Dlo, Diesel Locomotive Cable, 2 Kv, 1/C, Cu/Epr/CPE (ICEA S-95-658/NEMA WC70/UL 44/CSA C22.2 No. 38)

China Dlo, Diesel Locomotive Cable, 2 Kv, 1/C, Cu/Epr/CPE (ICEA S-95-658/NEMA WC70/UL 44/CSA C22.2 No. 38), Find details about China Power Cable, XLPE Cable from Dlo, Diesel Locomotive Cable, 2 Kv, 1/C, Cu/Epr/CPE (ICEA S-95-658/NEMA WC70/UL 44/CSA C22.2 No. 38)

Model NO.
DLO
Wire Core Material
Tinned Wire
Certification
ISO, CCC
Model
Dlo
Brand
Boan
Manufacture Standard
Icea S-95-658/NEMA Wc70/UL 44/CSA C22.2 No. 38
Rated Voltage
2 Kv
Number of Cores
1
Section
14 AWG-1000 Mcm
Trademark
DingAn
Specification
SGS
Origin
Jiangsu Yixing, China
HS Code
8544601200
Model NO.
DLO
Wire Core Material
Tinned Wire
Certification
ISO, CCC
Model
Dlo
Brand
Boan
Manufacture Standard
Icea S-95-658/NEMA Wc70/UL 44/CSA C22.2 No. 38
Rated Voltage
2 Kv
Number of Cores
1
Section
14 AWG-1000 Mcm
Trademark
DingAn
Specification
SGS
Origin
Jiangsu Yixing, China
HS Code
8544601200
DLO, Diesel Locomotive Cable, 2 KV, 1/C, Cu/EPR/CPE (ICEA S-95-658/NEMA WC70/UL 44/CSA C22.2 No. 38)
Features
Cable is Listed RHH/RHW-2 per UL, and Listed RW90/R90 per CSA. Jacket is rated Oil Resistance I or II rated per UL 44. All sizes meet VW-1 flame test. Type RHH/RHW-2 is rated Sun Resistance For CT use, 1/0 AWG and larger. Type RW90/R90 is rated -40 °C and FT4. Meets vertical flame tests. 

Application
As power cable used in DLO Locomotive Cable, railroad and transit car wiring where high reliability is required. Also suitable for use in static and dynamic wind power applications. For portable and fixed installations leads for motors, generators, batteries.

Standards
UL 44
Rubber Insulated Wires and Cables.
CSA C22.2 No. 38
Thermoset Insulated Wires and Cables.
ICEA S-95-658/NEMA WC70
Nonshielded 0 - 2000 V Cables.

Specifications
Maximum operating voltage: 2000 volts
Maximum conductor operation temperatures: 90 °C wet and dry locations

Engineering Information
1. Conductor: Soft annealed tinned coated copper conductor, flexible stranding per AAR RP-588, and ASTM B3, B172, B174 as applicable. On request, uncoated copper wires.
Sizes: 14 AWG - 1111 kcmil.
2. Separator: A suitable opaque tape, as required.
3. Insulation: Flame retardant thermoset ethylene propylene rubber (EPR), meeting the requirements of UL 44.
4. Jacket: Black flame retardant thermoset chlorinated polyethylene (CPE) jacket, meeting the
requirements of UL 44.
Conductor SizeNumber of StrandsSize of Each StrandInsulation Thickness Jacket ThicknessMaximum Overall DiameterApproximate Total Weight
AWG or kcmil
AWGmilmilinlb/kft
14192745250.2233.00
12192545300.2546.00
1027244530.000.2865.00
8372460300.3391.00
6632460300.39136.00
41052460300.45201.00
21542460300.51274.00
12242480450.65419.00
1/02732480450.69492.00
2/03232480450.74575.00
3/04262480450.83770.00
4/05512480450.89884.00
2636462495651.011114.00
3137792495651.081309.00
3749312495651.141528.00
44411102495651.221785.00
535133224110651.332140.00
646159124110651.422546.00
778195224110651.533017.00
929231824110651.643529.00
1111274524125951.854291.00