 500RT / 7 kw to 1750kw / 6020Kal to 1505000Kal
(3). The Refrigerant: R22/R404a/R134a/R507c.
(4). We can also produce the chiller according to your requirements
FAQ1. Are you manufacturer or Trade Company?
We are OEM professional factory, founded in 2003.
2. What's the order process?
.Inquiry---provide us all clear requirements.
.Quotation---quotation form with all clear specifications.
.Contract confirmation---provide correct contract details.
.Payment terms--- T/T 30% in advanced, balanced before shipment.
.Production---mass production
. Pressure keeping with Nitrogen--- 72 hours
.Testing: 8hours, to ensure the quality of the machine
.Shipping--- by sea, train, air or courier. Detailed picture of package will be provided.
.Installation
3.What terms of payment you use?
T/T, L/C,etc.
4. How to get a prompt quotation?
When you send the inquiry to us, pls kindly send it with below technical information.
1)water chiller type: Air cooled or water cooled
2)Cooling capacity: _____ Kcal/hr or _____KW
3)Refrigerant: R407c, R410A or others
4) Voltages and Frequency : ______V/PH/HZAs a professional industrial chiller manufactuer and solution provider , we can supply kinds of chillers to meet your different cooling requirement, if the chillers above is not workable for you, please feel free send needs to us directly.
Libra Zhang, Mobile: 0086 18769762328